Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38563720

RESUMO

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

2.
Adv Exp Med Biol ; 788: 293-300, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23835990

RESUMO

Diisocyanate-induced asthma is difficult to diagnose since the immunopathological mechanisms and exposure determinants at the workplace are not well defined. The aim of this study was to evaluate the non-invasive methods of nasal lavage fluid (NALF) and induced sputum (IS) to enhance the diagnostic efficiency. Sixty-three diisocyanate-exposed workers with work-related shortness of breath underwent a standardized 4-steps-1-day-whole body exposure test with diisocyanates used at work up to 30 ppb. NALF and IS were collected before, 0.5, and 19 h after the end of exposure. Cellular composition and soluble inflammatory biomarkers were studied in the samples. In addition, ten controls with bronchial hyperresponsiveness, but without prior occupational diisocyanate exposure, were also examined. Twelve out of the 63 subjects (19 %) showed a significant asthmatic reaction (pulmonary responders) after challenge (FEV1 decrease >20 %). NALF samples did not demonstrate significant effects either on cellular composition or on mediator concentrations in the responders, non-responders, or controls at any time point. In contrast, in the IS samples of the pulmonary responders collected 19 h after challenge, the percentage of eosinophils was higher (p = 0.001) compared with baseline before challenge. Eosinophils were also increased 30 min and 19 h after challenge in IS samples of the responders compared with the non-responders or controls. In addition, 19 h after challenge the eosinophilic cationic protein (ECP) concentration was significantly higher in the responders than non-responders (p < 0.04) or controls (p < 0.002). In conclusion, positive asthmatic reactions to diisocyanates are accompanied by an influx of eosinophils into lower airways. Analysis of induced sputum should be implemented in the diagnostic procedure of diisocyanate-related airway diseases.


Assuntos
Asma/induzido quimicamente , Asma/diagnóstico , Testes de Provocação Brônquica/métodos , Isocianatos/efeitos adversos , Doenças Profissionais/induzido quimicamente , Doenças Profissionais/diagnóstico , Adulto , Biomarcadores/metabolismo , Brônquios/efeitos dos fármacos , Hiper-Reatividade Brônquica/imunologia , Proteína Catiônica de Eosinófilo/sangue , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Líquido da Lavagem Nasal , Exposição Ocupacional , Fumar , Fatores de Tempo
3.
Adv Exp Med Biol ; 755: 55-63, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22826049

RESUMO

Non-invasive methods to assess inflammation of lower airways are induced sputum (IS), exhaled nitric oxide (eNO), and exhaled breath condensate (EBC). Here we focused on the assessment of airway inflammation with a panel of non-invasive methods in health care workers (HCWs) with suspected latex allergy with and without current allergic respiratory symptoms about 10 years after the latex ban in German health care facilities. Seventy-seven non-smoking subjects were examined by skin prick test and specific IgE measurements, eNO, IS, and EBC. Sensitivity, specificity, and positive and negative predicted values for relevant biomarkers were calculated using current asthma symptoms as the gold standard. Twenty-nine subjects (38%) reported ongoing asthmatic symptoms (AS). In these subjects the EBC concentrations of nitrogen oxides (NO(x); p=0.027) and leukotriene B(4) (p=0.025) were significantly higher than in subjects without AS. In addition, in the subjects with AS the numbers of eosinophils (p=0.015) and the concentrations of IL-5 (p= 0.021) in IS samples were significantly higher than in the subjects without AS. A good correlation between several inflammatory markers in IS was detected. The maximum Youden Index was reached for IS total eosinophils ≥3.5·10(4) with a test efficiency of 0.72. In conclusion, non-invasive inflammatory monitoring with EBC and IS may assist the diagnosis of allergic asthma. Self-reported current asthmatic symptoms were reflected by eosinophilic inflammation and the best parameter to support the asthma diagnosis is a total number of eosinophils ≥3.5·10(4) in IS.


Assuntos
Asma/diagnóstico , Adulto , Testes Respiratórios , Feminino , Pessoal de Saúde , Humanos , Imunoglobulina E/sangue , Leucotrieno B4/análise , Masculino , Óxido Nítrico/análise , Testes Cutâneos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...