Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Vet Res ; 83(10)2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35905145

RESUMO

OBJECTIVE: To assess whether cardiac MRI or various biomarkers can be used to detect myocardial ischemia and fibrosis in dogs with cardiomegaly secondary to myxomatous mitral valve disease (MMVD). ANIMALS: 6 dogs with cardiomegaly secondary to naturally occurring stage B2 MMVD being treated only with pimobendan with or without enalapril and 6 control dogs with no cardiac disease. All dogs were ≥ 5 years old with no systemic illness. PROCEDURES: Serum cardiac troponin I and concentrations were measured, and dogs were anesthetized for cardiac MRI with ECG-triggered acquisition of native T1- and T2-weighted images. Gadolinium contrast was administered to evaluate myocardial perfusion and late gadolinium enhancement (LGE). Mean T1 and T2 values and regions of LGE were measured with dedicated software. Extracellular volume (ECV) was estimated on the basis of Hct and T1 values of myocardium and surrounding blood. Subjective analysis for myocardial perfusion deficits was performed. RESULTS: Dogs with MMVD had significantly (P = .013) higher cardiac troponin I concentrations than control dogs, but galectin-3 concentrations did not differ (P = .08) between groups. Myocardial fibrosis was detected in 4 dogs with MMVD and 3 control dogs; no dogs had obvious myocardial perfusion deficits. Native T1 and T2 values, postcontrast T1 values, and ECV values were not significantly different between groups (all P > .3). CLINICAL RELEVANCE: Results suggest that some dogs with cardiomegaly secondary to MMVD may not have clinically relevant myocardial fibrosis.


Assuntos
Doenças do Cão , Doenças das Valvas Cardíacas , Isquemia Miocárdica , Animais , Cardiomegalia/tratamento farmacológico , Cardiomegalia/veterinária , Meios de Contraste , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/etiologia , Cães , Fibrose , Gadolínio , Doenças das Valvas Cardíacas/veterinária , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/veterinária , Valva Mitral , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/veterinária , Troponina I
2.
Med Phys ; 46(8): 3520-3531, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31063248

RESUMO

PURPOSE: Accurate photon attenuation assessment from MR data remains an unmet challenge in the thorax due to tissue heterogeneity and the difficulty of MR lung imaging. As thoracic tissues encompass the whole physiologic range of photon absorption, large errors can occur when using, for example, a uniform, water-equivalent or a soft-tissue-only approximation. The purpose of this study was to introduce a method for voxel-wise thoracic synthetic CT (sCT) generation from MR data attenuation correction (AC) for PET/MR or for MR-only radiation treatment planning (RTP). METHODS: Acquisition: A radial stack-of-stars combining ultra-short-echo time (UTE) and modified Dixon (mDixon) sequence was optimized for thoracic imaging. The UTE-mDixon pulse sequence collects MR signals at three TE times denoted as UTE, Echo1, and Echo2. Three-point mDixon processing was used to reconstruct water and fat images. Bias field correction was applied in order to avoid artifacts caused by inhomogeneity of the MR magnetic field. ANALYSIS: Water fraction and R2* maps were estimated using the UTE-mDixon data to produce a total of seven MR features, that is UTE, Echo1, Echo2, Dixon water, Dixon fat, Water fraction, and R2*. A feature selection process was performed to determine the optimal feature combination for the proposed automatic, 6-tissue classification for sCT generation. Fuzzy c-means was used for the automatic classification which was followed by voxel-wise attenuation coefficient assignment as a weighted sum of those of the component tissues. Performance evaluation: MR data collected using the proposed pulse sequence were compared to those using a traditional two-point Dixon approach. Image quality measures, including image resolution and uniformity, were evaluated using an MR ACR phantom. Data collected from 25 normal volunteers were used to evaluate the accuracy of the proposed method compared to the template-based approach. Notably, the template approach is applicable here, that is normal volunteers, but may not be robust enough for patients with pathologies. RESULTS: The free breathing UTE-mDixon pulse sequence yielded images with quality comparable to those using the traditional breath holding mDixon sequence. Furthermore, by capturing the signal before T2* decay, the UTE-mDixon image provided lung and bone information which the mDixon image did not. The combination of Dixon water, Dixon fat, and the Water fraction was the most robust for tissue clustering and supported the classification of six tissues, that is, air, lung, fat, soft tissue, low-density bone, and dense bone, used to generate the sCT. The thoracic sCT had a mean absolute difference from the template-based (reference) CT of less than 50 HU and which was better agreement with the reference CT than the results produced using the traditional Dixon-based data. CONCLUSION: MR thoracic acquisition and analyses have been established to automatically provide six distinguishable tissue types to generate sCT for MR-based AC of PET/MR and for MR-only RTP.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Análise por Conglomerados , Humanos
3.
Invest Radiol ; 52(6): 334-342, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28059854

RESUMO

OBJECTIVE: The aim of this study was to demonstrate the feasibility of in vivo perforator visualization by a newly proposed magnetic resonance-based perforator phase contrast angiography (pPCA) technique for deep inferior epigastric perforator (DIEP) flap surgery and to prospectively compare its image quality and clinical value with computed tomographic angiography (CTA), the state-of-the-art perforator imaging technique. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. DIEP pPCA and CTA data were acquired in 10 female patients before DIEP flap surgery. Image findings were compared between the two techniques and with literature reports. RESULTS: The overall image quality is negatively correlated with patient BMI for CTA, but positively correlated with BMI for pPCA. Compared with CTA, pPCA has significantly better image quality (P = 0.005), signal-to-noise ratio (P < 0.001), and contrast-to-noise ratio (perforator-to-muscle, P < 0.001; perforator-to-fat, P = 0.014). It also has preferable clinical value ratings, although not statistically significant (P = 0.388). There is a good agreement (84%) between perforators detected by pPCA and CTA. Perforator location deviations between pPCA and CTA are compatible with the precision required for plastic surgery. Perforator size measured by pPCA seems to be more accurate than CTA, as it is 0.8 ± 0.3 mm smaller (P < 0.001), consistent with the reported 0.5 to 1.2 mm overestimation by CTA. There is no significant difference in perforator intramuscular course assessment (P = 0.415). CONCLUSIONS: The developed magnetic resonance-based pPCA technique presents superior image quality, better vessel contrast, and more accurate perforator anatomy than the x-ray-based CTA. pPCA has the potential to emerge as the preferred preoperative planning tool for perforator flap reconstructive surgery.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Artérias Epigástricas/transplante , Angiografia por Ressonância Magnética/métodos , Mamoplastia/métodos , Retalho Perfurante , Cuidados Pré-Operatórios/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
4.
J Magn Reson Imaging ; 43(1): 229-35, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26069205

RESUMO

BACKGROUND: To evaluate whether parallel radiofrequency transmission (mTX) can improve the symmetry of the left and right femoral arteries in dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of prostate and bladder cancer. METHODS: Eighteen prostate and 24 bladder cancer patients underwent 3.0 Tesla DCE-MRI scan with a single transmission channel coil. Subsequently, 21 prostate and 21 bladder cancer patients were scanned using the dual channel mTX upgrade. The precontrast signal ( S0) and the maximum enhancement ratio (MER) were measured in both the left and the right femoral arteries. Within the patient cohort, the ratio of S0 and MER in the left artery to that in the right artery ( S0_LR, MER_LR) was calculated with and without the use of mTX. Left to right asymmetry indices for S0 ( S0_LRasym) and MER ( MER_LRasym) were defined as the absolute values of the difference between S0_LR and 1, and the difference between MER_LR and 1, respectively. RESULTS: S0_LRasym, and MER_LRasym were 0.21 and 0.19 for prostate cancer patients with mTX, and 0.43 and 0.45 for the ones imaged without it (P < 0.001). Also, for the bladder cancer patients, S0_LRasym, and MER_LRasym were 0.11 and 0.9 with mTX, while imaging without it yielded 0.52 and 0.39 (P < 0.001). CONCLUSION: mTX can significantly improve left-to-right symmetry of femoral artery precontrast signal and contrast enhancement.


Assuntos
Artéria Femoral/metabolismo , Artéria Femoral/patologia , Gadolínio DTPA/farmacocinética , Angiografia por Ressonância Magnética/métodos , Neoplasias Pélvicas/irrigação sanguínea , Neoplasias Pélvicas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Simulação por Computador , Meios de Contraste/farmacocinética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Modelos Biológicos , Pelve/irrigação sanguínea , Pelve/patologia , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Magn Reson Imaging ; 33(4): 902-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21448956

RESUMO

PURPOSE: To describe a rapid T2*-weighted (T2*W), three-dimensional (3D) echo planar imaging (EPI) sequence and its application in mapping local magnetic susceptibility variations in 3 Tesla (T) prostate MRI. To compare the sensitivity of T2*W EPI with routinely used T1-weighted turbo-spin echo sequence (T1W TSE) in detecting hemorrhage and the implications on sequences sensitive to field inhomogeneities such as MR spectroscopy (MRS). MATERIALS AND METHODS: B(0) susceptibility weighted mapping was performed using a 3D EPI sequence featuring a 2D spatial excitation pulse with gradients of spiral k-space trajectory. A series of 11 subjects were imaged using 3T MRI and combination endorectal (ER) and six-channel phased array cardiac coils. T1W TSE and T2*W EPI sequences were analyzed quantitatively for hemorrhage contrast. Point resolved spectroscopy (PRESS MRS) was performed and data quality was analyzed. RESULTS: Two types of susceptibility variation were identified: hemorrhagic and nonhemorrhagic T2*W-positive areas. Post-biopsy hemorrhage lesions showed on average five times greater contrast on the T2*W images than T1W TSE images. Six nonhemorrhage regions of severe susceptibility artifact were apparent on the T2*W images that were not seen on standard T1W or T2W images. All nonhemorrhagic susceptibility artifact regions demonstrated compromised spectral quality on 3D MRS. CONCLUSION: The fast T2*W EPI sequence identifies hemorrhagic and nonhemorrhagic areas of susceptibility variation that may be helpful in prostate MRI planning at 3.0T.


Assuntos
Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Biópsia , Meios de Contraste/farmacologia , Hemorragia/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos
6.
Magn Reson Imaging Clin N Am ; 13(2): 241-54, v-vi, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15935310

RESUMO

This article reviews fundamental principles and sequence techniques that have been used successfully for imaging diseases of the abdomen and pelvis at 1.5 Tesla. This article also introduces concepts and the specific alteration of sequence parameters for optimization of abdominal-pelvic imaging at 3 Tesla.


Assuntos
Abdome/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Pelve/patologia , Meios de Contraste , Imagem Ecoplanar/métodos , Gadolínio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Magnetismo , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...