Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101294, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39131220

RESUMO

Background: Post-transcatheter aortic valve replacement (TAVR), paravalvular leak (PVL) is a quality metric associated with worse clinical outcomes. Transcatheter heart valve (THV) sizing is based primarily on the systolic annular size without regard to the left ventricular outflow tract (LVOT), which also lies within the THV landing zone. We hypothesized that LVOT size relative to the annulus is associated with post-TAVR PVL. Methods: Data from consecutive patients undergoing TAVR in a single high-volume center from January 2018 to March 2019 were used. Pre-TAVR data from multidetector computed tomography (MDCT) were collected. Relative LVOT area was defined as LVOT area/annular area during systole. Logistic regression analysis was used to evaluate association with post-TAVR mild or greater PVL by transthoracic echocardiography before discharge. Results: Among 293 patients (median age, 81.1 years; female, 49.5%; White, 88.0%), 81.6% received SAPIEN 3 and 18.4% received CoreValve THV models. Aortic valve morphology was bicuspid in 10.9% of patients. Prevalence of mild or greater PVL was 23.5% (mild in 20.1%). Relative LVOT area had a significant inverse association such that the odds of mild or greater PVL decreased significantly with every 1% increase in relative LVOT area (adjusted odds ratio, 0.96; 95% CI, 0.93-0.98; P = .002). There was no interaction between the type of implanted valve and the relative LVOT area. Patients in the highest relative LVOT tertile had significantly lower odds of mild or greater PVL (adjusted odds ratio, 0.42; 95% CI, 0.21-0.87; P = .018 vs first tertile). Conclusions: In patients undergoing TAVR with the newer generation of THV (SAPIEN 3 and CoreValve models), a relatively narrower LVOT area vs annular area was independently associated with increased odds of mild or greater PVL before discharge.

2.
J Soc Cardiovasc Angiogr Interv ; 3(6): 101359, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39132589

RESUMO

Background: There has been a significant increase in the utilization of venoarterial extracorporeal membrane oxygenation (VA-ECMO) in recent years. Cardiothoracic surgery teams have historically led VA-ECMO care teams, with little data available on alternative care models. Methods: We performed a retrospective review of a cardiovascular medicine inclusive VA-ECMO service, analyzing patients treated with peripheral VA-ECMO at a large quaternary care center from 2018 to 2022. The primary outcome was death while on VA-ECMO or within 24 hours of decannulation. Univariate and multivariate analyses were used to identify predictors of the primary outcome. Results: Two hundred forty-four patients were included in the analysis (median age 61 years; 28.7% female), of whom 91.8% were cannulated by interventional cardiologists, and 84.4% were managed by a cardiology service comprised of interventional cardiologists, cardiac intensivists or advanced heart failure cardiologists. Indications for VA-ECMO included acute myocardial infarction (34.8%), decompensated heart failure (30.3%), and refractory cardiac arrest (10.2%). VA-ECMO was utilized during cardiopulmonary resuscitation in 26.6% of cases, 48% of which were peri-procedural arrest. Of the patients, 46% survived to decannulation, the majority of whom were decannulated percutaneously in the cardiac catheterization laboratory. There was no difference in survival following cannulation by a cardiac surgeon vs interventional cardiologist (50% vs 45%; P = .90). Complications included arterial injury (3.7%), compartment syndrome (4.1%), cannulation site infection (1.2%), stroke (14.8%), acute kidney injury (52.5%), access site bleeding (16%) and need for blood transfusion (83.2%). Elevated baseline lactate (odds ratio [OR], 1.13 per unit increase) and sequential organ failure assessment score (OR, 1.27 per unit increase) were independently associated with the primary outcome. Conversely, an elevated baseline survival after VA ECMO score (OR, 0.92 per unit increase) and 8-hour serum lactate clearance (OR, 0.98 per % increase) were independently associated with survival. Conclusions: The use of a cardiovascular medicine inclusive ECMO service is feasible and may be practical in select centers as indications for VA-ECMO expand.

4.
Curr Probl Cardiol ; 49(8): 102646, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38820919

RESUMO

Up to 20 % of patients presenting with acute heart failure and cardiogenic shock have a structural etiology. Despite efforts in timely management, mortality rates remain alarmingly high, ranging from 50 % to 80 %. Surgical intervention is often the definitive treatment for structural heart disease; however, many patients are considered high risk or unsuitable candidates for such procedures. Consequently, there has been a paradigm shift towards the development of novel percutaneous management strategies and temporizing interventions. This article aims to provide a comprehensive review of the pathophysiology of valvular and structural heart conditions presenting in cardiogenic shock, focusing on the evolving landscape of mechanical circulatory support devices and other management modalities.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Assistência Perioperatória/métodos , Cardiopatias , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia
5.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639143

RESUMO

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Assuntos
Técnicas de Ablação , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica , Etanol , Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos , Masculino , Etanol/administração & dosagem , Etanol/efeitos adversos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-38670866

RESUMO

BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.

7.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38660790

RESUMO

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Assuntos
American Heart Association , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Estados Unidos , Doenças das Valvas Cardíacas/terapia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia , Implante de Prótese de Valva Cardíaca
11.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38212236

RESUMO

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Masculino , Feminino , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/terapia , Cateterismo Cardíaco/efeitos adversos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Adulto
13.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37842844

RESUMO

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Imagem Multimodal , Resultado do Tratamento
14.
Echocardiography ; 40(8): 884-887, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37319117

RESUMO

Pacer wire induced tricuspid regurgitation is not well-understood. The mechanisms behind pacer wired induced tricuspid regurgitation have not been clearly defined. This clinical vignette sets to identify different technical mechanisms behind cardiac lead induced tricuspid regurgitation to help optimize cardiac lead implantation strategies for future device implantation.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Ecocardiografia Tridimensional , Tomografia Computadorizada por Raios X
15.
JACC Cardiovasc Interv ; 16(16): 1953-1960, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37212431

RESUMO

BACKGROUND: Transcatheter treatment of patients with native aortic valve regurgitation (AR) has been limited by anatomical factors. No transcatheter device has received U.S. regulatory approval for the treatment of patients with AR. OBJECTIVES: The aim of this study was to describe the compassionate-use experience in North America with a dedicated transcatheter device (J-Valve). METHODS: A multicenter, observational registry was assembled of compassionate-use cases of J-Valve implantation for the treatment of patients with severe symptomatic AR and elevated surgical risk in North America. The J-Valve consists of a self-expanding Nitinol frame, bovine pericardial leaflets, and a valve-locating feature. The available size matrix (5 sizes) can treat a wide range of anatomies (minimum and maximum annular perimeters 57-104 mm). RESULTS: A total of 27 patients (median age 81 years [IQR: 72-85 years], 81% at high surgical risk, 96% in NYHA functional class III or IV) with native valve AR were treated with the J-Valve during the study period (2018-2022). Procedural success (J-Valve delivered to the intended location without the need for surgical conversion or a second transcatheter heart valve) was 81% (22 of 27 cases) in the overall experience and 100% in the last 15 cases. Two cases required conversion to surgery in the early experience, leading to changes in valve design. At 30 days, there was 1 death, 1 stroke, and 3 new pacemakers (13%), and 88% of patients were in NYHA functional class I or II. No patient had residual AR of moderate or greater degree at 30 days. CONCLUSIONS: The J-Valve appears to provide a safe and effective alternative to surgery in patients with pure AR and elevated or prohibitive surgical risk.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Animais , Bovinos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
17.
Cardiovasc Revasc Med ; 53: 1-7, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37012106

RESUMO

BACKGROUND/PURPOSE: Percutaneous valve interventions for aortic stenosis (AS) include transcatheter aortic valve replacement (TAVR) and balloon aortic valvuloplasty (BAV). Intraprocedural mechanical circulatory support (MCS) with Impella devices (Abiomed, Danvers, MA) is used in select high-risk patients, although data regarding its efficacy is limited. This study sought to evaluate the clinical outcomes of Impella use in patients with AS who underwent TAVR and BAV at a quaternary-care center. METHODS/MATERIALS: All patients with severe AS who underwent TAVR and BAV with Impella between 2013 and 2020 were included. Patient demographics, outcomes, complications, and 30-day mortality data was analyzed. RESULTS: Over the study period 2680 procedures were performed, 1965 TAVR and 715 BAV. 120 utilized Impella support, 26 TAVR and 94 BAV. Among TAVR Impella cases, justifications for MCS included cardiogenic shock (53.9 %), cardiac arrest (19.2 %), and coronary occlusion (15.4 %). Among BAV Impella cases, justifications for MCS included cardiogenic shock (55.3 %) and protected percutaneous coronary intervention (43.6 %). The 30-day mortality rate in TAVR Impella was 34.6 % and in BAV Impella was 28 %. BAV Impella cases involving cardiogenic shock had a higher rate of 45 %. Impella remained in-use past 24 h from the procedure in 32.2 % cases. Vascular access-related complications occurred in 4.8 % cases and bleeding complications occurred in 1.5 % cases. Conversion to open-heart surgery occurred in 0.7 % cases. CONCLUSIONS: MCS is an option for high-risk patients with severe AS who require TAVR and BAV. Despite hemodynamic support, the 30-day mortality rate remained high especially in cases where support was employed for cardiogenic shock.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Choque Cardiogênico/complicações , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Hemodinâmica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
18.
Catheter Cardiovasc Interv ; 101(1): 164-169, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378598

RESUMO

Aspiration thrombectomy with the AngioVac is approved for percutaneous removal of thrombus in the venous system. While not approved for aspiration of thrombus or other mass in the left heart or arterial system, it has been used in that setting. Patients with left heart or arterial mass are often deemed unfavorable for surgery and treated conservatively. This may not be the best option for all patients, as some may have lesions that represent a short-term increased risk of complications, for which intervention and aspiration could be considered reasonable. Unfortunately, femoral arteries sizes often cannot accommodate the Angiovac current aspiration cannula dimensions. Here, we demonstrated trans-caval approach for aspiration thrombectomy of extensive aortic mobile plaque and thrombus.


Assuntos
Placa Aterosclerótica , Trombose , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Trombectomia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA