Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 94, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326736

RESUMO

BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) and atrial fibrillation (AF) frequently co-exist. There is a limited understanding on whether this coexistence is associated with distinct alterations in myocardial remodelling and mechanics. We aimed to determine if patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) represent a distinct phenotype. METHODS: In this secondary analysis of adults with HFpEF (NCT03050593), participants were comprehensively phenotyped with stress cardiac MRI, echocardiography and plasma fibroinflammatory biomarkers, and were followed for the composite endpoint (HF hospitalisation or death) at a median of 8.5 years. Those with AF were compared to sinus rhythm (SR) and unsupervised cluster analysis was performed to explore possible phenotypes. RESULTS: 136 subjects were included (SR = 75, AF = 61). The AF group was older (76 ± 8 vs. 70 ± 10 years) with less diabetes (36% vs. 61%) compared to the SR group and had higher left atrial (LA) volumes (61 ± 30 vs. 39 ± 15 mL/m2, p < 0.001), lower LA ejection fraction (EF) (31 ± 15 vs. 51 ± 12%, p < 0.001), worse left ventricular (LV) systolic function (LVEF 63 ± 8 vs. 68 ± 8%, p = 0.002; global longitudinal strain 13.6 ± 2.9 vs. 14.7 ± 2.4%, p = 0.003) but higher LV peak early diastolic strain rates (0.73 ± 0.28 vs. 0.53 ± 0.17 1/s, p < 0.001). The AF group had higher levels of syndecan-1, matrix metalloproteinase-2, proBNP, angiopoietin-2 and pentraxin-3, but lower level of interleukin-8. No difference in clinical outcomes was observed between the groups. Three distinct clusters were identified with the poorest outcomes (Log-rank p = 0.029) in cluster 2 (hypertensive and fibroinflammatory) which had equal representation of SR and AF. CONCLUSIONS: Presence of AF in HFpEF is associated with cardiac structural and functional changes together with altered expression of several fibro-inflammatory biomarkers. Distinct phenotypes exist in HFpEF which may have differing clinical outcomes.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Adulto , Volume Sistólico , Metaloproteinase 2 da Matriz , Função Ventricular Esquerda , Biomarcadores , Fenótipo , Prognóstico
2.
J Thorac Oncol ; 18(5): 587-598, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36646209

RESUMO

INTRODUCTION: We aimed to define a baseline radiomic signature associated with overall survival (OS) using baseline computed tomography (CT) images obtained from patients with NSCLC treated with nivolumab or chemotherapy. METHODS: The radiomic signature was developed in patients with NSCLC treated with nivolumab in CheckMate-017, -026, and -063. Nivolumab-treated patients were pooled and randomized to training, calibration, or validation sets using a 2:1:1 ratio. From baseline CT images, volume of tumor lesions was semiautomatically segmented, and 38 radiomic variables depicting tumor phenotype were extracted. Association between the radiomic signature and OS was assessed in the nivolumab-treated (validation set) and chemotherapy-treated (test set) patients in these studies. RESULTS: A baseline radiomic signature was identified using CT images obtained from 758 patients. The radiomic signature used a combination of imaging variables (spatial correlation, tumor volume in the liver, and tumor volume in the mediastinal lymph nodes) to output a continuous value, ranging from 0 to 1 (from most to least favorable estimated OS). Given a threshold of 0.55, the sensitivity and specificity of the radiomic signature for predicting 3-month OS were 86% and 77.8%, respectively. The signature was identified in the training set of patients treated with nivolumab and was significantly associated (p < 0.0001) with OS in patients treated with nivolumab or chemotherapy. CONCLUSIONS: The radiomic signature provides an early readout of the anticipated OS in patients with NSCLC treated with nivolumab or chemotherapy. This could provide important prognostic information and may support risk stratification in clinical trials.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Nivolumabe/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Prognóstico , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos
3.
J Magn Reson Imaging ; 56(3): 712-724, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35092323

RESUMO

BACKGROUND: Treatments for nonalcoholic steatohepatitis (NASH) are urgently needed. Hepatic fat fraction and shear stiffness quantified by magnetic resonance imaging (MRI-HFF) and magnetic resonance elastography (MRE-SS), respectively, are biomarkers for hepatic steatosis and fibrosis. PURPOSE: This study assessed the longitudinal effects of fibroblast growth factor 21 variant (polyethylene glycol [PEG]-FGF21v) on MRI-HFF and MRE-SS in a NASH mouse model. STUDY TYPE: Preclinical. ANIMAL MODEL: This study included a choline-deficient, amino acid-defined, high-fat diet (CDAHFD) model and 6-week-old, male C57BL/6J mice (N = 78). FIELD STRENGTH/SEQUENCE: This study was performed using: 3T: gradient-echo two-point Dixon and spin-echo (SE) echo-planar imaging elastography (200 Hz) and 7T: SE two-point Dixon and SE elastography (200 Hz). ASSESSMENT: MRI and MRE were performed before control diet (CD) or CDAHFD (BD), before PEG-FGF21v dosing (baseline), and after PEG-FGF21v treatment (WK4/8). Regions of interest for MRI-HFF and MRE-SS were delineated by J.L. and H.T. (>5 years of experience each). Fibrosis and steatosis were measured histologically after picrosirius red and H&E staining. Alkaline phosphatase, alanine transaminase, bile acids, and triglycerides (TGs) were measured. STATISTICAL TESTS: Two-tailed Dunnett's tests were used for statistical analysis; untreated CDAHFD or baseline was used for comparisons. Imaging and histology/biochemistry data were determined using Spearman correlations. Bayesian posterior distributions for MRE-SS at WK8, posterior means, and 95% credible intervals were presented. RESULTS: CDAHFD significantly increased baseline MRI-HFF (3T: 21.97% ± 0.29%; 7T: 40.12% ± 0.35%) and MRE-SS (3T: 1.25 ± 0.02; 7T: 1.78 ± 0.06 kPa) vs. CD (3T: 3.45% ± 0.7%; 7T: 12.06% ± 1.4% and 3T: 1.01 ± 0.02; 7T: 0.89 ± 0.06 kPa). At 7T, PEG-FGF21v significantly decreased MRI-HFF (WK4: 28.97% ± 1.22%; WK8: 20.93% ± 1.15%) and MRE-SS (WK4: 1.57 ± 0.04; WK8: 1.36 ± 0.05 kPa) vs. untreated (WK4: 36.36% ± 0.62%; WK8: 30.58% ± 0.81% and WK4: 2.03 ± 0.06; WK8: 2.01 ± 0.04 kPa); 3T trends were similar. WK8 SS posterior mean percent attenuation ratios (RDI ) were -68% (-90%, -44%; 3T) and -64% (-78%, -52%; 7T). MRI-HFF was significantly correlated with H&E (3T, r = 0.93; 7T, r = 0.94) and TGs (both, r = 0.92). DATA CONCLUSIONS: MRI-HFF and MRE-SS showed PEG-FGF21v effects on hepatic steatosis and fibrosis across 3 and 7T, consistent with histological and biochemical data. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Animais , Teorema de Bayes , Modelos Animais de Doenças , Técnicas de Imagem por Elasticidade/métodos , Fatores de Crescimento de Fibroblastos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Polietilenoglicóis
4.
JACC Cardiovasc Imaging ; 14(1): 203-215, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32950445

RESUMO

OBJECTIVES: The purpose of this study was to determine the relationship between body composition, N-terminal B-type natriuretic peptide (NT-proBNP) levels, and heart failure (HF) phenotypes and outcomes. BACKGROUND: Abnormalities in body composition can influence metabolic dysfunction and HF severity; however, data assessing fat distribution and skeletal muscle (SM) size in HF with reduced (HFrEF) and preserved EF (HFpEF) are limited. Further, whether NPs relate more closely to axial muscle mass than measures of adiposity is not well studied. METHODS: We studied 572 adults without HF (n = 367), with HFrEF (n = 113), or with HFpEF (n = 92). Cardiac magnetic resonance was used to assess subcutaneous and visceral abdominal fat, paracardial fat, and axial SM size. We measured NT-proBNP in 334 participants. We used Cox regression to analyze the relationship between body composition and mortality. RESULTS: Compared with controls, pericardial and subcutaneous fat thickness were significantly increased in HFpEF, whereas patients with HFrEF had reduced axial SM size after adjusting for age, sex, race, and body height (p < 0.05 for comparisons). Lower axial SM size, but not fat, was significantly predictive of death in unadjusted (standardized hazard ratio: 0.63; p < 0.0001) and multivariable-adjusted analyses (standardized hazard ratio = 0.72; p = 0.0007). NT-proBNP levels more closely related to lower axial SM rather than fat distribution or body mass index (BMI) in network analysis, and when simultaneously assessed, only SM (p = 0.0002) but not BMI (p = 0.18) was associated with NT-proBNP. However, both NT-proBNP and axial SM mass were independently predictive of death (p < 0.05). CONCLUSIONS: HFpEF and HFrEF have distinct abnormalities in body composition. Reduced axial SM, but not fat, independently predicts mortality. Greater axial SM more closely associates with lower NT-proBNP rather than adiposity. Lower NT-proBNP levels in HFpEF compared with HFrEF relate more closely to muscle mass rather than obesity.


Assuntos
Insuficiência Cardíaca , Idoso , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Biomarcadores , Composição Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda
5.
Clin Cancer Res ; 26(9): 2151-2162, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32198149

RESUMO

PURPOSE: Using standard-of-care CT images obtained from patients with a diagnosis of non-small cell lung cancer (NSCLC), we defined radiomics signatures predicting the sensitivity of tumors to nivolumab, docetaxel, and gefitinib. EXPERIMENTAL DESIGN: Data were collected prospectively and analyzed retrospectively across multicenter clinical trials [nivolumab, n = 92, CheckMate017 (NCT01642004), CheckMate063 (NCT01721759); docetaxel, n = 50, CheckMate017; gefitinib, n = 46, (NCT00588445)]. Patients were randomized to training or validation cohorts using either a 4:1 ratio (nivolumab: 72T:20V) or a 2:1 ratio (docetaxel: 32T:18V; gefitinib: 31T:15V) to ensure an adequate sample size in the validation set. Radiomics signatures were derived from quantitative analysis of early tumor changes from baseline to first on-treatment assessment. For each patient, 1,160 radiomics features were extracted from the largest measurable lung lesion. Tumors were classified as treatment sensitive or insensitive; reference standard was median progression-free survival (NCT01642004, NCT01721759) or surgery (NCT00588445). Machine learning was implemented to select up to four features to develop a radiomics signature in the training datasets and applied to each patient in the validation datasets to classify treatment sensitivity. RESULTS: The radiomics signatures predicted treatment sensitivity in the validation dataset of each study group with AUC (95 confidence interval): nivolumab, 0.77 (0.55-1.00); docetaxel, 0.67 (0.37-0.96); and gefitinib, 0.82 (0.53-0.97). Using serial radiographic measurements, the magnitude of exponential increase in signature features deciphering tumor volume, invasion of tumor boundaries, or tumor spatial heterogeneity was associated with shorter overall survival. CONCLUSIONS: Radiomics signatures predicted tumor sensitivity to treatment in patients with NSCLC, offering an approach that could enhance clinical decision-making to continue systemic therapies and forecast overall survival.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Aprendizado de Máquina , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/patologia , Ensaios Clínicos Fase II como Assunto , Ensaios Clínicos Fase III como Assunto , Progressão da Doença , Docetaxel/administração & dosagem , Feminino , Gefitinibe/administração & dosagem , Humanos , Neoplasias Pulmonares/patologia , Masculino , Nivolumabe/administração & dosagem , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Taxa de Sobrevida
6.
J Psychopharmacol ; 32(2): 146-155, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29378483

RESUMO

Major depressive disorder is a leading cause of disability globally. Improvements in the efficacy of antidepressant therapy are needed as a high proportion (>40%) of individuals with major depressive disorder fail to respond adequately to current treatments. The non-selective N-methyl-D-aspartate receptor channel blocker, (±)-ketamine, has been reported to produce a rapid and long-lasting antidepressant response in treatment-resistant major depressive disorder patients, which provides a unique opportunity for investigation of mechanisms that mediate its therapeutic effect. Efforts have also focused on the development of selective N-methyl-D-aspartate receptor subtype 2B antagonists which may retain antidepressant activity but have lower potential for dissociative/psychotomimetic effects. In the present study, we examined the central nervous system effects of acute, intravenous administration of (±)-ketamine or the N-methyl-D-aspartate receptor subtype 2B antagonist, traxoprodil, in awake rats using pharmacological magnetic resonance imaging. The study contained five treatment groups: vehicle, 3 mg/kg (±)-ketamine, and three doses of traxoprodil (0.3 mg/kg, 5 mg/kg, and 15 mg/kg). Non-linear model fitting was performed on the temporal hemodynamic pharmacological magnetic resonance imaging data to generate brain activation maps as well as regional responses based on blood oxygen level dependent signal changes for group analysis. Traxoprodil at 5 mg/kg and 15 mg/kg produced a dose-dependent pharmacological magnetic resonance imaging signal in rat forebrain regions with both doses achieving >80% N-methyl-D-aspartate receptor subtype 2B occupancy determined by ex vivo [3H]Ro 25-6981 binding. The middle dose of traxoprodil (5 mg/kg) generated region-specific activations in medial prefrontal cortex, ventral orbital cortex, and anterior cingulate cortex whereas the high dose (15 mg/kg) produced a widespread pharmacological magnetic resonance imaging response in both cortical and subcortical brain regions which was similar to that produced by (±)-ketamine (3 mg/kg, intravenous).


Assuntos
Transtorno Depressivo Maior/tratamento farmacológico , Ketamina/farmacologia , Imageamento por Ressonância Magnética/métodos , Piperidinas/farmacologia , Animais , Antidepressivos/administração & dosagem , Antidepressivos/farmacologia , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Transtorno Depressivo Maior/fisiopatologia , Relação Dose-Resposta a Droga , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Antagonistas de Aminoácidos Excitatórios/farmacologia , Ketamina/administração & dosagem , Masculino , Dinâmica não Linear , Fenóis/farmacologia , Piperidinas/administração & dosagem , Ratos , Ratos Sprague-Dawley , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Vigília
7.
J Biomed Opt ; 15(2): 021305, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20459227

RESUMO

We present our findings from a real-time laser optoacoustic imaging system (LOIS). The system utilizes a Q-switched Nd:YAG laser; a standard 128-channel ultrasonic linear array probe; custom electronics and custom software to collect, process, and display optoacoustic (OA) images at 10 Hz. We propose that this system be used during preoperative mapping of forearm vessels for hemodialysis treatment. To demonstrate the real-time imaging capabilities of the system, we show OA images of forearm vessels in a volunteer and compare our results to ultrasound images of the same region. Our OA images show blood vessels in high contrast. Manipulations with the probe enable us to locate and track arteries and veins of a forearm in real time. We also demonstrate the ability to combine a series of OA image slices into a volume for spatial representation of the vascular network. Finally, we use frame-by-frame analysis of the recorded OA video to measure dynamic changes of the crossection of the ulnar artery.


Assuntos
Braço/fisiopatologia , Artérias/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Imageamento Tridimensional/instrumentação , Fluxometria por Laser-Doppler/instrumentação , Transdutores , Braço/irrigação sanguínea , Velocidade do Fluxo Sanguíneo/fisiologia , Sistemas Computacionais , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Biomed Opt ; 15(2): 021310, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20459232

RESUMO

Optoacoustic (OA) tomography has demonstrated utility in identifying blood-rich malignancies in breast tissue. We describe the development and characterization of a laser OA imaging system for the prostate (LOIS-P). The system consists of a fiber-coupled Q-switched laser operating at 757 nm, a commercial 128-channel ultrasonic probe, a digital signal processor, and software that uses the filtered radial back-projection algorithm for image reconstruction. The system is used to reconstruct OA images of a blood-rich lesion induced in vivo in a canine prostate. OA images obtained in vivo are compared to images acquired using ultrasound, the current gold standard for guiding biopsy of the prostate. Although key structural features such as the urethra could be identified with both imaging techniques, a bloody lesion representing a highly vascularized tumor could only be clearly identified in OA images. The advantages and limitations of both forward and backward illumination modes are also evaluated by collecting OA images of phantoms simulating blood vessels within tissue. System resolution is estimated to be 0.2 mm in the radial direction of the acoustic array. The minimum detectable pressure signal is 1.83 Pa. Our results encourage further development toward a dual-modality OA/ultrasonic system for prostate imaging and image-guided biopsy.


Assuntos
Biópsia por Agulha/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Lasers , Próstata/diagnóstico por imagem , Próstata/patologia , Cirurgia Assistida por Computador/métodos , Transdutores , Animais , Desenho Assistido por Computador , Cães , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Rev Sci Instrum ; 80(9): 093708, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19791945

RESUMO

Comprehensive characterization of wideband ultrasonic transducers and specifically optoacoustic detectors is achieved through the analysis of their frequency response as a function of the incident angle. The tests are performed under well-defined, repeatable operating conditions. Backillumination of a blackened, acoustically matched planar surface with a short laser pulse creates an acoustic impulse which is used as a wideband ultrasonic source. Upon illumination with a short laser pulse, the bandwidth of our source shows a -6 dB point of 12 MHz and a low-frequency roll-off around 300 kHz. Using proprietary software, we examine thoroughly the planarity of the emitted wave front within a specified amplitude cutoff and phase incoherence. Analysis of the angular dependence of the frequency response yields invaluable directivity information about the detector under study: a necessary component toward accurate optoacoustic image reconstruction and quantitative tomography. The laser ultrasonic source we developed is the main feature of our directivity measurement setup. Due to its simplicity, it can easily be adapted to various calibration devices. This paper focuses on the development and characterization of the flatness and the bandwidth of our wideband ultrasonic source.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Lasers , Iluminação/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Ultrassom
10.
Ultrasound Med Biol ; 35(2): 329-38, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18947918

RESUMO

We describe early stage experiments to test the feasibility of an ultrasound brain helmet to produce multiple simultaneous real-time three-dimensional (3D) scans of the cerebral vasculature from temporal and suboccipital acoustic windows of the skull. The transducer hardware and software of the Volumetrics Medical Imaging (Durham, NC, USA) real-time 3D scanner were modified to support dual 2.5 MHz matrix arrays of 256 transmit elements and 128 receive elements which produce two simultaneous 64 degrees pyramidal scans. The real-time display format consists of two coronal B-mode images merged into a 128 degrees sector, two simultaneous parasagittal images merged into a 128 degrees x 64 degrees C-mode plane and a simultaneous 64 degrees axial image. Real-time 3D color Doppler scans from a skull phantom with latex blood vessel were obtained after contrast agent injection as a proof of concept. The long-term goal is to produce real-time 3D ultrasound images of the cerebral vasculature from a portable unit capable of internet transmission thus enabling interactive 3D imaging, remote diagnosis and earlier therapeutic intervention. We are motivated by the urgency for rapid diagnosis of stroke due to the short time window of effective therapeutic intervention.


Assuntos
Circulação Cerebrovascular , Ecoencefalografia/instrumentação , Ecoencefalografia/métodos , Imageamento Tridimensional , Ultrassonografia Doppler em Cores/instrumentação , Ultrassonografia Doppler em Cores/métodos , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Transdutores
11.
J Biomed Opt ; 14(6): 064007, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20059245

RESUMO

We develop a system for three-dimensional whole-body optoacoustic tomography of small animals for applications in preclinical research. The tomographic images are obtained while the objects of study (phantoms or mice) are rotated within a sphere outlined by a concave arc-shaped array of 64 piezocomposite transducers. Two pulsed lasers operating in the near-IR spectral range (755 and 1064 nm) with an average pulsed energy of about 100 mJ, a repetition rate of 10 Hz, and a pulse duration of 15 to 75 ns are used as optical illumination sources. During the scan, the mouse is illuminated orthogonally to the array with two wide beams of light from a bifurcated fiber bundle. The system is capable of generating images of individual organs and blood vessels through the entire body of a mouse with spatial resolution of approximately 0.5 mm.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Tomografia Óptica/métodos , Imagem Corporal Total/métodos , Animais , Vasos Sanguíneos/anatomia & histologia , Cabelo , Cavalos , Imageamento Tridimensional/métodos , Camundongos , Imagens de Fantasmas
12.
Artigo em Inglês | MEDLINE | ID: mdl-18599423

RESUMO

Ultrasound image guidance of interventional devices during minimally invasive surgery provides the clinician with improved soft tissue contrast while reducing ionizing radiation exposure. One problem with ultrasound image guidance is poor visualization of the device tip during the clinical procedure. We have described previously guidance of several interventional devices using a real-time 3-D (RT3-D) ultrasound system with 3-D color Doppler combined with the ColorMark technology. We then developed an analytical model for a vibrating needle to maximize the tip vibrations and improve the reliability and sensitivity of our technique. In this paper, we use the analytical model and improved radiofrequency (RF) and color Doppler filters to detect two different vibrating devices in water tank experiments as well as in an in vivo canine experiment. We performed water tank experiments with four different 3- D transducers: a 5 MHz transesophageal (TEE) probe, a 5 MHz transthoracic (TTE) probe, a 5 MHz intracardiac catheter (ICE) transducer, and a 2.5 MHz commercial TTE probe. Each transducer was used to scan an aortic graft suspended in the water tank. An atrial septal puncture needle and an endomyocardial biopsy forceps, each vibrating at 1.3 kHz, were inserted into the vascular graft and were tracked using 3-D color Doppler. Improved RF and wall filters increased the detected color Doppler sensitivity by 14 dB. In three simultaneous planes from the in vivo 3-D scan, we identified both the septal puncture needle and the biopsy forceps within the right atrium using the 2.5 MHz probe. A new display filter was used to suppress the unwanted flash artifact associated with physiological motion.


Assuntos
Ecocardiografia Doppler em Cores/instrumentação , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Transdutores , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Vibração
13.
Anesth Analg ; 105(6): 1858-60, table of contents, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18042895

RESUMO

Ultrasound imaging has been used for performing single-injection peripheral nerve blocks and continuous catheters. One limitation with current technology is the inability to confirm the location of the needle or catheter tip. We describe a new needle and catheter design that permits distal tip visualization using color flow Doppler. An 18-gauge 100-mm insulated Tuohy needle and a 20-gauge 50-mm polyamide catheter (open tip) with a Teflon-coated steel stylet (B. Braun, Bethlehem, PA) were customized by adhering in place two piezoelectric actuators. These created 1-8 kHz vibrations when coupled to a function generator (FG502, Tektronix, Richardson, TX) and a 100 W audio amplifier (R3000, KLH, Sun Valley, CA). Mimicking a lateral popliteal fossa block, the needle and catheter were inserted into the leg of an unembalmed cadaver. When activated, the tip of each was highlighted in color when scanned in the short axis using the color Doppler mode of a two-dimensional ultrasound and a 12 MHz L38 probe (MicroMaxx, Sonosite, Bothell, WA). Vibration technology may be a useful adjunct while performing ultrasound-guided regional anesthesia. Further study evaluating its usefulness and safety in live tissue is warranted.


Assuntos
Bloqueio Nervoso Autônomo/instrumentação , Terapia por Estimulação Elétrica/instrumentação , Agulhas , Nervos Periféricos/diagnóstico por imagem , Idoso , Bloqueio Nervoso Autônomo/métodos , Cateterismo , Terapia por Estimulação Elétrica/métodos , Humanos , Masculino , Ultrassonografia , Vibração/uso terapêutico
14.
Artigo em Inglês | MEDLINE | ID: mdl-17703675

RESUMO

Ultrasound guidance of interventional devices during minimally invasive surgical procedures has been investigated by many researchers. Previously, we extended the methods used by the Colormark tracking system to several interventional devices using a real-time, three-dimensional (3-D) ultrasound system. These results showed that we needed to improve the efficiency and reliability of the tracking. In this paper, we describe an analytical model to predict the transverse vibrations along the length of an atrial septal puncture needle to enable design improvements of the tracking system. We assume the needle can be modeled as a hollow bar with a circular cross section with a fixed proximal end and a free distal end that is suspended vertically to ignore gravity effects. The initial results show an ability to predict the natural nodes and antinodes along the needle using the characteristic equation for free vibrations. Simulations show that applying a forcing function to the device at a natural antinode yields an order of magnitude larger vibration than when driving the device at a node. Pulsed wave spectral Doppler data was acquired along the distal portion of the needle in a water tank using a 2-D matrix array transesophageal echocardiography probe. This data was compared to simulations of forced vibrations from the model. These initial results suggest that the model is a good first order approximation of the vibrating device in a water tank. It is our belief that knowing the location of the natural nodes and antinodes will improve our ability to drive the device to ensure the vibrations at the proximal end will reach the tip of the device, which in turn should improve our ability to track the device in vivo.


Assuntos
Imageamento Tridimensional , Procedimentos Cirúrgicos Minimamente Invasivos , Agulhas , Ultrassonografia Doppler em Cores/instrumentação , Ultrassonografia de Intervenção/instrumentação , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Vibração
15.
Ultrason Imaging ; 29(4): 213-9, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18481593

RESUMO

The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.


Assuntos
Biópsia por Agulha/instrumentação , Imageamento Tridimensional/instrumentação , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Algoritmos , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
16.
IEEE Trans Ultrason Ferroelectr Freq Control ; 53(11): 1999-2008, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17091836

RESUMO

Laparoscopic ultrasound has seen increased use as a surgical aide in general, gynecological, and urological procedures. The application of real-time, three-dimensional (RT3D) ultrasound to these laparoscopic procedures may increase information available to the surgeon and serve as an additional intraoperative guidance tool. The integration of RT3D with recent advances in robotic surgery also can increase automation and ease of use. In this study, a 1-cm diameter probe for RT3D has been used laparoscopically for in vivo imaging of a canine. The probe, which operates at 5 MHz, was used to image the spleen, liver, and gall bladder as well as to guide surgical instruments. Furthermore, the three-dimensional (3-D) measurement system of the volumetric scanner used with this probe was tested as a guidance mechanism for a robotic linear motion system in order to simulate the feasibility of RT3D/robotic surgery integration. Using images acquired with the 3-D laparoscopic ultrasound device, coordinates were acquired by the scanner and used to direct a robotically controlled needle toward desired in vitro targets as well as targets in a post-mortem canine. The rms error for these measurements was 1.34 mm using optical alignment and 0.76 mm using ultrasound alignment.


Assuntos
Imageamento Tridimensional/instrumentação , Laparoscópios , Robótica/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Animais , Cães , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Imageamento Tridimensional/métodos , Laparoscopia/métodos , Robótica/métodos , Integração de Sistemas , Ultrassonografia de Intervenção/métodos
17.
Artigo em Inglês | MEDLINE | ID: mdl-16471436

RESUMO

Modifications were made to a commercial real-time, three-dimensional (3-D) ultrasound system for near simultaneous 3-D scanning with two matrix array transducers. As a first illustration, a transducer cable assembly was modified to incorporate two independent, 3-D intra-cardiac echo catheters, a 7 Fr (2.3 mm O.D.) side scanning catheter and a 14 Fr (4.7 mm O.D) forward viewing catheter with accessory port, each catheter using 85 channels operating at 5 MHz. For applications in treatment of atrial fibrillation, the goal is to place the sideviewing catheter within the coronary sinus to view the whole left atrium, including a pulmonary vein. Meanwhile, the forward-viewing catheter inserted within the left atrium is directed toward the ostium of a pulmonary vein for therapy using the integrated accessory port. Using preloaded, phasing data, the scanner switches between catheters automatically, at the push of a button, with a delay of about 1 second, so that the clinician can view the therapy catheter with the coronary sinus catheter and vice versa. Preliminary imaging studies in a tissue phantom and in vivo show that our system successfully guided the forward-viewing catheter toward a target while being imaged with the sideviewing catheter. The forward-viewing catheter then was activated to monitor the target while we mimicked therapy delivery. In the future, the system will switch between 3-D probes on a line-by-line basis and display both volumes simultaneously.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Transdutores , Animais , Sistemas Computacionais , Cães , Ecocardiografia Tridimensional/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Ultrason Imaging ; 28(4): 245-54, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17521045

RESUMO

Real-time 3D ultrasound was developed at Duke University in 1991 and has since been used with a variety of transducers and shown effectiveness in clinical applications and in vivo animal imaging studies. Methods for displaying the 3D pyramid of data acquired by the system include selecting 2D image slices or integrating data into a volume rendered view. A third method, real-time stereo 3D imaging, is discussed here. The clinical commercial 3D system has been modified in our laboratory to display a real-time stereo image pair on the scanner display to be viewed through a stereoscope. This merges the pair into a single image, with a sensation of depth. Stereoscopic displays have previously been demonstrated to provide benefits, including improved depth judgments and increased perception of image quality in other applications. Previously-saved volumes of ultrasound data are shown in stereo 3D using the new system.


Assuntos
Imageamento Tridimensional , Ultrassonografia/métodos , Animais , Cães , Endossonografia/métodos , Esôfago/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Matemática , Valva Mitral/diagnóstico por imagem , Ovinos , Transdutores
19.
Ultrason Imaging ; 26(3): 173-84, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15754798

RESUMO

The goal of this investigation was to examine the feasibility of guiding interventional devices using piezoelectric buzzers to create velocity sources, which were imaged and tracked with real-time 3D color flow Doppler. The interventional devices examined in this study included a pacemaker lead, Brockenbrough needle for cardiac septal puncture, cardiac guidewire and radiofrequency ablation needles for cancer therapy. Each was mechanically coupled to a piezoelectric buzzer and was imaged using a commercial real-time 3D ultrasound system with either a 2.5 MHz matrix array transducer or a 5 MHz, 22 F catheter transducer equipped with a tool port. In vitro images acquired in tissue phantoms, excised liver with a 'tumor' target and an excised sheep heart show strong vibration signals in 3D color flow Doppler, enabling real-time tracking and guidance of all the devices in three dimensions. In a sheep model, in vivo tracking of the pacing lead was performed in the superior vena cava as well as the right atrium using RT3D color flow Doppler images. The vibrating rf ablation needles were guided through the liver toward "tumor" targets in vivo with real-time 3D color flow Doppler images.


Assuntos
Ablação por Cateter/instrumentação , Marca-Passo Artificial , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia de Intervenção , Animais , Eletrodos Implantados , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Ovinos , Ultrassonografia Doppler em Cores/instrumentação , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...