Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35808424

RESUMO

A systematic review on electroencephalographic (EEG)-based feature extraction strategies to diagnosis and therapy of attention deficit hyperactivity disorder (ADHD) in children is presented. The analysis is realized at an executive function level to improve the research of neurocorrelates of heterogeneous disorders such as ADHD. The Quality Assessment Tool for Quantitative Studies (QATQS) and field-weighted citation impact metric (Scopus) were used to assess the methodological rigor of the studies and their impact on the scientific community, respectively. One hundred and one articles, concerning the diagnostics and therapy of ADHD children aged from 8 to 14, were collected. Event-related potential components were mainly exploited for executive functions related to the cluster inhibition, whereas band power spectral density is the most considered EEG feature for executive functions related to the cluster working memory. This review identifies the most used (also by rigorous and relevant articles) EEG signal processing strategies for executive function assessment in ADHD.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Eletroencefalografia , Adolescente , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Transtorno do Deficit de Atenção com Hiperatividade/terapia , Criança , Potenciais Evocados/fisiologia , Humanos , Memória de Curto Prazo/fisiologia
2.
Sci Rep ; 12(1): 5857, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35393470

RESUMO

A wearable system for the personalized EEG-based detection of engagement in learning 4.0 is proposed. In particular, the effectiveness of the proposed solution is assessed by means of the classification accuracy in predicting engagement. The system can be used to make an automated teaching platform adaptable to the user, by managing eventual drops in the cognitive and emotional engagement. The effectiveness of the learning process mainly depends on the engagement level of the learner. In case of distraction, lack of interest or superficial participation, the teaching strategy could be personalized by an automatic modulation of contents and communication strategies. The system is validated by an experimental case study on twenty-one students. The experimental task was to learn how a specific human-machine interface works. Both the cognitive and motor skills of participants were involved. De facto standard stimuli, namely (1) cognitive task (Continuous Performance Test), (2) music background (Music Emotion Recognition-MER database), and (3) social feedback (Hermans and De Houwer database), were employed to guarantee a metrologically founded reference. In within-subject approach, the proposed signal processing pipeline (Filter bank, Common Spatial Pattern, and Support Vector Machine), reaches almost 77% average accuracy, in detecting both cognitive and emotional engagement.


Assuntos
Eletroencefalografia , Processamento de Sinais Assistido por Computador , Emoções , Humanos , Estudantes , Máquina de Vetores de Suporte
3.
Sci Rep ; 12(1): 673, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-35027630

RESUMO

A personalized model of the human knee for enhancing the inter-individual reproducibility of a measurement method for monitoring Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) after transdermal delivery is proposed. The model is based on the solution of Maxwell Equations in the electric-quasi-stationary limit via Finite Element Analysis. The dimensions of the custom geometry are estimated on the basis of knee circumference at the patella, body mass index, and sex of each individual. An optimization algorithm allows to find out the electrical parameters of each subject by experimental impedance spectroscopy data. Muscular tissues were characterized anisotropically, by extracting Cole-Cole equation parameters from experimental data acquired with twofold excitation, both transversal and parallel to tissue fibers. A sensitivity and optimization analysis aiming at reducing computational burden in model customization achieved a worst-case reconstruction error lower than 5%. The personalized knee model and the optimization algorithm were validated in vivo by an experimental campaign on thirty volunteers, 67% healthy and 33% affected by knee osteoarthritis (Kellgren-Lawrence grade ranging in [1,4]), with an average error of 3%.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/farmacocinética , Articulação do Joelho/metabolismo , Osteoartrite do Joelho/tratamento farmacológico , Osteoartrite do Joelho/metabolismo , Administração Cutânea , Algoritmos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Modelos Anatômicos , Reprodutibilidade dos Testes
4.
Sci Rep ; 11(1): 5297, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33674657

RESUMO

A method for EEG-based distraction detection during motor-rehabilitation tasks is proposed. A wireless cap guarantees very high wearability with dry electrodes and a low number of channels. Experimental validation is performed on a dataset from 17 volunteers. Different feature extractions from spatial, temporal, and frequency domain and classification strategies were evaluated. The performances of five supervised classifiers in discriminating between attention on pure movement and with distractors were compared. A k-Nearest Neighbors classifier achieved an accuracy of 92.8 ± 1.6%. In this last case, the feature extraction is based on a custom 12 pass-band Filter-Bank (FB) and the Common Spatial Pattern (CSP) algorithm. In particular, the mean Recall of classification (percentage of true positive in distraction detection) is higher than 92% and allows the therapist or an automated system to know when to stimulate the patient's attention for enhancing the therapy effectiveness.


Assuntos
Atenção/fisiologia , Eletroencefalografia/instrumentação , Atividade Motora/fisiologia , Reabilitação Neurológica/instrumentação , Reabilitação Neurológica/métodos , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio/instrumentação , Adulto , Interfaces Cérebro-Computador , Confiabilidade dos Dados , Eletrodos , Feminino , Voluntários Saudáveis , Humanos , Imaginação/fisiologia , Masculino , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Adulto Jovem
5.
Sci Rep ; 10(1): 13656, 2020 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-32788632

RESUMO

An on-chip transducer, for monitoring noninvasively the insulin bio-availability in real time after administration in clinical diabetology, is proposed. The bioavailability is assessed as insulin decrease in situ after administration by means of local impedance measurement. Inter-and-intra individual reproducibility is enhanced by a personalized model, specific for the subject, identified and validated during each insulin administration. Such a real-time noninvasive bioavailability measurement allows to increase the accuracy of insulin bolus administration, by attenuating drawbacks of glycemic swings significantly. In the first part of this paper, the concept, the architecture, and the operation of the transducer, as well as details about its prototype, are illustrated. Then, the metrological characterization and validation are reported in laboratory, in vitro on eggplants, ex vivo on pig abdominal non-perfused muscle, and in vivo on a human subject, using injection as a reference subcutaneous delivery of insulin. Results of significant intra-individual reproducibility in vitro and ex vivo point out noteworthy scenarios for assessing insulin bioavailability in clinical diabetology.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Animais , Disponibilidade Biológica , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patologia , Humanos , Hipoglicemiantes/metabolismo , Injeções Subcutâneas , Insulina/metabolismo , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA