Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 9498, 2020 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-32528027

RESUMO

Multivariate analysis techniques could be used to identify possible intercorrelations in intoxications cases. The statistical analyses used were a multiple logistic regression, multiple correspondence analysis, principal component and hierarchical cluster analysis. Of the 320 samples analysed, 192 samples were positive for some of the investigated toxic agents, of which 100 were positive for ethanol and 131 were positive for other substances. It was possible to group the patients into 3 clusters, which appears 66.5% of this information in the three first factorial axes. On the first axis, the male patients were separated from the female patients. Patients exposed to drugs, between 30 and 39 years old were grouped in the same cluster. On the second factorial axis, patients who were intoxicated with ethanol and who became intoxicated with diazepam were grouped. This work contributed to the mapping of intoxication cases at the Poison Control Centre of the São Paulo city, Brazil (CCI-SP) and serves as an initial study for the creation of a database that could be updated constantly and thus could provide a toxicovigilance system for educational policies.


Assuntos
Bases de Dados Factuais , Centros de Controle de Intoxicações/estatística & dados numéricos , Adulto , Brasil , Feminino , Humanos , Masculino , Análise Multivariada
3.
Forensic Sci Int ; 265: 22-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26826849

RESUMO

Most licit and illicit substances consumed by the nursing mother might be excreted in breast milk, which may cause potential short and long term harmful effects for the breastfed infant. The extraction of substances from this matrix represents an analytical challenge due to its high protein and fat content as well as the fact that its composition changes during postpartum period. The aim of the present study was to develop a liquid phase microextraction (LPME) method for detection of the active substances: cocaine (COC), cocaethylene (CE) and norcocaine (NCOC) in human breast milk using gas chromatography-mass spectrometry (GC-MS). Validation was performed working on spiked human breast milk samples. The limits of detection (LOD) and quantification (LOQ) were of 6 and 12ng/mL, respectively, for all analytes. Calibration curves were linear over a concentration range of 12.0ng/mL-1000ng/mL (r(2)=0.99). No interferences were noticed at the retention times of interest. Within-run and between-run precision was always less or equal to 15 as % relative standard deviation, and bias ranged from 3 to 18%. Forty six milk samples were analyzed. Only one sample was confirmed to be COC positive (138ng/mL) and another one presented COC concentration near the LOD (6ng/mL). This method has shown to be a reliable alternative for the determination of cocaine, cocaethylene and norcocaine in human breast milk in the fields of clinical and forensic toxicology. LPME extraction procedure demonstrated to be a rather promising, low cost and environmental-friendly technique for the purpose of this study.


Assuntos
Cocaína/análise , Leite Humano/química , Detecção do Abuso de Substâncias/métodos , Cocaína/análogos & derivados , Cocaína/sangue , Feminino , Medicina Legal , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Microextração em Fase Líquida , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...