Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Nucl Cardiol ; 30(2): 528-539, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35799039

RESUMO

BACKGROUND: Cadmium-zinc-telluride (CZT)-based detectors exhibit higher diagnostic sensitivity in myocardial perfusion imaging (MPI) than conventional Anger-MPI for detection of coronary artery disease (CAD); however, reduced specificity and diagnostic accuracy of CZT-MPI were observed. This study aims to compare these different camera systems and to examine the degree of inter-rater reproducibility among readers with varying experience in MPI. METHODS: 83 patients who underwent double stress/rest examinations using both a CZT and conventional SPECT cameras within one visit were included. Anonymized and randomized MPI-images were distributed to 15 international readers using a standardized questionnaire. Subsequent coronary angiography findings of ten patients served as a reference for analysis of sensitivity and specificity. RESULTS: Image quality was significantly better in CZT-MPI with significantly lower breast attenuation (P < 0.05). CZT-MPI exhibited higher sensitivity than Anger-MPI (87.5% vs. 62.5%) and significantly reduced specificity (40% vs. 100%). Readers experienced with both camera systems had the highest inter-rater agreement indicating higher reproducibility (CZT 0.54 vs. conv. 0.49, P < 0.05). CONCLUSIONS: Higher diagnostic sensitivity of CZT-MPI offers advantages in detection of CAD yet potentially of at the cost of reduced specificity, therefore it requires special training and a differentiated evaluation approach, especially for non-experienced readers with such camera systems.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Reprodutibilidade dos Testes , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
2.
Nucl Med Commun ; 42(4): 421-428, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33306635

RESUMO

AIM: To assess if digital PET/CT improves liver lesion detectability compared to analog PET/CT in patients with known or suspected liver metastases. MATERIALS AND METHODS: We prospectively included 83 cancer patients, with one or more of these conditions: history of liver metastases, clinical risk of having liver metastases or presence of suspected liver metastases on the first of the two PET/CTs. All patients were consecutively scanned on each PET/CT on the same day after a single [18F]fluorodeoxyglucose dose injection. The order of acquisition was randomly assigned. Three nuclear medicine physicians assessed both PET/CTs by counting the foci of high uptake suspicious of liver metastases. Findings were correlated with appropriate reference standards; 19 patients were excluded from the analysis due to insufficient lesion nature confirmation. The final sample consisted of 64 patients (34 women, mean age 68 ± 12 years). RESULTS: As per-patient analysis, the mean number of liver lesions detected by the digital PET/CT (3.84 ± 4.25) was significantly higher than that detected by the analog PET/CT (2.91 ± 3.31); P < 0.001. Fifty-five patients had a positive PET/CT study for liver lesions. In 26/55 patients (47%), the digital PET/CT detected more lesions; 7/26 patients (27%) had detectable lesions only by the digital system and had <10 mm of diameter. Twenty-nine patients had the same number of liver lesions detected by both systems. In nine patients both PET/CT systems were negative for liver lesions. CONCLUSION: Digital PET/CT offers improved detectability of liver lesions over the analog PET/CT in patients with known or suspected liver metastases.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Computadores , Computadores Analógicos , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos
5.
Eur J Nucl Med Mol Imaging ; 47(3): 572-578, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31919634

RESUMO

OBJECTIVE: To compare detectability of hyperfunctioning parathyroid tissue (HPT) by digital and analog 18F-fluorocholine PET/CT in patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT. MATERIALS AND METHODS: Thirty-three patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT were prospectively included. All patients accepted to be scanned by digital and analog PET/CT in the same imaging session after a single injection of 18F-fluorocholine. Three nuclear medicine physicians evaluated the digital and analog PET/CT datasets to assess the detection rate of HPT. Maximum standard uptake values (SUVmax) of HPT and locoregional lymph nodes were measured in both systems. RESULTS: HPT was detected in 30/33 patients by the digital system, whereas it was detected in 22/33 patients by the analog system (p < 0.01). Moreover, in 21 of these 33 patients, both systems detected one focal 18F-fluorocholine uptake, and in one patient the digital system detected two foci. Histopathology demonstrated HPT in 32 patients and it was inconclusive in one patient. The digital PET/CT detected HPT in 29 of the 32 patients, and the analog system in 22 of the 32 (p < 0.01). All HPT suspected lesions resected and detected only by the digital system (n = 8) were < 10 mm (7.5 ± 1.3 mm), while those detected by both systems (n = 22) were > 10 mm (13 ± 3.8 mm). SUVmax of HPT lesions was significantly higher than SUVmax of locoregional lymph node independently of the PET/CT system used (4.5 ± 1.9 vs. 2.9 ± 1.3, p < 0.0001). CONCLUSIONS: Digital PET/CT offers superior performance over analog system in patients with suspected HPT and previous negative/inconclusive imaging examinations, particularly in sub-centimeter lesions. SUVmax can help in the differentiation between HTP and locoregional lymph nodes.


Assuntos
Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Colina/análogos & derivados , Humanos , Glândulas Paratireoides , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecnécio Tc 99m Sestamibi
7.
Eur J Nucl Med Mol Imaging ; 46(5): 1204, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30739142

RESUMO

The article Digital vs. analog PET/CT: intra-subject comparison of the SUVmax in target lesions and reference regions, written by Francisco Fuentes-Ocampo, Diego Alfonso López-Mora, Albert Flotats, Gabriela Paillahueque.

8.
Eur J Nucl Med Mol Imaging ; 46(8): 1745-1750, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30617960

RESUMO

PURPOSE: The purpose of this study was to assess whether digital photon counting technology in digital PET/CT influences the quantification of SUVmax in target lesions and regions of reference compared to analog PET/CT before an interchangeable use of either system in follow up studies. METHODS: From January to June of 2018, 100 oncological patients underwent successive PET/CT imaging with digital and analog systems in the same day. Fifty-eight patients underwent analog imaging first and digital imaging thereafter, and 42 patients the other way round. SUVmax was measured in reference regions (liver and mediastinal blood pool) and in the most metabolically active target lesion in each patient. According to the sequence order of PET/CT acquisition, two groups of SUVmax values were obtained, i.e. group 1: analog PET/CT performed first; group 2: digital PET/CT performed first. RESULTS: Mean SUVmax in the total sample (regardless of the order of PET/CT acquisition) in the target lesions with the analog PET/CT was 8.14 ± 6.39 and the digital 9.97 ± 6.14 (P = 0.000). Total mean SUVmax in the liver with the analog was 4.39 ± 2.59 and the digital 4.46 ± 3.18 (P = 0.477). Total mean SUVmax in the mediastinal blood pool with the analog was 2.30 ± 0.67 and the digital 2.54 ± 0.74 (P = 0.000). Group 1: mean SUVmax in the target lesions with the analog system was 6.64 ± 4.71 and the digital 9.48 ± 5.60 (P = 0.000). Mean liver SUVmax with the analog was 4.70 ± 2.90 and the digital 4.80 ± 3.72 (P = 0.088). Mediastinal blood pool SUVmax with the analog was 2.33 ± 0.66 and the digital 2.45 ± 0.73 (P = 0.041). Group 2: mean SUVmax in target lesions with the digital system was 10.63 ± 6.88 and the analog 10.16 ± 7.76 (P = 0.046). Mean liver SUVmax with the digital was 3.99 ± 2.20 and the analog 3.96 ± 2.04 (P = 0.218). Mediastinal blood pool SUVmax with the digital was 2.66 ± 0.75 and the analog 2.27 ± 0.68 (P = 0.000). No significant differences between both time delays were found. CONCLUSIONS: Improved photon counting technology in the digital PET/CT, and the effect of delayed increased uptake and retention significantly increases SUVmax values. This has to be taken into account before interchangeable use of either system in follow up studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Interpretação Estatística de Dados , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Fígado/diagnóstico por imagem , Masculino , Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Compostos Radiofarmacêuticos/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes
9.
Eur J Nucl Med Mol Imaging ; 46(6): 1383-1390, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30631910

RESUMO

OBJECTIVE: The purpose of this study was to compare image quality and lesion detection capability between a digital and an analog PET/CT system in oncological patients. MATERIALS AND METHODS: One hundred oncological patients (62 men, 38 women; mean age of 65 ± 12 years) were prospectively included from January-June 2018. All patients, who accepted to be scanned by two systems, consecutively underwent a single day, dual imaging protocol (digital and analog PET/CT). Three nuclear medicine physicians evaluated image quality using a 4-point scale (-1, poor; 0, fair; 1, good; 2, excellent) and detection capability by counting the number of lesions with increased radiotracer uptake. Differences were considered significant for a p value <0.05. RESULTS: Improved image quality in the digital over the analog system was observed in 54% of the patients (p = 0.05, 95% CI, 44.2-63.5). The percentage of interrater concordance in lesion detection capability between the digital and analog systems was 97%, with an interrater measure agreement of κ = 0.901 (p < 0.0001). Although there was no significant difference in the total number of lesions detected by the two systems (digital: 5.03 ± 10.6 vs. analog: 4.53 ± 10.29; p = 0.7), the digital system detected more lesions in 22 of 83 of PET+ patients (26.5%) (p = 0.05, 95% CI, 17.9-36.7). In these 22 patients, all lesions detected by the digital PET/CT (and not by the analog PET/CT) were < 10 mm. CONCLUSION: Digital PET/CT offers improved image quality and lesion detection capability over the analog PET/CT in oncological patients, and even better for sub-centimeter lesions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Diagnóstico por Computador , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Compostos Radiofarmacêuticos
10.
Med. leg. Costa Rica ; 29(2): 19-38, sept. 2012. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: lil-657741

RESUMO

Los estudiantes que ingresan a la Escuela de Medicina son personas que pasarán los próximos años de su vida preparándose para entender la composición, la anatomía y la fisiología tanto normal como patológica del cuerpo humano con el fin de luego, aplicar ese conocimiento en el tratamiento de sus pacientes. Sin embargo, ser estudiante de Medicina se ha descrito como un extenuante proceso en el cual los jóvenes sufren alteraciones notables en sus horas de sueño, niveles de estrés, presión y fustración emocional e incluso depresión. Esta investigación se llevó a cabo para identificar en una población de estudiantes de segundo semestre de segundo año de Medicina de la Universidad de Costa Rica, el deterioro cognitivo que puede tener dicho estilo de vida y cómo influye en la capacidad de aprendizaje y los resultados que estos pueden obtener. A través de la figura compleja de Rey-Osterrieth y la prueba MoCA (Montreal Cognitive Assesment) se evaluó la muestra en dos oportunidades distintas: al encontrarse los estudiantes en un período de evaluación normal y con un nivel de cansancio notable tras un período de evaluación más intenso. Los datos obtenidos comprobaron que efectivamente existe un deterioro en el rendimiento y las capacidades cognitivas de los jóvenes...


Assuntos
Humanos , Masculino , Feminino , Distúrbios do Início e da Manutenção do Sono/complicações , Estresse Psicológico/complicações , Privação do Sono/complicações , Privação do Sono/fisiopatologia , Estudantes de Medicina , Transtornos do Sono-Vigília/complicações , Transtornos do Sono-Vigília/fisiopatologia , Transtornos Cognitivos/etiologia , Costa Rica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...