Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 15(5): e39164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37332405

RESUMO

AIMS: Immediate bleeding after cold snare polypectomy (CSP) for colorectal polyps might interfere with confirmation of residuals and prolong the time required for resection. We investigated whether submucosal epinephrine-added saline injection reduces the time required for the CSP procedure. METHODS: We conducted a single-center, prospective, randomized controlled trial (clinical trial registration number: UMIN000046770). Patients with colorectal polyps ≤ 10 mm were randomly allocated to either CSP with epinephrine-added submucosal injection (CEMR group) or conventional CSP (CSP group). The primary outcome was the time required for resection defined as the time from the initiation of resection (the first insertion of the snare in the CSP group or the injection needle in the CEMR group) to the end of resection (confirming complete resection endoscopically after recognizing the cessation of immediate bleeding) in each lesion, and the secondary outcome was the time to spontaneous cessation of immediate bleeding after resection defined as the time from ensnaring the lesion to confirming the spontaneous cessation of immediate bleeding. RESULTS: A total of 126 patients were randomly assigned. Finally, 261 lesions in 118 patients (CEMR group, n = 59; CSP group, n = 59) were analyzed. The time required for resection calculated using the least-square mean was significantly shorter in the CEMR group (106.3 s, 95% CI 97.5 to 115.4 s) than in the CSP group (130.9 s, 95% CI 121.2 to 140.7 s) (P < 0.001). The time to spontaneous cessation of immediate bleeding was also significantly shorter in the CEMR group (20.4 s, 95% CI 14.3 to 26.5 s) than in the CSP group (74.2 s, 95% CI 67.6 to 80.7 s) (P < 0.001). Neither group had cases requiring hemostasis, perforation, or delayed bleeding. CONCLUSIONS: CEMR shortened the time for resection by shortening the time to cessation of immediate bleeding compared with conventional CSP in colorectal polyps ≤ 10 mm.

2.
Cureus ; 14(12): e32713, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36686130

RESUMO

AIM: Factors that may make endoscopic submucosal dissection (ESD) difficult for operators have been evaluated according to results based on the performance of experienced endoscopists. This study aimed to verify the predictors of difficult gastric ESD for ESD beginners. METHODS: From January 2015 to December 2021, 466 superficial gastric neoplasms were treated with ESD at Showa University Hospital. Excluding 103 lesions that performed ESD by experts who experienced more than 80 ESDs, a total of 363 lesions were included. The lesions were divided into two groups according to the ESD performance experience of the operator: ESD beginner (EB; ESD experience≤30 cases) and ESD intermediate (EI; ESD experience 31-80 cases) groups. Relationships between difficult ESD (having at least one of the following: procedure time>60 min, incomplete resection, change of operator, and occurrence of severe complications) and clinicopathological findings of the lesion were analyzed. RESULTS: The complete resection rates and the difficult ESD rates in the EB and EI groups were 99.3%, 94.8%, and 61.2%, 50.7%, respectively. In the EB group, univariate analysis showed that difficult ESD rate was significantly higher in the non-lower third lesions, the lesser curvature lesions, and cancerous lesions. In the EI group, univariate analysis showed that difficult ESD rate was significantly higher in lesion with ≥20 mm size, lesser curvature lesions, lesions with ulcers, and submucosal cancers. Multivariate analysis showed that the lesser curvature location and cancerous histology in the EB group and ≥20 mm lesion size, the lesser curvature location and submucosal invasion in the EI group were independent predictors of difficult ESD. CONCLUSIONS: The lesser curvature location is recognized as independent ESD difficulty factor for both beginners and intermediates. Cases with lesions located in the lesser curvature should not be selected for gastric ESD training by beginners.

3.
Rev Sci Instrum ; 90(5): 054101, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31153273

RESUMO

We have developed a handling-free mounting method for X-ray crystallography of protein crystals at room temperatures-the glass capillary method. In this method, crystals were nucleated and grown on the capillary walls, and then, growth solutions were gently removed. The procedures for collecting data on the crystals were conducted by simply setting the capillary on the goniometer of a synchrotron beamline without touching the crystals. Crystal quality was characterized using mosaicity, resolution at I/σ(I) = 2, I/σ(I) at resolution = 2.0 Å, Rmerge, and completeness. Wilson plots were also used to characterize the quality of crystals. In particular, all samples showed very low mosaicity; the handling-free method successfully retained their low mosaicity and effectively maintained the crystal quality.


Assuntos
Aldose-Cetose Isomerases/química , Cristalografia por Raios X/instrumentação , Síncrotrons , Temperatura
4.
Rev Sci Instrum ; 86(8): 083704, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26329200

RESUMO

The normal growth rates of the {110} faces of tetragonal hen egg-white lysozyme crystals, R, were measured as a function of the supersaturation σ parameter using a reflection type interferometer under µG at the International Space Station (NanoStep Project). Since water slightly evaporated from in situ observation cells during a long-term space station experiment for several months, equilibrium temperature T(e) changed, and the actual σ, however, significantly increased mainly due to the increase in salt concentration C(s). To correct σ, the actual C(s) and protein concentration C(p), which correctly represent the measured T(e) value in space, were first calculated. Second, a new solubility curve with the corrected C(s) was plotted. Finally, the revised σ was obtained from the new solubility curve. This correction method successfully revealed that the 2.8% water was evaporated from the solution, leading to 2.8% increase in the C(s) and C(p) of the solution.


Assuntos
Meio Ambiente Extraterreno , Muramidase/química , Astronave , Temperatura , Água/química , Cristalização , Solubilidade , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...