Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiol Cases ; 27(3): 132-135, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36910034

RESUMO

The endovascular treatment using a drug-coated balloon (DCB) reduces restenosis and target vessel re-vascularization rate in patients with peripheral artery disease such as claudication and chronic limb-threatening ischemia (CLTI). However, its safety and efficacy in patients with post-below-knee amputation remain unknown. We had a patient with CLTI and a history of below-knee amputation, who suffered a no-flow phenomenon following DCB angioplasty that required above-knee amputation. DCB angioplasty might not be appropriate for those with severe CLTI and histories of amputation. Learning objective: The present report describes the risk of endovascular treatment using a drug-coated balloon for chronic limb-threatening ischemia patients with a below-knee amputated limb.

2.
Eur Heart J Case Rep ; 6(9): ytac370, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36147932

RESUMO

Background: Secondary mitral regurgitation (SMR) is a major comorbidity in patients with heart failure with reduced ejection fraction (HFrEF). Transcatheter edge-to-edge repair (TEER) using the MitraClip™ system is a promising tool for selected patients with SMR and HFrEF. Durable success using this system in patients who have advanced heart failure and unsuitable anatomy remains a clinical challenge. Case summary: Three patients aged 67-72 years with HFrEF on inotropic support successfully underwent Impella®-assisted TEER at our centre. Following the procedure, two patients were able to be weaned off inotropic support and were discharged, while one patient expired during the index hospitalization. Discussion: Impella®-assisted TEER may be a feasible strategy for patients with SMR and HFrEF with unstable haemodynamics particularly when cardiac replacement therapy is not applicable.

3.
Medicina (Kaunas) ; 58(2)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35208635

RESUMO

Cancer therapeutics-related cardiac dysfunction is currently of great concern as one of the pivotal therapeutic targets of onco-cardiology. Only a few studies have reported the occurrence of heart failure following the administration of osimertinib, a third-generation epidermal growth factor receptor (EGFR)-tyrosine kinase inhibitor for EGFR mutation-positive advanced non-small cell lung cancer. We report on a 74-year-old woman with osimertinib-induced advanced heart failure with reduced ejection fraction, which was treated by the temporal termination of osimertinib and neurohormonal blocker therapy, as well as heart rate modulation therapy using ivabradine. Despite osimertinib-induced heart failure being relatively rare, aggressive neurohormonal blocker therapy using ivabradine if applicable, as well as the temporal termination of osimertinib, might be a promising therapeutic strategy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Insuficiência Cardíaca , Neoplasias Pulmonares , Acrilamidas/efeitos adversos , Idoso , Compostos de Anilina , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Feminino , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Mutação , Inibidores de Proteínas Quinases/efeitos adversos
4.
Int Heart J ; 63(1): 73-76, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095079

RESUMO

Remote dielectric sensing (ReDS) is a recently introduced non-invasive electromagnetic-based device used to quantify lung fluid levels. Nevertheless, its inter-rater and intra-rater reliability remain uncertain. In 10 healthy volunteers, ReDS values were measured three times successively by the officially trained expert examiner to validate intra-rater reliability. Similar measures were performed by a total of three examiners to validate inter-rater reliability. Intra-class correlation (ICC) was applied to validate each reliability. Ten healthy volunteers [median 34 (32, 40) years old, 10 men, body mass index 23.0 (21.2, 23.9) ] were included. Median ReDS value was 28% (25%, 31%). For the intra-rater reliability, ICC (1, 1) and ICC (1, 3) were 0.966 and 0.988, respectively (P < 0.001). For the inter-rater reliability, ICC (2, 1) and ICC (2, 3) were 0.683 and 0.866, respectively (P < 0.001). Given almost perfect intra-rater reliability, an examiner does not need to repeat ReDS measurement. Given substantial inter-rater reliability, ReDS measurements had better be measured by multiple examiners if possible.


Assuntos
Água Extravascular Pulmonar , Pulmão , Tecnologia de Sensoriamento Remoto/instrumentação , Adulto , Estudos de Coortes , Humanos , Masculino , Variações Dependentes do Observador , Estudo de Prova de Conceito , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA