1.
BMC Med Imaging ; 23(1): 5, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624404

RESUMO

PURPOSE: To evaluate whether deep learning reconstruction (DLR) accelerates the acquisition of 1.5-T magnetic resonance imaging (MRI) knee data without image deterioration. MATERIALS AND METHODS: Twenty-one healthy volunteers underwent MRI of the right knee on a 1.5-T MRI scanner. Proton-density-weighted images with one or four numbers of signal averages (NSAs) were obtained via compressed sensing, and DLR was applied to the images with 1 NSA to obtain 1NSA-DLR images. The 1NSA-DLR and 4NSA images were compared objectively (by deriving the signal-to-noise ratios of the lateral and the medial menisci and the contrast-to-noise ratios of the lateral and the medial menisci and articular cartilages) and subjectively (in terms of the visibility of the anterior cruciate ligament, the medial collateral ligament, the medial and lateral menisci, and bone) and in terms of image noise, artifacts, and overall diagnostic acceptability. The paired t-test and Wilcoxon signed-rank test were used for statistical analyses. RESULTS: The 1NSA-DLR images were obtained within 100 s. The signal-to-noise ratios (lateral: 3.27 ± 0.30 vs. 1.90 ± 0.13, medial: 2.71 ± 0.24 vs. 1.80 ± 0.15, both p < 0.001) and contrast-to-noise ratios (lateral: 2.61 ± 0.51 vs. 2.18 ± 0.58, medial 2.19 ± 0.32 vs. 1.97 ± 0.36, both p < 0.001) were significantly higher for 1NSA-DLR than 4NSA images. Subjectively, all anatomical structures (except bone) were significantly clearer on the 1NSA-DLR than on the 4NSA images. Also, in the former images, the noise was lower, and the overall diagnostic acceptability was higher. CONCLUSION: Compared with the 4NSA images, the 1NSA-DLR images exhibited less noise, higher overall image quality, and allowed more precise visualization of the menisci and ligaments.


Assuntos
Aprendizado Profundo , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Aceleração
2.
Eur Radiol ; 33(7): 5028-5036, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36719498

RESUMO

OBJECTIVES: To establish a CT lymphangiography method in mice via direct lymph node puncture. METHODS: We injected healthy mice (n = 8) with 50 µl of water-soluble iodine contrast agent (iomeprol; iodine concentration, 350 mg/mL) subcutaneously into the left-rear foot pad (interstitial injection) and 20 µl of the same contrast agent directly into the popliteal lymph node (direct puncture) 2 days later. Additionally, we performed interstitial MR lymphangiography on eight mice as a control group. We calculated the contrast ratio for each lymph node and visually assessed the depiction of lymph nodes and lymphatic vessels on a three-point scale. RESULTS: The contrast ratios of 2-min post-injection images of sacral and lumbar-aortic lymph nodes were 20.7 ± 16.6 (average ± standard deviation) and 17.1 ± 12.0 in the direct puncture group, which were significantly higher than those detected in the CT or MR interstitial lymphangiography groups (average, 1.8-3.6; p = 0.008-0.019). The visual assessment scores for sacral lymph nodes, lumbar-aortic lymph nodes, and cisterna chyli were significantly better in the direct puncture group than in the CT interstitial injection group (p = 0.036, 0.009 and 0.001, respectively). The lymphatic vessels between these structures were significantly better scored in direct puncture group than in the CT or MR interstitial lymphangiography groups at 2 min after injection (all p ≤ 0.05). CONCLUSIONS: In CT lymphangiography in mice, the direct lymph node puncture provides a better delineation of the lymphatic pathways than the CT/MR interstitial injection method. KEY POINTS: • The contrast ratios of 2-min post-injection images in the direct CT lymphangiography group were significantly higher than those of CT/MR interstitial lymphangiography groups. • The visibility of lymphatic vessels in subjective analysis in the direct CT lymphangiography group was significantly better in the direct puncture group than in the CT/MR interstitial lymphangiography groups. • CT lymphangiography with direct lymph node puncture can provide excellent lymphatic delineation with contrast being maximum at 2 min after injection.


Assuntos
Iodo , Linfografia , Animais , Camundongos , Linfografia/métodos , Meios de Contraste/farmacologia , Estudos de Viabilidade , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada por Raios X
3.
Magn Reson Imaging ; 92: 169-179, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35772583

RESUMO

PURPOSE: To assess the possibility of reducing the image acquisition time for diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) by denoising with deep learning-based reconstruction (dDLR). METHODS: Seventeen patients with prostate cancer who underwent DWIBS by 1.5 T magnetic resonance imaging with a number of excitations of 2 (NEX2) and 8 (NEX8) were prospectively enrolled. The NEX2 image data were processed by dDLR (dDLR-NEX2), and the NEX2, dDLR-NEX2, and NEX8 image data were analyzed. In qualitative analysis, two radiologists rated the perceived coarseness, conspicuity of metastatic lesions (lymph nodes and bone), and overall image quality. The contrast-to-noise ratios (CNRs), contrast ratios, and mean apparent diffusion coefficients (ADCs) of metastatic lesions were calculated in a quantitative analysis. RESULTS: The image acquisition time of NEX2 was 2.8 times shorter than that of NEX8 (3 min 30 s vs 9 min 48 s). The perceived coarseness and overall image quality scores reported by both readers were significantly higher for dDLR-NEX2 than for NEX2 (P = 0.005-0.040). There was no significant difference between dDLR-NEX2 and NEX8 in the qualitative analysis. The CNR of bone metastasis was significantly greater for dDLR-NEX2 than for NEX2 and NEX8 (P = 0.012 for both comparisons). The contrast ratios and mean ADCs were not significantly different among the three image types. CONCLUSIONS: dDLR improved the image quality of DWIBS with NEX2. In the context of lymph node and bone metastasis evaluation with DWIBS in patients with prostate cancer, dDLR-NEX2 has potential to be an alternative to NEX8 and reduce the image acquisition time.


Assuntos
Neoplasias Ósseas , Aprendizado Profundo , Neoplasias da Próstata , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Imagem de Difusão por Ressonância Magnética/métodos , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias da Próstata/diagnóstico por imagem
4.
Radiol Case Rep ; 16(7): 1874-1877, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34113409

RESUMO

Fat-forming variant of solitary fibrous tumor (SFT) is a rare mesenchymal neoplasm. Here we report the case of a 33-year-old woman who developed pain and muscle weakness from the posterior aspect of the right hip to lower extremity. Imaging examinations revealed a mass with fatty components and hypervascular solid components filling the sacral spinal canal and sacral foramen. The sacral mass was resected and histological examination of the specimens revealed patternless proliferation of short spindle-shaped cells with staghorn blood vessels. A number of mature adipocyte-like cells were also observed. The tumor cells were positive for STAT6 and the nuclei of the adipocytes were also positive, which was diagnostic for fat-forming SFT.

5.
Radiographics ; 41(1): 224-248, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33216673

RESUMO

Radiation therapy (RT) continues to play a central role as an effective therapeutic modality for a variety of tumors and vascular malformations in the central nervous system. Although the planning and delivery techniques of RT have evolved substantially during the past few decades, the structures surrounding the target lesion are inevitably exposed to radiation. A wide variety of radiation-induced changes may be observed at posttreatment imaging, which may be confusing when interpreting images. Histopathologically, radiation can have deleterious effects on the vascular endothelial cells as well as on neuroglial cells and their precursors. In addition, radiation induces oxidative stress and inflammation, leading to a cycle of further cellular toxic effects and tissue damage. On the basis of the time of expression, radiation-induced injury can be divided into three phases: acute, early delayed, and late delayed. Acute and early delayed injuries are usually transient and reversible, whereas late delayed injuries are generally irreversible. The authors provide a comprehensive review of the timeline and expected imaging appearances after RT, including the characteristic imaging features after RT with concomitant chemotherapy. Specific topics discussed are imaging features that help distinguish expected posttreatment changes from recurrent disease, followed by a discussion on the role of advanced imaging techniques. Knowledge of the RT plan, the amount of normal structures included, the location of the target lesion, and the amount of time elapsed since RT is highly important at follow-up imaging, and the reporting radiologist should be able to recognize the characteristic imaging features after RT and differentiate these findings from tumor recurrence. ©RSNA, 2020.


Assuntos
Células Endoteliais , Lesões por Radiação , Sistema Nervoso Central , Diagnóstico por Imagem , Humanos , Lesões por Radiação/diagnóstico por imagem
6.
MAGMA ; 33(5): 701-712, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32130567

RESUMO

OBJECTIVE: To investigate whether a SPIO-labeling technique could enable MR visualization of the treatment margin after X-irradiation at a single dose of 30 Gy. MATERIALS AND METHODS: Fifteen rats bearing N1-S1 hepatoma in either the left (group 1) or right (group 2) liver lobe were examined. Four hours after systemic SPIO administration, the left lobe was selectively irradiated at 30 Gy. Liver T2* maps were acquired 7 days later using a 9.4 T scanner. The livers were excised and examined histologically. RESULTS: The irradiated area showed T2*-weighted hypointensity with significantly shorter T2* values than those in the non-irradiated area (p < 0.001). Tumors in group 1 completely disappeared, whereas tumors in group 2 had grown outside the T2*-weighted hypointensity by up to ~ 2.3 times that at baseline. Group 1 showed significantly higher probability of tumor regression than group 2 (p = 0.048). Histologically, iron deposition was heavier in irradiated areas than in non-irradiated areas. DISCUSSION: Even at a single dose of 30 Gy, which is a slightly higher dose than can be used clinically in stereotactic body radiotherapy, MR visualization of the treatment margin was achieved, because tumors showed significant growth outside the T2*-hypointense areas. In contrast, tumors disappeared inside the T2*-hypointense areas.


Assuntos
Neoplasias Hepáticas , Nanopartículas de Magnetita , Animais , Meios de Contraste , Dextranos , Compostos Férricos , Fígado , Imageamento por Ressonância Magnética , Ratos
7.
Neuroradiology ; 60(11): 1141-1150, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30143820

RESUMO

PURPOSE: To evaluate the effects of the single-energy metal artifact reduction (SEMAR) algorithm on image quality of cerebral CT and CT angiography (CTA) for patients who underwent intracranial aneurysm coiling. METHODS: Twenty patients underwent cerebral CT and CTA using a 320-detector row CT after intracranial aneurysm coiling. Images with and without application of the SEMAR algorithm (SEMAR CT and standard CT images, respectively) were reconstructed for each patient. The images were qualitatively assessed by two independent radiologists in a blinded manner for the depiction of anatomical structures around the coil, delineation of the arteries around the coil, and the depiction of the status of coiled aneurysms. Artifact strength was quantitatively assessed by measuring the standard deviation of attenuation values around the coil. RESULTS: The strength of artifacts measured in SEMAR CT images was significantly lower than that in standard CT images (25.7 ± 10.2 H.U. vs. 80.4 ± 67.2 H.U., p < 0.01, Student's paired t test). SEMAR CT images were significantly improved compared with standard CT images in the depiction of anatomical structures around the coil (p < 0.01, the sign test), delineation of the arteries around the coil (p < 0.01), and the depiction of the status of coiled aneurysms (p < 0.01). CONCLUSION: The SEMAR algorithm significantly reduces metal artifacts from intracranial aneurysm coiling and improves visualization of anatomical structures and arteries around the coil, and depiction of the status of coiled aneurysms on post-interventional cerebral CT.


Assuntos
Algoritmos , Artefatos , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Acta Radiol ; 58(9): 1085-1093, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28068822

RESUMO

Background Abdominal computed tomography (CT) without arm elevation is associated with degraded image quality due to streak artifacts. Purpose To compare the degree of streak artifacts in abdominal CT images without arm elevation between full iterative reconstruction (IR), hybrid IR, and filtered back projection (FBP) using two commercially available scanners. Material and Methods First, a phantom study simulating CT examination without arm elevation was performed. Second, unenhanced axial images of 33 patients (17 and 16 patients for each vendor) who underwent CT without arm elevation were reconstructed with full IR, hybrid IR and FBP. A radiologist placed 50 parallel lines with lengths of 50 pixels vertical to the streaks and quantitatively evaluated the images for streak artifacts in the phantom study. Two radiologists evaluated the images of patients for streak artifacts (on the liver and the kidney) and diagnostic acceptability using a four-point scale. Results The phantom study indicated that full IR algorithms were more effective than FBP in reducing streak artifacts. In the clinical patient study, streak artifacts were significantly more reduced with full IR compared with FBP in both the liver and kidney ( P < 0.012). Streak artifact reduction was limited with hybrid IR. Model-based iterative reconstruction (MBIR) (one of the full IR algorithms) provided diagnostically more acceptable image quality ( P < 0.016) compared with FBP. Conclusion In abdominal CT without arm elevation, full IR enabled a more efficient streak artifact reduction compared with FBP and MBIR was associated with diagnostically more acceptable images.


Assuntos
Abdome/diagnóstico por imagem , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Braço , Meios de Contraste , Feminino , Humanos , Masculino , Posicionamento do Paciente , Imagens de Fantasmas , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
J Magn Reson Imaging ; 45(1): 303-312, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27373786

RESUMO

PURPOSE: To determine whether T2*-weighted MRI has the ability to visualize the irradiated liver parenchyma and liver tumor after irradiation to the previously superparamagnetic iron oxide (SPIO)-accumulated liver. MATERIALS AND METHODS: We examined 24 liver tumor-bearing rats. Nine rats (Group 1) received 20 µmol Fe/kg SPIO and subsequent 70-Gy irradiation to the tumor-bearing liver lobe. Four rats (Group 2) received SPIO and sham irradiation. Six rats (Group 3) received saline and irradiation. Finally, five rats (Group 4) received saline and sham irradiation. We acquired sequential 3 Tesla T2*-weighted images of the liver on day 7, and assessed MR image findings including signal intensity of the tumors and tumor-bearing liver lobes. RESULTS: In six rats in Group 1, tumors shrunk by 39-100% (303-0 mm3 ), and severely, well-defined hypointense irradiated areas were observed. In the other two rats, tumors enlarged by 25 and 172% (595 and 1148 mm3 ), and hypointense rings surrounded the tumors. The normalized relative signal intensity of the irradiated areas was significantly lower than that of the tumor (0.53 ± 0.06 versus 0.94 ± 0.06; P < 0.05). The severely, well-defined hypointense areas were not observed in the other groups. Histologically, necrotic regions dominated and minimal nonnecrotic tumor cells remained in irradiated areas. The number of CD68-positive cells was higher in irradiated areas than in nonirradiated areas. CONCLUSION: T2*-weighted MR imaging visualized the irradiated liver parenchyma as markedly, well-defined hypointense areas and liver cancer lesions as hyperintense areas only when SPIO was administered before irradiation. The visualization of the hypointense area was associated with tumor regression after irradiation. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:303-312.


Assuntos
Dextranos/farmacocinética , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/radioterapia , Fígado/diagnóstico por imagem , Fígado/metabolismo , Imagem Multimodal/métodos , Animais , Biomarcadores/metabolismo , Linhagem Celular Tumoral , Meios de Contraste/farmacocinética , Feminino , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Nanopartículas de Magnetita , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Resultado do Tratamento
10.
Invest Radiol ; 50(6): 376-83, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25695671

RESUMO

OBJECTIVE: The objective of this study was to demonstrate experimentally that radiofrequency ablation (RFA) of ferucarbotran-accumulated healthy liver tissues causes excess iron deposition in the ablated liver tissues on postablation days and produces sustained T2*-weighted low signals indicative of ablative margins surrounding hepatic tumors. MATERIALS AND METHODS: We conducted 3 experiments using 30 rats. In experiment 1, we administered either ferucarbotran (n = 6) or saline (n = 4), acquired T2*-weighted images (T2*-WIs) of the liver by using a 3-T magnetic resonance scanner, and subsequently performed RFA of healthy liver lobes. We acquired follow-up T2*-WIs up to day 7 and histologically analyzed the liver specimens. In another 4 rats, we performed sham operation, instead of RFA, in ferucarbotran-accumulated liver lobes, followed by the same image acquisition and histological analysis. In experiment 2, we administered 59Fe-labeled ferucarbotran, subsequently performed either RFA (n = 4) or sham operation (n = 4) in the liver, and acquired autoradiograms of the liver specimens on day 7. In experiment 3, we conducted RFA treatment for 8 rats bearing orthotopic hepatic tumors after ferucarbotran administration and monitored tumor growth by using serial T2*-WIs. RESULTS: On days 4 and 7 of the experiment 1, T2*-WIs of 6 rats with systemic ferucarbotran administration and subsequent hepatic RFA showed low-signal regions indicative of ablated liver tissues, whereas high-signal areas were seen in 4 saline-administered rats. Neither high nor low signal areas were detected in 4 sham-operated rats. Histologically, larger amounts of iron were observed in the RFA-induced necrotic liver tissues in the ferucarbotran-administered rats than in the saline-administered-rats. The 59Fe autoradiography of the rats in experiment 2 revealed accumulation of ferucarbotran-derived iron in necrotic liver tissues. Among 6 hepatic tumors grown in 6 rats of the experiment 3, a total of 4 tumors were stable in size, but the other 2 increased markedly on day 7. Retrospectively, T2*-WIs showed the former tumor sites surrounded completely by low-signal areas on day 4. CONCLUSIONS: The RFA of ferucarbotran-accumulated healthy liver tissues in the rats caused excess iron deposition in the ablated liver tissues and produced sustained T2*-weighted hypointense regions. Similar hypointense regions surrounding hepatic tumors were indicative of ablative margins.


Assuntos
Ablação por Cateter , Meios de Contraste/metabolismo , Dextranos/metabolismo , Ferro/metabolismo , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Animais , Modelos Animais de Doenças , Feminino , Aumento da Imagem , Fígado/patologia , Fígado/cirurgia , Nanopartículas de Magnetita , Ratos , Ratos Sprague-Dawley
11.
PLoS One ; 9(4): e94945, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24743153

RESUMO

Due to their small size, lung tumors in rodents are typically investigated using high-field magnetic resonance (MR) systems (4.7 T or higher) to achieve higher signal-to-noise ratios, although low-field MR systems are less sensitive to susceptibility artifacts caused by air in the lung. We investigated the feasibility of detecting lung tumors in living, freely breathing mice with a 1-T compact permanent magnet MR system. In total, 4 mice were used, and MR images of mouse lungs were acquired using a T1-weighted three-dimensional fast low-angle shot sequence without cardiac or respiratory gating. The delineation and size of lung tumors were assessed and compared with histopathological findings. Submillimeter lesions were demonstrated as hyperintense, relative to the surrounding lung parenchyma, and were delineated clearly. Among the 13 lesions validated in histopathological sections, 11 were detected in MR images; the MR detection rate was thus 84.6%. A strong correlation was obtained in size measurements between MR images and histological sections. Thus, a dedicated low-field MR system can be used to detect lung tumors in living mice noninvasively without gating.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Neoplasias Experimentais/diagnóstico por imagem , Animais , Feminino , Camundongos , Radiografia , Sensibilidade e Especificidade
12.
Jpn J Radiol ; 32(5): 282-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24531980

RESUMO

Erdheim-Chester disease (ECD) is a non-Langerhans cell histiocytosis. Herein we report a case of a 49-year-old woman who developed bilateral knee pain. Imaging procedures revealed multiple long bone lesions and a well-defined 18F-fluorodeoxyglucose-avid mass in the left breast. The breast mass was resected, and an open biopsy was performed on the right femoral lesion. Both specimens revealed involvement by histiocytic infiltrates with features suggestive of ECD. The BRAF V600E mutation was detected by DNA sequencing and immunohistochemistry.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/genética , Doença de Erdheim-Chester/diagnóstico , Doença de Erdheim-Chester/genética , Proteínas Proto-Oncogênicas B-raf/genética , Biópsia , Neoplasias da Mama/cirurgia , Diagnóstico Diferencial , Doença de Erdheim-Chester/cirurgia , Feminino , Fluordesoxiglucose F18 , Humanos , Imuno-Histoquímica , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
13.
MAGMA ; 27(6): 501-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24570338

RESUMO

OBJECT: To determine whether superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging could demonstrate signal recovery delay in irradiated areas of rat livers. We also investigated the relationship between MR imaging and histological findings. MATERIALS AND METHODS: Twelve rats received 20 µmol iron/kg of SPIO followed by X-irradiation to the right upper abdomen 4 h later. Radiation doses were 0, 50 and 70 Gy. Hepatic signals were assessed on unenhanced T 2 (*) -weighted images for up to 7 days using a 9.4-Tesla scanner. The livers were excised on day 7 and examined histologically. RESULTS: Normalized relative signal intensity of 70 Gy-irradiated right liver lobe (2.36 ± 0.22) and 50 Gy-irradiated right liver lobe (2.37 ± 0.46) was significantly lower than that of the non-irradiated right liver lobe (4.04 ± 0.28) on day 7, respectively (p < 0.05). Pearson product-moment correlation coefficient between relative intensity of the liver and the number of hepatic iron deposits was -0.588 (p < 0.01). CONCLUSION: Superparamagnetic iron oxide-enhanced MR imaging could demonstrate signal recovery delay in irradiated areas of rat livers. It seems that the signal recovery delay in irradiated areas was due to SPIO-derived iron deposition. Hepatic signal recovery could be a novel diagnostic marker for delineation of irradiated areas.


Assuntos
Meios de Contraste/farmacocinética , Dextranos/farmacocinética , Fígado/patologia , Fígado/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita , Animais , Relação Dose-Resposta à Radiação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/metabolismo , Masculino , Modelos Animais , Doses de Radiação , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med Sci ; 12(2): 95-103, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23666151

RESUMO

PURPOSE: Simultaneous magnetic resonance (MR) imaging of multiple small animals in a single session increases throughput of preclinical imaging experiments. Such imaging using a 3-tesla clinical scanner with multi-array coil requires correction of intensity variation caused by the inhomogeneous sensitivity profile of the coil. We explored a method for correcting intensity that we customized for multi-animal MR imaging, especially abdominal imaging. METHOD: Our institutional committee for animal experimentation approved the protocol. We acquired high resolution T1-, T2-, and T2*-weighted images and low resolution proton density-weighted images (PDWIs) of 4 rat abdomens simultaneously using a 3T clinical scanner and custom-made multi-array coil. For comparison, we also acquired T1-, T2-, and T2*-weighted volume coil images in the same rats in 4 separate sessions. We used software created in-house to correct intensity variation. We applied thresholding to the PDWIs to produce binary images that displayed only a signal-producing area, calculated multi-array coil sensitivity maps by dividing low-pass filtered PDWIs by low-pass filtered binary images pixel by pixel, and divided uncorrected T1-, T2-, or T2*-weighted images by those maps to obtain intensity-corrected images. We compared tissue contrast among the liver, spinal canal, and muscle between intensity-corrected multi-array coil images and volume coil images. RESULTS: Our intensity correction method performed well for all pulse sequences studied and corrected variation in original multi-array coil images without deteriorating the throughput of animal experiments. Tissue contrasts were comparable between intensity-corrected multi-array coil images and volume coil images. CONCLUSION: Our intensity correction method customized for multi-animal abdominal MR imaging using a 3T clinical scanner and dedicated multi-array coil could facilitate image interpretation.


Assuntos
Abdome/anatomia & histologia , Artefatos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/veterinária , Software , Algoritmos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
MAGMA ; 26(3): 313-24, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23117343

RESUMO

OBJECTIVE: Hepatic signal recovery, rather than reduction, in ferucarbotran-enhanced magnetic resonance imaging (MRI) is a potential diagnostic marker of liver damage. We investigated hepatic signal recovery in rats with gadolinium chloride (GdCl3)-induced Kupffer cell (KC) damage. MATERIALS AND METHODS: Twelve rats received 8 µmol iron/kg of ferucarbotran 1 day after 0-7.5 mg/kg GdCl3 injection (experiment A). Another 12 rats received ferucarbotran followed by GdCl3 injection 6 h later (experiment B). In each experiment, three rats without GdCl3 ("no injury group") served as control. Another six rats received GdCl3 alone without ferucarbotran. Hepatic signals were assessed on T 2 (*) -weighted images for up to 29 days. Iron deposits were histologically examined on day 29. RESULTS: Hepatic signal recovery was delayed in a GdCl3 dose-dependent manner in experiment A. Gadolinium chloride alone reduced hepatic signal 15 % during this experiment. Hepatic signal recovery was delayed only in rats that received 7.5 mg/kg GdCl3 in experiment B. Hepatic signals negatively correlated with iron deposits in KCs and hepatocytes. CONCLUSION: Hepatic signal recovery on ferucarbotran-enhanced MRI was delayed in the context of GdCl3-induced KC damage due to increased hepatic iron deposits. Hepatic signal recovery may be used as a clinical marker of KC damage in liver disorders, including radiation-induced hepatitis.


Assuntos
Doença Hepática Induzida por Substâncias e Drogas/etiologia , Doença Hepática Induzida por Substâncias e Drogas/patologia , Dextranos , Gadolínio/efeitos adversos , Células de Kupffer/efeitos dos fármacos , Células de Kupffer/patologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita , Animais , Meios de Contraste/efeitos adversos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/efeitos dos fármacos , Fígado/patologia , Masculino , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Magn Reson Imaging ; 38(1): 225-30, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23238830

RESUMO

PURPOSE: To explore simultaneous magnetic resonance imaging (MRI) for multiple hepatoma-bearing rats in a single session suppressing motion- and flow-related artifacts to conduct preclinical cancer research efficiently. MATERIALS AND METHODS: Our institutional Animal Experimental Committee approved this study. We acquired PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) T2 - and diffusion-weighted images of the liver in one healthy and 11 N1-S1 hepatoma-bearing rats in three sessions using a 3-T clinical scanner and dedicated multiarray coil. We compared tumor volumes on MR images and those on specimens, evaluated apparent diffusion coefficients (ADC) of the tumor, and compared them to previously reported values. RESULTS: Each MRI session took 39-50 minutes from anesthesia induction to the end of scans for four rats (10-13 minutes per rat). PROPELLER provided artifact-reduced T2 - and diffusion-weighted images of the rat livers. Tumor volumes on MR images ranged from 0.04-1.81 cm(3) and were highly correlated with those on specimens. The ADC was 1.57 ± 0.37 × 10(-3) mm(2) /s (average ± SD), comparable to previously reported values. CONCLUSION: PROPELLER allowed simultaneous acquisition of artifact-reduced T2 - and diffusion-weighted images of multiple hepatoma-bearing rats. This technique can promote high-throughput preclinical MR research for liver cancer.


Assuntos
Algoritmos , Artefatos , Carcinoma Hepatocelular/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Linhagem Celular Tumoral , Feminino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Magn Reson Med Sci ; 10(4): 229-37, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22214907

RESUMO

PURPOSE: Multiple small-animal magnetic resonance (MR) imaging to measure tumor volume may increase the throughput of preclinical cancer research assessing tumor response to novel therapies. We used a clinical scanner and multi-channel coil to evaluate the usefulness of this imaging to assess experimental tumor volume in mice. METHODS: We performed a phantom study to assess 2-dimensional (2D) geometric distortion using 9-cm spherical and 32-cell (8×4 one-cm(2) grids) phantoms using a 3-tesla clinical MR scanner and dedicated multi-channel coil composed of 16 5-cm circular coils. Employing the multi-channel coil, we simultaneously scanned 6 or 8 mice bearing sarcoma 180 tumors. We estimated tumor volume from the sum of the product of tumor area and slice thickness on 2D spin-echo images (repetition time/echo time, 3500/16 ms; in-plane resolution, 0.195×0.195×1 mm(3)). After MR acquisition, we excised and weighed tumors, calculated reference tumor volumes from actual tumor weight assuming a density of 1.05 g/cm(3), and assessed the correlation between the estimated and reference volumes using Pearson's test. RESULTS: Two-dimensional geometric distortion was acceptable below 5% in the 9-cm spherical phantom and in every cell in the 32-cell phantom. We scanned up to 8 mice simultaneously using the multi-channel coil and found 11 tumors larger than 0.1 g in 12 mice. Tumor volumes were 1.04±0.73 estimated by MR imaging and 1.04±0.80 cm(3) by reference volume (average±standard deviation) and highly correlated (correlation coefficient, 0.995; P<0.01, Pearson's test). CONCLUSION: Use of multiple small-animal MR imaging employing a clinical scanner and multi-channel coil enabled accurate assessment of experimental tumor volume in a large number of mice and may facilitate high throughput monitoring of tumor response to therapy in preclinical research.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Experimentais/patologia , Sarcoma/patologia , Carga Tumoral , Animais , Meios de Contraste , Modelos Animais de Doenças , Gadolínio , Compostos Heterocíclicos , Modelos Lineares , Imageamento por Ressonância Magnética/instrumentação , Camundongos , Compostos Organometálicos , Imagens de Fantasmas , Sensibilidade e Especificidade
19.
Radiographics ; 29(7): 1-22, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19734468

RESUMO

Hepatic transarterial interventional therapies such as chemoembolization and radiation embolization are important treatment options for hepatocellular carcinoma. Understanding the anatomy of individual arterial branches and hepatic segments is critical for selecting the correct embolization technique for treatment and to avoid complications. The authors describe the morphologic characteristics of hepatic arterial branches (and their mimickers) and hepatic segments on conventional angiograms. These vessels and segments include the celiac artery, the common and proper hepatic arteries, the left and right hepatic arteries and branches, the caudate lobe, and the portal vein and branches. Mimickers of hepatic arteries include the cystic, accessory left gastric, and right gastric arteries, as well as branches of the left gastric artery that resemble segmental branches of the replaced left hepatic artery. The authors describe how each segmental branch of the hepatic artery and the area it supplies correlates at computed tomography (CT) and angiography. Finally, the authors demonstrate how the vascular anatomy changes with the respiratory cycle by creating a virtual movie from calculations with dynamic CT data, in which the arterial and venous phases are acquired at end expiration and inspiration, respectively. Each segmental branch of the hepatic artery has morphologic characteristics that help distinguish it from mimickers. The location of each hepatic segment can be estimated if the artery supplying the segment can be correctly identified on angiograms. Notably, morphologic differences in the hepatic artery system caused by respiration should be recognized.


Assuntos
Angiografia/métodos , Artéria Hepática/anatomia & histologia , Artéria Hepática/diagnóstico por imagem , Modelos Anatômicos , Tomografia Computadorizada por Raios X/métodos , Humanos
20.
Jpn J Radiol ; 27(1): 41-4, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19373531

RESUMO

Posterior interosseous nerve palsy, also called deep radial nerve syndrome, is a neuropathy caused by radial nerve entrapment or compression at the level of the supinator muscle. Although imaging studies are not necessary for diagnosing this syndrome because of its characteristic clinical manifestations, the causes of palsy, which include mass lesions, or precise anatomical findings can sometimes be demonstrated by imaging. Magnetic resonance (MR) findings of posterior interosseous nerve palsy have been described as involving atrophy of related muscles caused by denervation, a common secondary change of this nerve disorder. We present a case in which the swollen posterior interosseous nerve itself could be directly depicted by MR imaging using a 4.7-cm microscopy coil in a patient with neuropathy.


Assuntos
Síndromes de Compressão Nervosa/patologia , Nervo Radial/patologia , Neuropatia Radial/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Microscopia , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Músculo Esquelético/patologia