Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 14(3): 5041-55, 2014 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-24618782

RESUMO

This study aimed to explore the application of infrared thermography in combination with ambulatory wearable monitoring of temperature and relative humidity, to assess the residual limb-to-liner interface in lower-limb prosthesis users. Five male traumatic transtibial amputees were involved, who reported no problems or discomfort while wearing the prosthesis. A thermal imaging camera was used to measure superficial thermal distribution maps of the stump. A wearable system for recording the temperature and relative humidity in up to four anatomical points was developed, tested in vitro and integrated with the measurement set. The parallel application of an infrared camera and wearable sensors provided complementary information. Four main Regions of Interest were identified on the stump (inferior patella, lateral/medial epicondyles, tibial tuberosity), with good inter-subject repeatability. An average increase of 20% in hot areas (P < 0.05) is shown after walking compared to resting conditions. The sensors inside the cuff did not provoke any discomfort during recordings and provide an inside of the thermal exchanges while walking and recording the temperature increase (a regime value is ~+1.1 ± 0.7 °C) and a more significant one (~+4.1 ± 2.3%) in humidity because of the sweat produced. This study has also begun the development of a reference data set for optimal socket/liner-stump construction.


Assuntos
Membros Artificiais , Telemetria/instrumentação , Termografia/instrumentação , Adulto , Calibragem , Humanos , Umidade , Processamento de Imagem Assistida por Computador , Masculino , Temperatura , Interface Usuário-Computador
2.
Stud Health Technol Inform ; 177: 203-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22942055

RESUMO

In the last decade, the trends in the development and management of healthcare services are focused on the personalization of prevention, diagnosis and treatment. This paper presents an example of the development of wearable technology for biosignal monitoring in the field of pre-term newborns care. The system was validated by an in-hospital pre-clinical test demonstrating efficiency, reliability and quality.


Assuntos
Eletrocardiografia Ambulatorial/instrumentação , Eletrodos , Recém-Nascido Prematuro , Terapia Intensiva Neonatal/métodos , Medicina de Precisão/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...