Magn Reson Imaging ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38547936

RESUMO

BACKGROUND: We devised a method that combines the 3D-Dixon-gradientecho (GRE) method with an improved motion-sensitized driven-equilibrium (iMSDE) to suppress blood flow signals. PURPOSE: The purpose of this study was to evaluate the effectiveness of the new method we developed plaque imaging method (3D-Dixon-GRE with the iMSDE method). STUDY TYPE: Retrospective cohort. POPULATION: Thirty-nine patients who underwent cervical plaque imaging. FIELD STRENGTH/SEQUENCE: 3.0 T/3D-GRE. ASSESSMENT: Signal intensities of the common carotid artery, aorta, plaque, muscle, and subcutaneous fat were measured through the VISTA and the 3D-Dixon-GRE with iMSDE methods, and each contrast was calculated. STATISTICAL TEST: Used the Mann Whitney U test. P-values below 0.05 were considered statistically significant. RESULTS: Plaque and muscle contrast estimated through the VISTA method and 3D-Dixon-GRE with iMSDE method was 1.60 ±â€¯0.96 and 2.04 ±â€¯1.06, respectively, (P < 0.05). The contrast between the flow (common carotid artery and Aorta) and muscle according to the VISTA method and 3D-Dixon-GRE with iMSDE method was 0.24 ±â€¯0.11 and 0.40 ±â€¯0.12, respectively (P < 0.001). Finally, the mean contrast for subcutaneous fat and muscle at six locations was 3.05 ±â€¯1.25 and 0.81 ±â€¯0.23 for the VISTA method and 3D-Dixon-GRE with the iMSDE method, respectively (P < 0.001). DATA CONCLUSION: Compared to the conventional method (VISTA), the 3D-Dixon-GRE with iMSDE method is preferable in relation to the fat suppression effect, but it is disadvantageous regarding blood flow signal suppression. Therefore, the 3D-Dixon-GRE with the iMSDE method could be considered useful for plaque imaging.

2.
J Appl Clin Med Phys ; 24(12): e14205, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37975638

RESUMO

In magnetic resonance imaging (MRI), it is necessary to reduce image distortion as much as possible because it suppresses the increase in the planning target volume. This study investigated the relationship between imaging parameters and image distortion when using G-frames. The images were obtained using a 1.5-T MRI system with a 09-101 Pro-MRI phantom. Image distortion was measured by changing the RF pulse mode, gradient mode, asymmetric echo, and bandwidth (BW). The image distortion was increased in the high RF mode than in the Normal mode. The image distortion increased in the following order: Whisper â‰¦ Normal < Fast in the different gradient modes. The image distortion increased in the following order: Without â‰¦ Weak < Strong in the different asymmetric echo modes. The image distortion increased in the following order: 300 Hz/pixel > 670 Hz/pixel â‰§ REF (150 Hz/pixel) in the different Bw. The relationship between parameters and image distortion was clarified in this study when G-frames were used for gamma knife therapy. There is had relationship between the parameters causing variation in the gradient magnetic field and image distortion. Therefore, these parameters should be adjusted to minimize distortion.


Assuntos
Imageamento por Ressonância Magnética , Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
3.
J Magn Reson ; 355: 107560, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37748233

RESUMO

This study aimed to investigate the effect of using slice partial Fourier (SPF), phase partial Fourier (PPF), and radial scan (Elliptical scanning) methods on image quality. Changes in signal-to-noise ratio (SNR), effective slice thickness, and in-plane resolution were measured in 3D-gradient echo when SPF, PPF, and radial scan were used. Effective slice thickness increased and SNR increased when SPF was used; in-plane resolution decreased and SNR decreased when PPF was used; effective slice thickness did not change, in-plane resolution decreased, and SNR increased when the radial scan method was used. The radial scan method reduces image quality and imaging time compared to those in the SPF and PPF methods.

4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(7): 682-692, 2023 Jul 20.
Artigo em Japonês | MEDLINE | ID: mdl-37316259

RESUMO

PURPOSE: To validate the point-A dose and dose distribution of metal and resin applicators in comparison with those of TG-43U1. METHODS: The metal and resin applicators consisting of tandem and ovoid were modeled by the egs_brachy. The doses to point A and dose distributions considering each applicator were calculated and compared to those of TG-43U1. RESULTS: The dose to point A considering the metal applicator was 3.2% lower than that of TG-43U1, but there was no difference in the dose to point A considering the resin applicator. The dose distribution considering the metal applicator was lower than that of TG-43U1 at all calculation points, but there was no difference in the dose distribution considering the resin applicator at almost all calculation points. CONCLUSION: In this study, the dose distribution considering the metal applicator was lower than that of TG-43U1 at all calculation points, but there was no difference in the dose distribution considering the resin applicator at almost all calculation points. Therefore, TG-43U1 can accurately calculate the dose distribution when changing from the metal applicator to the resin applicator.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Dosagem Radioterapêutica , Metais , Imagens de Fantasmas , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Radiometria
5.
Rev Sci Instrum ; 93(6): 064101, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778036

RESUMO

This paper proposes a new concept of phantom development, along with the utilization of new materials that can reproduce lung morphology and density. A lung substitute phantom using microspheres was fabricated; then, its dosimetric utility in radiotherapy was investigated, during which the density was adjusted to closely resemble the morphology of the actual human lung. Microspheres were used to reproduce alveoli, which are the main components of the lung. By changing the ratio of urethane, which is commonly used in soft tissue phantoms, to microspheres, we reproduced the density change of the lungs due to respiration. Here, we fabricated two slab-like lung substitutes to emulate commercially used phantoms. Although there is room for improvement in terms of practicality, the substitutes were easy to fabricate. Microscopic observation of the cut surface of the phantoms showed that the morphology of the phantoms mimicked the alveoli more faithfully than commercial phantoms. Furthermore, to compensate for the energy-independent mass attenuation and mass collision inhibition ability required by the tissue substitute phantom, we examined the physical properties of the phantom and confirmed that there was negligible energy dependence.


Assuntos
Pulmão , Radiometria , Humanos , Microesferas , Imagens de Fantasmas , Fenômenos Físicos
6.
Appl Radiat Isot ; 186: 110301, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35617893

RESUMO

In this study, we developed a mouthpiece-type gel dosimeter to prevent the oral mucositis caused by the perturbation effect of dental alloys in the radiotherapy of the head and neck regions and to enable in vivo dosimetry. Understanding the dose distribution in the oral cavity during radiotherapy helps identify the possible site for oral mucositis during treatment. Here agarose, which has a higher melting point than gelatin, was added as a coagulant to stabilize the shape of the dosimeter. The strength and dose response of the dosimeter were investigated. The strength was measured at room temperature, 20°C-40 °C, which is higher than the intraoral temperature. The dose-response curves were obtained by magnetic resonance imaging with R2 ranging from 0 to 25 Gy. The strength and dose response of the mouthpiece-type gel dosimeter were approximately 4 and 2.1 times higher than those of polyacrylamide gel and tetrakis hydroxymethyl phosphonium chloride dosimeters commonly used in the prescribed doses per fraction of treatment. The dosimeter is composed of 4 wt% MgCl2 and 1.5 wt% agarose; thus, it can retain the water equivalence. Through in vivo oral dosimetry in three dimensions for head and neck radiotherapy with dental alloys using the mouthpiece-type gel dosimeter, we obtained three-dimensional dose distributions in the dosimeter. The properties of the dosimeter show that it can be used in the clinic, depending on the prescribed dose.


Assuntos
Dosimetria in Vivo , Estomatite , Ligas Dentárias , Géis , Humanos , Polímeros , Dosímetros de Radiação , Radiometria/métodos , Sefarose
7.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(5): 473-483, 2022 May 20.
Artigo em Japonês | MEDLINE | ID: mdl-35342124

RESUMO

PURPOSE: The incident electron energy spectrum was determined by an estimation formula based on the Lévy distribution in order to calculate the PDD and OAR that is consistent with the measurement. METHODS: EGSnrc was used to calculate PDD and OAR at nominal energies of 4, 6, 9, 12, and 15 MeV. The parameters for determining the incident electron energy spectrum were adjusted to be a reasonable value in the error between the measured and the calculated values. RESULTS: Location and scaling parameters were determined to be 0.5 and 0.001, respectively. The calculated PDD based on the determination formula was in agreement with the measurement within 2 mm/2% at all depths. The OAR also was in agreement with the measurement within 2 mm/2%. CONCLUSION: In this study, the incident electron energy spectrum was estimated by determining the location and scaling parameters. This method is simpler and more accurate than previously reported, and can be applied to the calculation of dose distributions in Monte Carlo simulations.


Assuntos
Elétrons , Planejamento da Radioterapia Assistida por Computador , Simulação por Computador , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
8.
Jpn J Radiol ; 40(3): 318-325, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34655387

RESUMO

Real-time tumor tracking radiotherapy (RTRT) systems typically use fiducial markers implanted near the tumor to track the target using X-ray fluoroscopy. Template pattern matching, used in tracking, is often used to automatically localize the fiducial markers. In radiotherapy of the liver, the thickness of the body that can recognize the fiducial markers must be clinically assessed. The purpose of this study was to quantify the recognition of fiducial markers according to body thickness in stereotactic body radiotherapy of the liver using clinical images obtained using SyncTraX FX4. The recognition scores of fiducial markers were examined in relation to water equivalent length (WEL), tube current, and each flat panel detector. The relationship between the contrast ratio of the fiducial marker and the background and the WEL was also investigated. The average recognition score was found to be less than 20 when the WEL was greater than 25 cm. The probability of successful tracking of image recognition was mostly smaller than 0.8 when the WEL was over 30 cm. The relationship between WEL and tube current did not significantly differ between 100 and 140 mA, but there was a significant difference (p < 0.05) for all other combinations. To ensure tracking of fiducial markers during SBRT, if the WEL representing body thickness is longer than 25 cm, the X-ray fluoroscopy arrangement should be determined based on the WEL.


Assuntos
Neoplasias , Radiocirurgia , Marcadores Fiduciais , Humanos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Água
9.
J Radiat Res ; 63(1): 137-147, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-34718704

RESUMO

This study aimed to quantitatively clarify the baseline drift for each respiratory cycle in two respiratory-gating methods using the intra-beam respiratory motion data of lung cancer patients. The residual motion and dose distribution were calculated based on intra-beam respiratory motion data with the baseline drift. To quantify the baseline drift $\Delta$ during irradiation, it was defined as the inclination between the detected expiration point and the expiration point in the next cycle in the anterior-posterior (AP), cranial-caudal (CC) and left-right (LR) directions obtained using an in-house programme. The baseline drift value reached up to 0.74 mm/s in the CC direction as per the respiratory motion data of 10 patients. The homogeneity index (HI) of the phase-gating method tended to increase because the target was irradiated even when the amplitude position of the target differed from period to period. In contrast, the amplitude-gating method enabled irradiation considering the amplitude position of the target because the gating window was set considering the amplitude position of the respiratory motion. The respiratory-gating methods and respiratory phase in respiratory-gating lung stereotactic body radiation therapy (SBRT) must be determined based on the respiratory motion of the patients.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Movimento (Física) , Movimento , Radiocirurgia/métodos
10.
J Radiat Res ; 62(5): 841-845, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34401925

RESUMO

Temperature corrections are necessary to account for the varying mass of air in the cavity volume of a vented ionization chamber. The temporal response resulting from temperature changes in a cylindrical and/or Farmer-type ionization chamber, which is the standard dosimeter, has been thoroughly discussed by some researchers. The purpose of this study was to characterise and analyse the dependence of the cavity air temperature of the parallel-plate-type ionization chamber on changes in the ambient temperature. Ionization chambers NACP-02 (IBA Dosimetry, GmbH) and Advanced Markus TN34045 (PTW, Freiburg) were modelled using thermal analysis software to present the temperature equilibrium time and the entire ionization chamber temperature distribution. The temporal response of each ionization chamber was measured for comparing the calculation results of the thermal analysis. The ionization chamber cavities of NACP-02 and TN34045 reached complete equilibrium in 670 and 750 s, respectively. Heat transfer occurred faster at the centre of the front wall of TN34045 than at the outside of the centre except for the edges. Further, the non-uniformity of temperature in the cavity was in the range of 24.2-24.8°C for NACP-02 and 23.7-24.4°C for TN34045 at 200 s after the ionization chamber was installed in the water phantom. The previous proposal to wait for about 15 mins after submerging the chamber in a water phantom before the measurement is demonstrated to be appropriate for parallel-plate-type ionization chambers.


Assuntos
Radiometria/instrumentação , Temperatura , Simulação por Computador , Desenho de Equipamento , Modelos Teóricos , Imagens de Fantasmas , Fatores de Tempo
12.
J Radiat Res ; 61(5): 712-717, 2020 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-32657342

RESUMO

In this study, we propose a methodology for temperature determination of the temperature and pressure correction factor, PTP, by analyzing the temperature distribution of the modeled ionization chamber taking into account the thermal effect of a water phantom on neighboring materials in the process. Additionally, we present an appropriate temperature-equilibrium time for conducting measurements. The temporal response in the cavity is acquired at 20-s intervals using a Farmer ionization chamber and an electrometer. The initial temperature of the water phantom is 20-25°C with continuous heating/cooling. The temporal response is measured until temperature equilibrium is confirmed, specifically when a temperature difference of 1-5°C is observed between the ionization chamber and the water phantom. Using an ionization-chamber model, temperature distribution is simulated between 20 and 25°C with various parameters set to receive heating and cooling from surrounding media. The results suggest that the temporal response of the ionization chamber essentially coincides with the temperature change at the tip and middle; moreover, the predicted temperature change for temporal response and the simulated temperature of water are different by ~0.16°C at the tip and ~0.79°C at the bottom. Overall, the temperature-equilibration time for absorbed dosimetry is affected by two factors: the cavity wall and the stem side of the cavity; moreover, 400 s is required to obtain complete temperature equilibrium in the water phantom. This analytical study supports the experimental value obtained in previous research. Therefore, analytical representation of the temperature distribution in the ionization chamber is possible.


Assuntos
Temperatura , Condutividade Térmica , Fatores de Tempo , Água
13.
Appl Radiat Isot ; 151: 62-66, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31158707

RESUMO

Herein, we investigate the use of agar and gelatin in a polymer gel dosimeter. The polymer gel is enclosed in a vinyl film to obtain a dosimeter of arbitrary shape and maintain the shape at room temperature. The resulting polymer gel dosimeter could preserve its shape across a wide temperature range. Excluding the surface region, the obtained dose distribution was within 3% of that determined in an ionization chamber.


Assuntos
Ágar , Polímeros , Dosímetros de Radiação , Géis
14.
Rev Sci Instrum ; 86(9): 096103, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26429490

RESUMO

Tangential beam radiotherapy is routinely used for radiation therapy after breast conserving surgery. A tissue-equivalent bolus placed on the irradiated area shifts the depth of the dose distribution; this bolus provides uniform dose distribution to the breast. The gel bolus made by the BANG-Pro(®) polymer gel and in an oxygen non-transmission pack was applicable as a dosimeter to measure dose distribution in near-surface buildup region. We validated the use of the gel bolus to improve in the whole-breast/chest wall, including the near-surface buildup region.


Assuntos
Neoplasias da Mama/radioterapia , Polímeros/química , Radiometria/instrumentação , Géis , Método de Monte Carlo
15.
Igaku Butsuri ; 33(4): 166-70, 2013.
Artigo em Japonês | MEDLINE | ID: mdl-24893491

RESUMO

In this study, we developed an isocenter verification device for use in proton therapy. Radiation and mechanical isocenters were verified for treatment equipment including room lasers, a digital radiography system and the beam axis of a rotational gantry. The special feature of this device is its ability to correlate the position of the three isocenters in one measurement and thus improve accuracy compared to the conventional method using three separate devices. The reproducibility of the method and the fluctuation of the position of the beam axis isocenter were both investigated using this device for almost a year. Monthly measurements of the isocenter position were acquired for two gantries and it was found that the fluctuation was +/- 0.10mm for the up-to-down direction and +/- 0.16mm for the right-to-left direction in Gantry 1 and was +/-0.14mm for the up-to-down direction and +/-0.18mm for the right-to-left direction in Gantry 2. We could be measured with a repeatability of +/-0.18 mm or less by using developed device for the relative positional relationship between each isocenters. Because we can confirm results in approximately 30 minutes, we can perform a quality control after a clinical practice.


Assuntos
Prótons , Radioterapia Assistida por Computador/instrumentação , Imagens de Fantasmas , Controle de Qualidade , Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Reprodutibilidade dos Testes
16.
Phys Med ; 29(4): 388-96, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22771332

RESUMO

External electron radiotherapy is performed using a cone or applicator to collimate the beam. However, because of a trade-off between collimation and scattering/bremsstrahlung X-ray production, applicators generate a small amount of secondary radiation (leakage). We investigate the peripheral dose outside the radiation field of a Varian-type applicator. The dose and fluence outside the radiation field were analyzed in a detailed Monte Carlo simulation. The differences between the calculation results and data measured in a water phantom in an ionization chamber were less than ±1% in regions more than 3 mm below the surface of the phantom and at the depth of dose maximum. The calculated fluence was analyzed inside and outside the radiation field on a plane just above the water phantom surface. Changing the electron energy affected the off-axis fluence distribution outside the radiation field; however, the size of the applicator had little effect on this distribution. For each energy, the distributions outside the radiation field were similar to the dose distribution at shallow depths in the water phantom. The effect of secondary electrons generation by photon transmission through the alloy making up the lowest scraper was largest in the region from the field edge to directly below the cutout and at higher beam energies. The results of the Monte Carlo simulation confirm that the peripheral dose outside the field is significantly affected by radiation scattered or transmitted from the applicator, and the effect increases with the electron energy.


Assuntos
Elétrons/uso terapêutico , Método de Monte Carlo , Imagens de Fantasmas , Radioterapia Assistida por Computador/instrumentação , Espalhamento de Radiação , Aceleradores de Partículas , Dosagem Radioterapêutica , Água
17.
Artigo em Japonês | MEDLINE | ID: mdl-22026984

RESUMO

It is stated that cardiac MRI imaging can provide accurate estimation of left ventricular (LV) volumes and ejection fraction (EF). The purpose of this study was to evaluate the accuracy of gated myocardial perfusion SPECT for assessment of LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF, using cardiac MRI as the reference methods/(methodology). Gated myocardial perfusion SPECT images were analyzed with two different quantification software, QGS and 4D-MSPECT. Thirty-four consecutive patients were studied. Myocardial perfusion SPECT and cardiac MRI had excellent intra/interobserver reproducibility. Correlation between the results of gated myocardial perfusion SPECT and cardiac MRI were high for EDV and EF. However, ESV and EDV were significantly underestimated by gated myocardial perfusion SPECT compared to cardiac MRI. Moreover, gated myocardial perfusion SPECT overestimated EF for small heart. One reason for the difference in volumes and EF is the delineation of the endocardial border. Cardiac MRI has higher spatial resolution. We should understand the differences of volumes and EF as determined by gated myocardial perfusion SPECT and cardiac MRI.


Assuntos
Volume Cardíaco , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Volume Sistólico , Função Ventricular Esquerda , Idoso , Diástole , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Software , Sístole
18.
Artigo em Japonês | MEDLINE | ID: mdl-21666375

RESUMO

UNLABELLED: The purpose of this study was to evaluate the effect of myocardial perfusion imaging that is reconstructed using the ordered subsets-expectation maximization (OS-EM) method with collimator broad correction. METHODS: A cardiac phantom and clinical data (with ten normal patients) were used. These projection data were reconstructed using OS-EM with collimator broad correction (OS-EM(+)), without collimator broad correction (OS-EM(-)), and with filtered back projection (FBP). We analyzed the reconstructed images using the following: FWHM of reoriented short-axis data, volume calculated using QGS software, and a polar map calculated using QPS software. RESULTS AND CONCLUSION: On the important point of spatial resolution, OS-EM(+) was excellent compared with FBP. However, a difference in % uptake was seen in one segment. Therefore, when a quantitative myocardial SPECT evaluation is done, the treatment of the numerical value needs to be noted.


Assuntos