Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Respir Physiol Neurobiol ; 325: 104264, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38599345

RESUMO

Eight pig tracheal strips were stimulated to contract with log increments of methacholine from 10-8 to 10-5 M. For each strip, the concentration-response was repeated four times in a randomized order to measure isometric force, isotonic shortening against a load corresponding to either 5 or 10 % of a reference force, and average force, stiffness, elastance and resistance over one cycle while the strip length was oscillating sinusoidally by 5 % at 0.2 Hz. For each readout, the logEC50 was calculated and compared. Isotonic shortening with a 5 % load had the lowest logEC50 (-7.13), yielding a greater sensitivity than any other contractile readout (p<0.05). It was followed by isotonic shortening with a 10 % load (-6.66), elastance (-6.46), stiffness (-6.46), resistance (-6.38), isometric force (-6.32), and average force (-6.30). Some of these differences were significant. For example, the EC50 with the average force was 44 % greater than with the elastance (p=0.001). The methacholine sensitivity is thus affected by the contractile readout being measured.


Assuntos
Broncoconstritores , Cloreto de Metacolina , Músculo Liso , Traqueia , Animais , Músculo Liso/fisiologia , Músculo Liso/efeitos dos fármacos , Cloreto de Metacolina/farmacologia , Suínos , Traqueia/fisiologia , Traqueia/efeitos dos fármacos , Broncoconstritores/farmacologia , Contração Muscular/fisiologia , Contração Muscular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Elasticidade/fisiologia , Contração Isométrica/fisiologia , Contração Isométrica/efeitos dos fármacos
2.
Sci Rep ; 13(1): 17481, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838793

RESUMO

This study was undertaken to determine whether a smaller lung volume or a stiffer lung tissue accounts for the greater lung elastance of C57BL/6 than BALB/c mice. The mechanical properties of the respiratory system and lung volumes were measured with the flexiVent and compared between male C57BL/6 and BALB/c mice (n = 9). The size of the excised lung was also measured by volume liquid displacement. One lobe was then subjected to sinusoidal strains in vitro to directly assess the mechanical properties of the lung tissue, and another one was used to quantify the content of hydroxyproline. In vivo elastance was markedly greater in C57BL/6 than BALB/c mice based on 5 different readouts. For example, respiratory system elastance was 24.5 ± 1.7 vs. 21.5 ± 2.4 cmH2O/mL in C57BL/6 and BALB/c mice, respectively (p = 0.007). This was not due to a different lung volume measured by displaced liquid volume. On the isolated lobes, both elastance and the hydroxyproline content were significantly greater in C57BL/6 than BALB/c mice. These results suggest that the lung elastance of C57BL/6 mice is greater than BALB/c mice not because of a smaller lung volume but because of a stiffer lung tissue due to a greater content of collagen.


Assuntos
Pulmão , Camundongos , Animais , Masculino , Camundongos Endogâmicos BALB C , Hidroxiprolina , Camundongos Endogâmicos C57BL , Complacência Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...