Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Turk J Phys Med Rehabil ; 63(4): 340-347, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31453477

RESUMO

OBJECTIVES: The aim of this study was to investigate the effectiveness of walking with Equipment for Clever Exercise (ECE PEDO) compared to supervised, moderate-intensity, aerobic, treadmill walking exercise in overweight and obese women. PATIENTS AND METHODS: Between September 2014 and January 2015, 28 women with overweight and obesity were assigned to two groups: supervised treadmill walking (Group 1, n=14) or walking with ECE PEDO (Group 2, n=14). The target heart rate (HR) corresponding to values of 50 to 70% VO2max were determined by submaximal treadmill test. Group 1 was instructed walking at their target HR on treadmill. The number of steps in a min corresponding to the target HR was calculated by a criterion pedometer and Group 2 was instructed walking in this step range recorded to the ECE PEDO giving audible feedback. Before and after a 12-week exercise program, all participants were evaluated by Body Mass Index (BMI) and waist circumference (WC). Ultrasonographic visceral fat thickness (VFT) and ergospirometric VO2max. RESULTS: The VFT decreased in both walking groups in association with reduced WC and weight loss and also significant increases in the VO2max after exercise intervention (p<0.05). The VFT decreased only in women by walking with ECE PEDO compared to the other group (p<0.05). CONCLUSION: Our study results showed that both moderate-intensity exercise provided by a novel pedometer and supervised treadmill walking showed significant improvements in abdominal obesity and VO2max.

2.
Medicine (Baltimore) ; 95(10): e3025, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26962822

RESUMO

The purpose of this study was to examine the monitoring capabilities of the equipment for clever exercise pedometer (ECE PEDO) that provides audible feedback when the person exceeds the upper and lower limits of the target step numbers per minute and to compare step counts with Yamax SW-200 (YX200) as the criterion pedometer.A total of 30 adult volunteers (15 males and 15 females) were classified as normal weight (n = 10), overweight (n = 10), and obese (n = 10). After the submaximal exercise test on a treadmill, the moderate intensity for walking was determined by using YX200 pedometer and then the number of steps taken in a minute was measured. Lower and upper limits of steps per minute (cadence) were recorded in ECE PEDO providing audible feedback when the person's walking speed gets out of the limits. Volunteers walked for 30 minutes in the individual step count range by attaching the ECE PEDO and YX200 pedometer on both sides of the waist belt in the same session. Step counts of the volunteers were recorded. Wilcoxon, Spearman correlation, and Bland-Altman analyses were performed to show the relationship and agreement between the results of 2 devices.Subjects took an average of 3511 ±â€Š426 and 3493 ±â€Š399 steps during 30 minutes with ECE PEDO and criterion pedometer, respectively. About 3500 steps taken by ECE PEDO reflected that this pedometer has capability of identifying steps per minute to meet moderate intensity of physical activity. There was a strong correlation between step counts of both devices (P < 0.001, r = 0.96). Correlations across all three BMI categories and both sex remained consistently high ranging from 0.92 to 0.95. There was a high level of agreement between the ECE PEDO and YX200 pedometer in the Bland-Altman analysis.Although both devices showed a strong similarity in counting steps, the ECE PEDO provides monitoring of intensity such that a person can walk in a specified time with a desired speed.


Assuntos
Retroalimentação , Monitorização Ambulatorial/instrumentação , Atividade Motora/fisiologia , Obesidade/fisiopatologia , Sobrepeso/fisiopatologia , Caminhada/fisiologia , Adulto , Composição Corporal , Desenho de Equipamento , Teste de Esforço , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...