Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; : e2401467, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884161

RESUMO

Studying brain-wide hemodynamic responses to different stimuli at high spatiotemporal resolutions can help gain new insights into the mechanisms of neuro- diseases and -disorders. Nonetheless, this task is challenging, primarily due to the complexity of neurovascular coupling, which encompasses interdependent hemodynamic parameters including cerebral blood volume (CBV), cerebral blood flow (CBF), and cerebral oxygen saturation (SO2). The current brain imaging technologies exhibit inherent limitations in resolution, sensitivity, and imaging depth, restricting their capacity to comprehensively capture the intricacies of cerebral functions. To address this, a multimodal functional ultrasound and photoacoustic (fUSPA) imaging platform is reported, which integrates ultrafast ultrasound and multispectral photoacoustic imaging methods in a compact head-mountable device, to quantitatively map individual dynamics of CBV, CBF, and SO2 as well as contrast agent enhanced brain imaging at high spatiotemporal resolutions. Following systematic characterization, the fUSPA system is applied to study brain-wide cerebrovascular reactivity (CVR) at single-vessel resolution via relative changes in CBV, CBF, and SO2 in response to hypercapnia stimulation. These results show that cortical veins and arteries exhibit differences in CVR in the stimulated state and consistent anti-correlation in CBV oscillations during the resting state, demonstrating the multiparametric fUSPA system's unique capabilities in investigating complex mechanisms of brain functions.

2.
J Biophotonics ; : e202400058, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695390

RESUMO

Vascular diseases are a leading cause of death and disability worldwide. Despite having precursor conditions like peripheral arterial disease (PAD), they are often only diagnosed after the onset of stroke or heart attack. Low-cost, portable, noninvasive, point-of-care (POC), label-free assessment of deep vascular function benefits PAD diagnosis, especially in resource poor settings of the world. Doppler ultrasound-based blood flow measurements can diagnose PAD, albeit with limited sensitivity and specificity. To overcome this, here, we propose the first-of-its-kind dual-modality photoacoustic-and-ultrasound (PAUS) imaging system that integrates a multiwavelength pulsed laser diode (PLD) with a compact ultrasound data acquisition unit. The mesoscopic imaging depth of the portable PLD-PAUS system was validated using tissue phantoms, and its multispectral photoacoustic imaging capabilities were validated using an atherosclerosis-mimicking phantom. Furthermore, we demonstrated high-contrast volumetric in vivo photoacoustic imaging of rodent abdominal vasculature and quantified vessel reactivity due to hypercapnia stimulation. The multiparametric functional and molecular imaging capabilities of the PLD-PAUS system holds promise for POC applications.

3.
IEEE Sens J ; 24(4): 4380-4386, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38505656

RESUMO

Photoacoustic (PA) imaging provides deep tissue molecular imaging of chromophores with optical absorption contrast and ultrasonic resolution. Present PA imaging techniques are predominantly limited to one 2D plane per acquisition. 2D ultrasound transducers, required for real-time 3D PA imaging, are high-cost, complex to fabricate and have limited scalability in design. We present novel PCB-based 2D matrix ultrasound transducer arrays that are capable of being bulk manufactured at low-cost without using laborious ultrasound fabrication tools. The 2D ultrasound array specifications are easily scalable with respect to widely available PCB design and fabrication tools at low cost. To demonstrate scalability, we fabricated low (11 MHz) frequency 8x8 matrix array and high (40 MHz) frequency 4x4 matrix array by directly bonding an undiced polyvinylidene fluoride (PVDF) piezoelectric material of desired thickness to the custom designed PCB substrate. Characterization results demonstrate wideband PA receive sensitivity for both low (87%) and high (188%) frequency arrays. Volumetric PA imaging results of light absorbing targets inside optical scattering medium demonstrate improved spatial resolution and field of view with increase in aperture size.

4.
bioRxiv ; 2023 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37986863

RESUMO

Understanding brain-wide hemodynamic responses to different stimuli at high spatiotemporal resolutions can help study neuro-disorders and brain functions. However, the existing brain imaging technologies have limited resolution, sensitivity, imaging depth and provide information about only one or two hemodynamic parameters. To address this, we propose a multimodal functional ultrasound and photoacoustic (fUSPA) imaging platform, which integrates ultrafast ultrasound and multispectral photoacoustic imaging methods in a compact head-mountable device, to quantitatively map cerebral blood volume (CBV), cerebral blood flow (CBF), oxygen saturation (SO2) dynamics as well as contrast agent enhanced brain imaging with high spatiotemporal resolutions. After systematic characterization, the fUSPA system was applied to quantitatively study the changes in brain hemodynamics and vascular reactivity at single vessel resolution in response to hypercapnia stimulation. Our results show an overall increase in brain-wide CBV, CBF, and SO2, but regional differences in singular cortical veins and arteries and a reproducible anti-correlation pattern between venous and cortical hemodynamics, demonstrating the capabilities of the fUSPA system for providing multiparametric cerebrovascular information at high-resolution and sensitivity, that can bring insights into the complex mechanisms of neurodiseases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...