Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Virol J ; 21(1): 99, 2024 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-38685117

RESUMO

BACKGROUND: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.


Assuntos
Antígenos Virais , Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/imunologia , Teste Sorológico para COVID-19/métodos , Antígenos Virais/imunologia , Antígenos Virais/análise , Teste para COVID-19/métodos
2.
Sci Rep ; 13(1): 21913, 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081881

RESUMO

Self-testing is an effective tool to bridge the testing gap for several infectious diseases; however, its performance in detecting SARS-CoV-2 using antigen-detection rapid diagnostic tests (Ag-RDTs) has not been systematically reviewed. This study aimed to inform WHO guidelines by evaluating the accuracy of COVID-19 self-testing and self-sampling coupled with professional Ag-RDT conduct and interpretation. Articles on this topic were searched until November 7th, 2022. Concordance between self-testing/self-sampling and fully professional-use Ag-RDTs was assessed using Cohen's kappa. Bivariate meta-analysis yielded pooled performance estimates. Quality and certainty of evidence were evaluated using QUADAS-2 and GRADE tools. Among 43 studies included, twelve reported on self-testing, and 31 assessed self-sampling only. Around 49.6% showed low risk of bias. Overall concordance with professional-use Ag-RDTs was high (kappa 0.91 [95% confidence interval (CI) 0.88-0.94]). Comparing self-testing/self-sampling to molecular testing, the pooled sensitivity and specificity were 70.5% (95% CI 64.3-76.0) and 99.4% (95% CI 99.1-99.6), respectively. Higher sensitivity (i.e., 93.6% [95% CI 90.4-96.8] for Ct < 25) was estimated in subgroups with higher viral loads using Ct values as a proxy. Despite high heterogeneity among studies, COVID-19 self-testing/self-sampling exhibits high concordance with professional-use Ag-RDTs. This suggests that self-testing/self-sampling can be offered as part of COVID-19 testing strategies.Trial registration: PROSPERO: CRD42021250706.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Testes de Diagnóstico Rápido , Autoteste , Sensibilidade e Especificidade
3.
Nat Cancer ; 4(1): 96-107, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36581734

RESUMO

Patients with cancer are at high risk of severe coronavirus disease 2019 (COVID-19), with high morbidity and mortality. Furthermore, impaired humoral response renders severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines less effective and treatment options are scarce. Randomized trials using convalescent plasma are missing for high-risk patients. Here, we performed a randomized, open-label, multicenter trial ( https://www.clinicaltrialsregister.eu/ctr-search/trial/2020-001632-10/DE ) in hospitalized patients with severe COVID-19 (n = 134) within four risk groups ((1) cancer (n = 56); (2) immunosuppression (n = 16); (3) laboratory-based risk factors (n = 36); and (4) advanced age (n = 26)) randomized to standard of care (control arm) or standard of care plus convalescent/vaccinated anti-SARS-CoV-2 plasma (plasma arm). No serious adverse events were observed related to the plasma treatment. Clinical improvement as the primary outcome was assessed using a seven-point ordinal scale. Secondary outcomes were time to discharge and overall survival. For the four groups combined, those receiving plasma did not improve clinically compared with those in the control arm (hazard ratio (HR) = 1.29; P = 0.205). However, patients with cancer experienced a shortened median time to improvement (HR = 2.50; P = 0.003) and superior survival with plasma treatment versus the control arm (HR = 0.28; P = 0.042). Neutralizing antibody activity increased in the plasma cohort but not in the control cohort of patients with cancer (P = 0.001). Taken together, convalescent/vaccinated plasma may improve COVID-19 outcomes in patients with cancer who are unable to intrinsically generate an adequate immune response.


Assuntos
COVID-19 , Neoplasias , Humanos , COVID-19/terapia , SARS-CoV-2 , Imunização Passiva/efeitos adversos , Resultado do Tratamento , Soroterapia para COVID-19 , Anticorpos Antivirais , Neoplasias/terapia
4.
Microbiol Spectr ; 10(5): e0122922, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36066256

RESUMO

Access to reverse transcription-PCR (RT-PCR) testing, the gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection, is limited throughout the world, due to restricted resources, available infrastructure, and high costs. Antigen-detecting rapid diagnostic tests (Ag-RDTs) overcome some of these barriers, but independent clinical validations in settings of intended use are scarce. To inform the World Health Organization's (WHO) emergency use listing (EUL) procedure and ensure affordable, high-quality Ag-RDTs, we assessed the performance and ease of use of the SureStatus for SARS-CoV-2. For this prospective, multicenter diagnostic accuracy study, we recruited unvaccinated participants with presumed SARS-CoV-2 infection in India and Germany from December 2020 to March 2021, when the Alpha (B.1.1.7) variant was predominantly circulating. Paired swabs were performed for (i) routine clinical RT-PCR testing (sampling was either nasopharyngeal [NP] or combined NP and oropharyngeal [NP/OP]) and (ii) Ag-RDT (sampling was NP). Performance of the Ag-RDT was compared to RT-PCR overall and by predefined subgroups, e.g., cycle threshold (CT) value, symptoms, and days from symptom onset. To understand the usability, a system usability scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. A total of 1,119 participants were included in the analysis, of whom 205 (18.3%) were RT-PCR positive. SureStatus detected 169 out of 205 RT-PCR-positive participants, reporting a sensitivity of 82.4% (95% confidence interval [CI]: 76.6% to 87.1%) and a specificity of 98.5% (95% CI: 97.4% to 99.1%). In the first 7 days post-symptom onset, the sensitivity was 90.7% (95% CI: 83.5% to 94.9%), when CT values were low and viral loads were high. The test was characterized as easy to use (SUS, 85/100) and considered suitable for point-of-care settings, although quality concerns were raised due to visibly contaminated packaging of swabs included in the test kits. The SureStatus diagnostic test can be considered a reliable test during the first week of SARS-CoV-2 infection, with high sensitivity in combination with excellent usability. IMPORTANCE Our manufacturer-independent, prospective diagnostic accuracy study assessed clinical performance in participants presumed to have a SARS-CoV-2 infection at three study sites in two countries. We assessed the accuracy overall and in predefined subgroups (CT values and symptom duration). SureStatus performed with high sensitivity. Its sensitivity was particularly high in the first 3 days after symptom onset and when CT values were low (i.e., the viral load was high). The system usability and ease-of-use assessment complements the accuracy assessment of the test and highlights critical factors to facilitate the widespread use of SureStatus in point-of-care settings. The high sensitivity demonstrated by the evaluated Ag-RDT within the first days of symptoms, when most transmission occurs, supports the role of Ag-RDTs for public health-relevant screening. Evidence from this study was used to inform the World Health Organization Emergency Use Listing procedure.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Testes Diagnósticos de Rotina , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Organização Mundial da Saúde
5.
PLoS Med ; 19(5): e1004011, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35617375

RESUMO

BACKGROUND: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and <25, compared to 54.4% [95% CI 47.3 to 61.5] and 18.7% [95% CI 13.9 to 23.4] for Ct-values ≥25 and ≥30) and was estimated to increase by 2.9 percentage points (95% CI 1.7 to 4.0) for every unit decrease in mean Ct-value when adjusting for testing procedure and patients' symptom status. Concordantly, we found the mean Ct-value to be lower for true positive (22.2 [95% CI 21.5 to 22.8]) compared to false negative (30.4 [95% CI 29.7 to 31.1]) results. Testing in the first week from symptom onset resulted in substantially higher sensitivity (81.9% [95% CI 77.7 to 85.5]) compared to testing after 1 week (51.8%, 95% CI 41.5 to 61.9). Similarly, sensitivity was higher in symptomatic (76.2% [95% CI 73.3 to 78.9]) compared to asymptomatic (56.8% [95% CI 50.9 to 62.4]) persons. However, both effects were mainly driven by the Ct-value of the sample. With regards to sample type, highest sensitivity was found for nasopharyngeal (NP) and combined NP/oropharyngeal samples (70.8% [95% CI 68.3 to 73.2]), as well as in anterior nasal/mid-turbinate samples (77.3% [95% CI 73.0 to 81.0]). Our analysis was limited by the included studies' heterogeneity in viral load assessment and sample origination. CONCLUSIONS: Ag-RDTs detect most of the individuals infected with SARS-CoV-2, and almost all (>90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
7.
Infection ; 50(2): 395-406, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34383260

RESUMO

PURPOSE: Rapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity (≤ 85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. METHODS: This multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx™ assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. RESULTS: The study was conducted between November 2nd 2020 and 4th of December 2020. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx™, resulting in a sensitivity of 82.2% (95% CI 75.2-87.5%). Specificity was 99.3% (CI 98.3-99.7%). Sensitivity was increased in individuals with viral load ≥ 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI 86.2-97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2-56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. CONCLUSION: The LumiraDx™ assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling. TRIAL REGISTRATION NUMBER AND REGISTRATION DATE: DRKS00021220 and 01.04.2020.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral , Sensibilidade e Especificidade
8.
Liver Int ; 42(3): 532-540, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34817928

RESUMO

BACKGROUND AND AIMS: India has a significant burden of hepatitis C virus (HCV) infection and has committed to achieving national elimination by 2030. This will require a substantial scale-up in testing and treatment. The "HEAD-Start Project Delhi" aimed to enhance HCV diagnosis and treatment pathways among the general population. METHODS: A prospective study was conducted at 5 district hospitals (Arm 1: one-stop shop), 15 polyclinics (Arm 2: referral for viral load (VL) testing and treatment) and 62 screening camps (Arm 3: referral for treatment). HCV prevalence, retention in the HCV care cascade, and turn-around time were measured. RESULTS: Between January and September 2019, 37 425 participants were screened for HCV. The median (IQR) age of participants was 35 (26-48) years, with 50.4% male and 49.6% female. A significantly higher proportion of participants in Arm 1 (93.7%) and Arm 3 (90.3%) received a VL test compared with Arm 2 (52.5%, P < .001). Of those confirmed positive, treatment was initiated at significantly higher rates for participants in both Arms 1 (85.6%) and 2 (73.7%) compared to Arm 3 (41.8%, P < .001). Arm 1 was found to be a cost-saving strategy compared to Arm 2, Arm 3, and no action. CONCLUSIONS: Delivery of all services at a single site (district hospitals) resulted in a higher yield of HCV seropositive cases and retention compared with sites where participants were referred elsewhere for VL testing and/or treatment. The highest level of retention in the care cascade was also associated with the shortest turn-around times.


Assuntos
Hepacivirus , Hepatite C , Adulto , Estudos de Viabilidade , Feminino , Hepatite C/diagnóstico , Hepatite C/epidemiologia , Hepatite C/terapia , Humanos , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
EBioMedicine ; 75: 103774, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34959134

RESUMO

BACKGROUND: Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. METHODS: Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. FINDINGS: 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log10SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. INTERPRETATION: Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. FUNDING: Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité - Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19 , COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
BMJ Open ; 11(12): e055142, 2021 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-34952885

RESUMO

INTRODUCTION: To achieve the elimination of hepatitis C virus (HCV), substantial scale-up in access to testing and treatment is needed. This will require innovation and simplification of the care pathway, through decentralisation of testing and treatment to primary care settings and task-shifting to non-specialists. The objective of this study was to evaluate the feasibility and effectiveness of decentralisation of HCV testing and treatment using rapid diagnostic tests (RDTs) in primary healthcare clinics (PHCs) among high-risk populations, with referral of seropositive patients for confirmatory viral load testing and treatment. METHODS: This observational study was conducted between December 2018 and October 2019 at 25 PHCs in three regions in Malaysia. Each PHC was linked to one or more hospitals, for referral of seropositive participants for confirmatory testing and pretreatment evaluation. Treatment was provided in PHCs for non-cirrhotic patients and at hospitals for cirrhotic patients. RESULTS: During the study period, a total of 15 366 adults were screened at the 25 PHCs, using RDTs for HCV antibodies. Of the 2020 (13.2%) HCV antibody-positive participants, 1481/2020 (73.3%) had a confirmatory viral load test, 1241/1481 (83.8%) were HCV RNA-positive, 991/1241 (79.9%) completed pretreatment assessment, 632/991 (63.8%) initiated treatment, 518/632 (82.0%) completed treatment, 352/518 (68.0%) were eligible for a sustained virological response (SVR) cure assessment, 209/352 (59.4%) had an SVR cure assessment, and SVR was achieved in 202/209 (96.7%) patients. A significantly higher proportion of patients referred to PHCs initiated treatment compared with those who had treatment initiated at hospitals (71.0% vs 48.8%, p<0.001). CONCLUSIONS: This study demonstrated the effectiveness and feasibility of a simplified decentralised HCV testing and treatment model in primary healthcare settings, targeting high-risk groups in Malaysia. There were good outcomes across most steps of the cascade of care when treatment was provided at PHCs compared with hospitals.


Assuntos
Hepacivirus , Hepatite C , Adulto , Antivirais/uso terapêutico , Hepatite C/diagnóstico , Hepatite C/tratamento farmacológico , Humanos , Malásia , Atenção Primária à Saúde
11.
Infect Dis (Lond) ; 53(12): 947-952, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34445926

RESUMO

INTRODUCTION: Most SARS-CoV-2 antigen-detecting rapid diagnostic tests require nasopharyngeal sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable self-sampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. METHODS: This manufacturer-independent, prospective diagnostic accuracy study, compared professional anterior nasal and nasal mid-turbinate sampling for a WHO-listed SARS-CoV-2 antigen-detecting rapid diagnostic test. The second group of participants collected a nasal mid-turbinate sample themselves and underwent a professional nasopharyngeal swab for comparison. The reference standard was real-time polymerase chain reaction (RT-PCR) using combined oro-/nasopharyngeal sampling. Individuals with high suspicion of SARS-CoV-2 infection were tested. Sensitivity, specificity, and percent agreement were calculated. Self-sampling was observed without intervention. Feasibility was evaluated by observer and participant questionnaires. RESULTS: Among 132 symptomatic adults, both professional anterior nasal and nasal mid-turbinate sampling yielded a sensitivity of 86.1% (31/36 RT-PCR positives detected; 95%CI: 71.3-93.9) and a specificity of 100.0% (95%CI: 95.7-100). The positive percent agreement was 100% (95%CI: 89.0-100). Among 96 additional adults, self nasal mid-turbinate and professional nasopharyngeal sampling yielded an identical sensitivity of 91.2% (31/34; 95%CI 77.0-97.0). Specificity was 98.4% (95%CI: 91.4-99.9) with nasal mid-turbinate and 100.0% (95%CI: 94.2-100) with nasopharyngeal sampling. The positive percent agreement was 96.8% (95%CI: 83.8-99.8). Most participants (85.3%) considered self-sampling as easy to perform. CONCLUSION: Professional anterior nasal and nasal mid-turbinate sampling are of equivalent accuracy for an antigen-detecting rapid diagnostic test in ambulatory symptomatic adults. Participants were able to reliably perform nasal mid-turbinate sampling themselves, following written and illustrated instructions. Nasal self-sampling will facilitate scaling of SARS-CoV-2 antigen testing.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Conchas Nasais
12.
PLoS Med ; 18(8): e1003735, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34383750

RESUMO

BACKGROUND: SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers' instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies' heterogeneity in design and reporting. CONCLUSIONS: In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.


Assuntos
Teste Sorológico para COVID-19/métodos , Fatores Etários , Antígenos Virais/análise , COVID-19/diagnóstico , COVID-19/etiologia , Teste Sorológico para COVID-19/normas , Portador Sadio/diagnóstico , Portador Sadio/virologia , Humanos , Nasofaringe/virologia , Kit de Reagentes para Diagnóstico , Padrões de Referência , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Carga Viral
13.
J Clin Virol ; 141: 104874, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34144452

RESUMO

BACKGROUND: Considering the possibility of nasal self-sampling and the ease of use in performing SARS-CoV-2 antigen-detecting rapid diagnostic tests (Ag-RDTs), self-testing is a feasible option. OBJECTIVE: The goal of this study was a head-to-head comparison of diagnostic accuracy of patient self-testing with professional testing using a SARS-CoV-2 Ag-RDT. STUDY DESIGN: We performed a manufacturer-independent, prospective diagnostic accuracy study of nasal mid-turbinate self-sampling and self-testing with symptomatic adults using a WHO-listed SARS-CoV-2 Ag-RDT. Procedures were observed without intervention. For comparison, Ag-RDTs with nasopharyngeal sampling were professionally performed. Estimates of agreement, sensitivity, and specificity relative to RT-PCR on a combined oro-/nasopharyngeal sample were calculated. Feasibility was evaluated by observer and participant questionnaires. RESULTS: Among 146 symptomatic adults, 40 (27.4%) were RT-PCR-positive for SARS-CoV-2. Sensitivity with self-testing was 82.5% (33/40; 95% CI 68.1-91.3), and 85.0% (34/40; 95% CI 70.9-92.9) with professional testing. At high viral load (≥7.0 log10 SARS-CoV-2 RNA copies/ml), sensitivity was 96.6% (28/29; 95% CI 82.8-99.8) for both self- and professional testing. Deviations in sampling and testing were observed in 25 out of the 40 PCR-positives. Most participants (80.9%) considered the Ag-RDT as easy to perform. CONCLUSION: Laypersons suspected for SARS-CoV-2 infection were able to reliably perform the Ag-RDT and test themselves. Procedural errors might be reduced by refinement of the instructions for use or the product design/procedures. Self-testing allows more wide-spread and frequent testing. Paired with the appropriate information of the public about the benefits and risks, self-testing may have significant impact on the pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Antígenos Virais , Estudos de Viabilidade , Humanos , Estudos Prospectivos , RNA Viral , Autoteste , Sensibilidade e Especificidade
14.
PLoS One ; 16(5): e0247918, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34043631

RESUMO

OBJECTIVES: Diagnostics are essential for controlling the pandemic. Identifying a reliable and fast diagnostic device is needed for effective testing. We assessed performance and ease-of-use of the Abbott PanBio antigen-detecting rapid diagnostic test (Ag-RDT). METHODS: This prospective, multi-centre diagnostic accuracy study enrolled at two sites in Germany. Following routine testing with reverse-transcriptase polymerase chain reaction (RT-PCR), a second study-exclusive swab was performed for Ag-RDT testing. Routine swabs were nasopharyngeal (NP) or combined NP/oropharyngeal (OP) whereas the study-exclusive swabs were NP. To evaluate performance, sensitivity and specificity were assessed overall and in predefined sub-analyses accordingly to cycle-threshold values, days after symptom onset, disease severity and study site. Additionally, an ease-of-use assessment (EoU) and System Usability Scale (SUS) were performed. RESULTS: 1108 participants were enrolled between Sept 28 and Oct 30, 2020. Of these, 106 (9.6%) were PCR-positive. The Abbott PanBio detected 92/106 PCR-positive participants with a sensitivity of 86.8% (95% CI: 79.0% - 92.0%) and a specificity of 99.9% (95% CI: 99.4%-100%). The sub-analyses indicated that sensitivity was 95.8% in Ct-values <25 and within the first seven days from symptom onset. The test was characterized as easy to use (SUS: 86/100) and considered suitable for point-of-care settings. CONCLUSION: The Abbott PanBio Ag-RDT performs well for SARS-CoV-2 testing in this large manufacturer independent study, confirming its WHO recommendation for Emergency Use in settings with limited resources.


Assuntos
Teste Sorológico para COVID-19 , COVID-19 , Testes Imediatos , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/imunologia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Organização Mundial da Saúde
15.
Med Microbiol Immunol ; 210(4): 181-186, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34028625

RESUMO

In 2020, the World Health Organization (WHO) recommended two SARS-CoV-2 lateral flow antigen-detecting rapid diagnostics tests (Ag-RDTs), both initially with nasopharyngeal (NP) sample collection. Independent head-to-head studies are necessary for SARS-CoV-2 Ag-RDT nasal sampling to demonstrate comparability of performance with nasopharyngeal (NP) sampling. We conducted a head-to-head comparison study of a supervised, self-collected nasal mid-turbinate (NMT) swab and a professional-collected NP swab, using the Panbio™ Ag-RDT (distributed by Abbott). We calculated positive and negative percent agreement between the sampling methods as well as sensitivity and specificity for both sampling techniques compared to the reference standard reverse transcription polymerase chain reaction (RT-PCR). A SARS-CoV-2 infection could be diagnosed by RT-PCR in 45 of 290 participants (15.5%). Comparing the NMT and NP sampling the positive percent agreement of the Ag-RDT was 88.1% (37/42 PCR positives detected; CI 75.0-94.8%). The negative percent agreement was 98.8% (245/248; CI 96.5-99.6%). The overall sensitivity of Panbio with NMT sampling was 84.4% (38/45; CI 71.2-92.3%) and 88.9% (40/45; CI 76.5-95.5%) with NP sampling. Specificity was 99.2% (243/245; CI 97.1-99.8%) for both, NP and NMT sampling. The sensitivity of the Panbio test in participants with high viral load (> 7 log10 SARS-CoV-2 RNA copies/mL) was 96.3% (CI 81.7-99.8%) for both, NMT and NP sampling. For the Panbio supervised NMT self-sampling yields comparable results to NP sampling. This suggests that nasal self-sampling could be used for to enable scaled-up population testing.Clinical Trial DRKS00021220.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , Adulto , Antígenos Virais , COVID-19/imunologia , Teste de Ácido Nucleico para COVID-19 , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , RNA Viral , Sensibilidade e Especificidade , Carga Viral , Organização Mundial da Saúde
18.
PLoS One ; 14(10): e0223966, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31639145

RESUMO

Household contact studies of tuberculosis (TB) are a common way to study disease transmission dynamics. However these studies lack a mechanism for accounting for community transmission, which is known to be significant, particularly in high burden settings. We illustrate a statistical approach for estimating both the correlates with transmission of TB in a household setting and the probability of community transmission using a modified Bayesian mixed-effects model. This is applied to two household contact studies in Vitória, Brazil from 2008-2013 and Kampala, Uganda from 1995-2004 that enrolled households with an individual that was recently diagnosed with pulmonary TB. We estimate the probability of community transmission to be higher in Uganda (ranging from 0.21 to 0.69, depending on HHC age and HIV status of the index case) than in Brazil (ranging from 0.13 for young children to 0.50 in adults). These estimates are consistent with a higher overall burden of disease in Uganda compared to Brazil. Our method also estimates an increasing risk of community-acquired TB with age of the household contact, consistent with existing literature. This approach is a useful way to integrate the role of the community in understanding TB disease transmission dynamics in household contact studies.


Assuntos
Teorema de Bayes , Busca de Comunicante/métodos , Características da Família , Modelos Estatísticos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose Pulmonar/epidemiologia , Adolescente , Brasil/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Fatores de Risco , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Uganda/epidemiologia
19.
Open Forum Infect Dis ; 6(6): ofz184, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31205972

RESUMO

BACKGROUND: Epidemiologic data suggests that only a minority of tuberculosis (TB) patients are infectious. Cough aerosol sampling is a novel quantitative method to measure TB infectiousness. METHODS: We analyzed data from three studies conducted in Uganda and Brazil over a 13-year period. We included sputum acid fast bacilli (AFB) and culture positive pulmonary TB patients and used a cough aerosol sampling system (CASS) to measure the number of colony-forming units (CFU) of Mycobacterium tuberculosis in cough-generated aerosols as a measure for infectiousness. Aerosol data was categorized as: aerosol negative (CFU = 0) and aerosol positive (CFU > 0). Logistic regression models were built to identify factors associated with aerosol positivity. RESULTS: M. tuberculosis was isolated by culture from cough aerosols in 100/233 (43%) TB patients. In an unadjusted analysis, aerosol positivity was associated with fewer days of antituberculous therapy before CASS sampling (p = .0001), higher sputum AFB smear grade (p = .01), shorter days to positivity in liquid culture media (p = .02), and larger sputum volume (p = .03). In an adjusted analysis, only fewer days of TB treatment (OR 1.47 per 1 day of therapy, 95% CI 1.16-1.89; p = .001) was associated with aerosol positivity. CONCLUSION: Cough generated aerosols containing viable M. tuberculosis, the infectious moiety in TB, are detected in a minority of TB patients and rapidly become non-culturable after initiation of antituberculous treatment. Mechanistic studies are needed to further elucidate these findings.

20.
Tuberculosis (Edinb) ; 116: 1-7, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30983569

RESUMO

BACKGROUND: Rapid diagnosis of pulmonary tuberculosis (TB) is critical to TB control. However, many patients with paucibacillary TB disease remain undiagnosed. Current TB elimination goals require new tools to diagnose early disease. We evaluated performance of the Totally Optimized PCR (TOP) TB assay, a novel ultrasensitive molecular test. METHODS: We assessed analytical specificity against nontuberculous mycobacteria (NTM), and estimated the diagnostic accuracy of TOP in a pilot study in Brazil (n = 46) and a cross-sectional study in Boston (n = 60). We compared TOP results to culture and a composite reference standard (CRS). RESULTS: TOP exhibited no cross-reactivity against NTM. We tested 132 respiratory specimens from 106 patients with suspected pulmonary TB. The pilot demonstrated feasibility and 100% (95% CI 85-100) sensitivity in predominantly smear-positive specimens; TOP's specificity against solid media culture was low (58%, 37-77) but improved against a CRS (93%, 68-100). Similarly, when using the CRS in the Boston study, TOP (88%, 1-99) had greater sensitivity than solid or liquid media culture (25%, 3-65) and similar specificity (both 100%, 93-100). CONCLUSIONS: The TOP assay enables detection of M. tuberculosis in culture-negative paucibacillary disease. While the use of TOP for the diagnosis of paucibacillary disease will require further clinical validation, its high sensitivity indicate a more immediate utility as a rule out TB test.


Assuntos
Técnicas Bacteriológicas , DNA Bacteriano/genética , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase , Escarro/microbiologia , Tuberculose Pulmonar/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Boston , Brasil , Estudos Transversais , DNA Bacteriano/isolamento & purificação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/isolamento & purificação , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Tuberculose Pulmonar/microbiologia , Fluxo de Trabalho , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...