Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
2.
Bone Marrow Transplant ; 56(7): 1550-1557, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33514918

RESUMO

Patients with advanced Ewing sarcoma (AES) carry a poor prognosis. Retrospectively, we analyzed 66 AES patients treated with allogeneic stem cell transplantation (allo-SCT) receiving HLA-mismatched (group A, n = 39) versus HLA-matched grafts (group B, n = 27). Median age at diagnosis was 13 years, and 15 years (range 3-49 years) at allo-SCT. The two groups did not differ statistically in distribution of gender, age, remission status/number of relapses at allo-SCT, or risk stratum. 9/39 (23%) group A versus 2/27 (7%) group B patients developed severe acute graft versus host disease (GvHD). Of patients alive at day 100, 7/34 (21%) group A versus 9/19 (47%) group B patients had developed chronic GvHD. In group A, 33/39 (85%) versus 20/27 (74%) group B patients died of disease and 1/39 (3%) versus 1/27 (4%) patients died of complications, respectively. Altogether 12/66 (18%) patients survived in CR. Median EFS 24 months after allo-SCT was 20% in both groups, median OS was 27% (group A) versus 17% (group B), respectively. There was no difference in EFS and OS in AES patients transplanted with HLA-mismatched versus HLA-matched graft in univariate and multivariate analyses. In this analysis, CR at allo-SCT is a condition for survival (p < 0.02).


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Sarcoma de Ewing , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estudos Retrospectivos , Sarcoma de Ewing/terapia , Condicionamento Pré-Transplante , Adulto Jovem
3.
Environ Sci Pollut Res Int ; 24(4): 3352-3362, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27864739

RESUMO

During biological effect monitoring studies of endocrine active compounds with the snail Assiminea grayana in 2007-2013, reproductive disorders including atresia, transformation of capsule/albumen glands into prostates in females and ovotestis, transformation of prostates to capsule/albumen glands, disruption of spermatogenesis, and calcification of tubules in males, were encountered in several years. The search of sources of endocrine active substances was first directed to antifouling biocides from paint particles and extended to leaching compounds from polymeric materials. In contrast to the reference sites, most of the observed disorders occurred at a station near harbors and dockyards polluted with residues from antifouling paints and polymeric materials. Beside of investigations about the potential ingestion of polymer particles by the snails, further investigations of compounds of polymeric materials with endocrine potential should follow.


Assuntos
Reprodução/efeitos dos fármacos , Animais , Desinfetantes/farmacologia , Monitoramento Ambiental , Feminino , Alemanha , Masculino , Mar do Norte , Pintura/análise , Caramujos/efeitos dos fármacos , Fatores de Tempo , Poluentes Químicos da Água/análise
4.
J Appl Polym Sci ; 121(1): 144-153, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21572577

RESUMO

Novel urethane shape-memory polymers (SMPs) of significant industrial relevance have been synthesized and characterized. Chemically crosslinked SMPs have traditionally been made in a one-step polymerization of monomers and crosslinking agents. However, these new post-polymerization crosslinked SMPs can be processed into complex shapes by thermoplastic manufacturing methods and later crosslinked by heat exposure or by electron beam irradiation. Several series of linear, olefinic urethane polymers were made from 2-butene-1,4-diol, other saturated diols, and various aliphatic diisocyanates. These thermoplastics were melt-processed into desired geometries and thermally crosslinked at 200°C or radiation crosslinked at 50 kGy. The SMPs were characterized by solvent swelling and extraction, differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), tensile testing, and qualitative shape-recovery analysis. Swelling and DMA results provided concrete evidence of chemical crosslinking, and further characterization revealed that the urethanes had outstanding mechanical properties. Key properties include tailorable transitions between 25 and 80°C, tailorable rubbery moduli between 0.2 and 4.2 MPa, recoverable strains approaching 100%, failure strains of over 500% at T(g), and qualitative shape-recovery times of less than 12 seconds at body temperature (37°C). Because of its outstanding thermo-mechanical properties, one polyurethane was selected for implementation in the design of a complex medical device. These post-polymerization crosslinked urethane SMPs are an industrially relevant class of highly processable shape-memory materials.

5.
Biomed Mater ; 3(1): 015010, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18458497

RESUMO

Shape-memory polymers (SMPs) are being increasingly proposed for use in biomedical devices. This paper investigates the cytotoxicity, surface characteristics and thermomechanics of two acrylate-based SMP networks as a function of sterilization using a minimal essential media elution test, FTIR-ATR and dynamic mechanical analysis (DMA). Networks sterilized by low-temperature plasma elicited a cytotoxic response and are shown to completely destroy the cell monolayer. FTIR-ATR analysis showed evidence of surface oxidation with an increase and broadening of the absorbance peak from approximately 3500 to 3100 cm(-1), which is associated with an increase in hydroxyl groups. DMA revealed small, but statistically significant, differences in reduction of the glass transition temperatures of both networks when sterilized with gamma irradiation. One network showed an increase in rubbery modulus, which is an indication of crosslink density, after gamma irradiation. Lastly, practical sterilization concerns of SMP devices are discussed in light of the different methods.


Assuntos
Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Sobrevivência Celular/efeitos dos fármacos , Polímeros/química , Polímeros/toxicidade , Esterilização/métodos , Elasticidade , Teste de Materiais , Conformação Molecular , Estresse Mecânico , Termodinâmica
6.
Minim Invasive Neurosurg ; 48(3): 142-8, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16015490

RESUMO

Therapeutic radiation and subsequent detection of tumor cell death has been performed mainly in vitro systems, making it difficult to accurately characterize the mechanisms of tumor cell death after radiosurgery. To better characterize what occurs to glioma cells after radiation therapy, we developed a rat model using the 9L gliosarcoma cell line implanted reproducibly to the caudate nucleus in rats. After 1 Gy radiation, 9L tumors in vivo induced mainly necrosis (determined by trypan blue exclusion) of 10 - 74 % at 6 - 72 hours post-radiation. This is in contrast to a previous in vitro study which demonstrated that 18 Gy of radiation induces considerably less cell death as determined by trypan blue exclusion (approximately 20 - 25 % at 6 - 72 hours post-radiation). However, significant amounts of apoptosis were detected as early as 6 hours after radiation. Apoptosis determination was by annexin V (marker of early apoptosis) and propidium iodide (marker of membrane stability) staining followed by flow cytometry detection. When caspase 3 and caspase 8 enzymatic activities (mediators of apoptosis) were measured from freshly explanted tumor cells, peak activity was found 6 hours after 1 Gy radiation (p < 0.01). Taken together, these data indicate the presence of apoptosis early after radiation therapy (1 Gy) which progressed to necrosis in a unique in vivo model of gliosarcoma that may prove useful in determining new therapeutic approaches to radiation therapy and tumor cell biology.


Assuntos
Apoptose/efeitos da radiação , Neoplasias Encefálicas/cirurgia , Núcleo Caudado/cirurgia , Gliossarcoma/cirurgia , Radiocirurgia , Animais , Neoplasias Encefálicas/metabolismo , Caspase 3 , Caspase 8 , Caspases/metabolismo , Núcleo Caudado/metabolismo , Modelos Animais de Doenças , Gliossarcoma/metabolismo , Masculino , Ratos , Ratos Endogâmicos F344 , Fatores de Tempo
7.
Minim Invasive Neurosurg ; 47(5): 266-72, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15578338

RESUMO

Despite the proven efficacy of radiosurgery for the treatment of brain tumors, limited histological information is available after treatment that might allow a better understanding of the relationship between radiation dose, the volume treated, and the response of the surrounding brain to the delivered radiation. The use of an animal model could provide the opportunity to clarify these relationships and answer several other key questions arising in clinical practice. We show here that treatment of small animals with radiosurgery is feasible using a robotically controlled linear accelerator, which offers the advantages of radiosurgery and preserves the potential for fractionated regimens without rigid immobilization. Specifically, we demonstrate the use of a robotically driven linear accelerator to provide radiosurgical treatment to a rat brain tumor model.


Assuntos
Neoplasias Encefálicas/cirurgia , Gliossarcoma/cirurgia , Radiocirurgia/instrumentação , Robótica , Cirurgia Assistida por Computador/instrumentação , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Modelos Animais de Doenças , Gliossarcoma/diagnóstico por imagem , Gliossarcoma/patologia , Masculino , Ratos , Ratos Endogâmicos F344 , Tomografia Computadorizada por Raios X
8.
Appl Environ Microbiol ; 67(1): 198-205, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11133446

RESUMO

We have applied molecular approaches, including PCR-based detection strategies and DNA fingerprinting methods, to study the ecology of Listeria monocytogenes in food processing environments. A total of 531 samples, including raw fish, fish during the cold-smoking process, finished product, and environmental samples, were collected from three smoked fish processing facilities during five visits to each facility. A total of 95 (17.9%) of the samples tested positive for L. monocytogenes using a commercial PCR system (BAX for Screening/Listeria monocytogenes), including 57 (27.7%) environmental samples (n = 206), 8 (7.8%) raw material samples (n = 102), 23 (18.1%) samples from fish in various stages of processing(n = 127), and 7 (7.3%) finished product samples (n = 96). L. monocytogenes was isolated from 85 samples (16.0%) using culture methods. Used in conjunction with a 48-h enrichment in Listeria Enrichment Broth, the PCR system had a sensitivity of 91.8% and a specificity of 96.2%. To track the origin and spread of L. monocytogenes, isolates were fingerprinted by automated ribotyping. Fifteen different ribotypes were identified among 85 isolates tested. Ribotyping data established possible contamination patterns, implicating raw materials and the processing environment as potential sources of finished product contamination. Analysis of the distribution of ribotypes revealed that each processing facility had a unique contamination pattern and that specific ribotypes persisted in the environments of two facilities over time (P < or = 0.0006). We conclude that application of molecular approaches can provide critical information on the ecology of different L. monocytogenes strains in food processing environments. This information can be used to develop practical recommendations for improved control of this important food-borne pathogen in the food industry.


Assuntos
Monitoramento Ambiental/métodos , Peixes , Indústria de Processamento de Alimentos , Listeria monocytogenes/genética , Listeria monocytogenes/isolamento & purificação , Animais , Ecologia , Peixes/microbiologia , Humanos , Listeria monocytogenes/classificação , Listeriose/microbiologia , Listeriose/transmissão , Reação em Cadeia da Polimerase , Ribotipagem
9.
Biophys J ; 79(6): 2858-66, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11106594

RESUMO

Fluorescence correlation spectroscopy (FCS) has proven to be a powerful technique with single-molecule sensitivity. Recently, it has found a complement in the form of fluorescence intensity distribution analysis (FIDA). Here we introduce a fluorescence fluctuation method that combines the features of both techniques. It is based on the global analysis of a set of photon count number histograms, recorded with multiple widths of counting time intervals simultaneously. This fluorescence intensity multiple distributions analysis (FIMDA) distinguishes fluorescent species on the basis of both the specific molecular brightness and the translational diffusion time. The combined information, extracted from a single measurement, increases the readout effectively by one dimension and thus breaks the individual limits of FCS and FIDA. In this paper a theory is introduced that describes the dependence of photon count number distributions on diffusion coefficients. The theory is applied to a series of photon count number histograms corresponding to different widths of counting time intervals. Although the ability of the method to determine specific brightness values, diffusion times, and concentrations from mixtures is demonstrated on simulated data, its experimental utilization is shown by the determination of the binding constant of a protein-ligand interaction exemplifying its broad applicability in the life sciences.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal , Microscopia Confocal/métodos , Espectrometria de Fluorescência/métodos , Sequência de Aminoácidos , Difusão , Receptores ErbB/química , Receptores ErbB/metabolismo , Proteína Adaptadora GRB2 , Microscopia Confocal/instrumentação , Modelos Teóricos , Oligopeptídeos/química , Fragmentos de Peptídeos/química , Proteínas/química , Proteínas/metabolismo , Sensibilidade e Especificidade , Espectrometria de Fluorescência/instrumentação , Fatores de Tempo
10.
Biophys J ; 78(4): 1703-13, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10733953

RESUMO

A method of sample analysis is presented which is based on fitting a joint distribution of photon count numbers. In experiments, fluorescence from a microscopic volume containing a fluctuating number of molecules is monitored by two detectors, using a confocal microscope. The two detectors may have different polarizational or spectral responses. Concentrations of fluorescent species together with two specific brightness values per species are determined. The two-dimensional fluorescence intensity distribution analysis (2D-FIDA), if used with a polarization cube, is a tool that is able to distinguish fluorescent species with different specific polarization ratios. As an example of polarization studies by 2D-FIDA, binding of 5'-(6-carboxytetramethylrhodamine) (TAMRA)-labeled theophylline to an anti-theophylline antibody has been studied. Alternatively, if two-color equipment is used, 2D-FIDA can determine concentrations and specific brightness values of fluorescent species corresponding to individual labels alone and their complex. As an example of two-color 2D-FIDA, binding of TAMRA-labeled somatostatin-14 to the human type-2 high-affinity somatostatin receptors present in stained vesicles has been studied. The presented method is unusually accurate among fluorescence fluctuation methods. It is well suited for monitoring a variety of molecular interactions, including receptors and ligands or antibodies and antigens.


Assuntos
Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Algoritmos , Reações Antígeno-Anticorpo , Fenômenos Biofísicos , Biofísica , Estudos de Avaliação como Assunto , Polarização de Fluorescência/instrumentação , Polarização de Fluorescência/métodos , Polarização de Fluorescência/estatística & dados numéricos , Corantes Fluorescentes , Humanos , Microscopia Confocal/instrumentação , Microscopia Confocal/estatística & dados numéricos , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/estatística & dados numéricos , Modelos Teóricos , Fótons , Receptores de Somatostatina/metabolismo , Rodaminas , Somatostatina/metabolismo , Teofilina/análise , Teofilina/imunologia
11.
Phys Med Biol ; 45(2): 511-28, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10701518

RESUMO

A cone-beam computed tomography (CT) system utilizing a proton beam has been developed and tested. The cone beam is produced by scattering a 160 MeV proton beam with a modifier that results in a signal in the detector system, which decreases monotonically with depth in the medium. The detector system consists of a Gd2O2S:Tb intensifying screen viewed by a cooled CCD camera. The Feldkamp-Davis-Kress cone-beam reconstruction algorithm is applied to the projection data to obtain the CT voxel data representing proton stopping power. The system described is capable of reconstructing data over a 16 x 16 x 16 cm3 volume into 512 x 512 x 512 voxels. A spatial and contrast resolution phantom was scanned to determine the performance of the system. Spatial resolution is significantly degraded by multiple Coulomb scattering effects. Comparison of the reconstructed proton CT values with x-ray CT derived proton stopping powers shows that there may be some advantage to obtaining stopping powers directly with proton CT. The system described suggests a possible practical method of obtaining this measurement in vivo.


Assuntos
Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Calibragem , Processamento de Imagem Assistida por Computador , Prótons , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
12.
Proc Natl Acad Sci U S A ; 96(24): 13756-61, 1999 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-10570145

RESUMO

A methodology, fluorescence-intensity distribution analysis, has been developed for confocal microscopy studies in which the fluorescence intensity of a sample with a heterogeneous brightness profile is monitored. An adjustable formula, modeling the spatial brightness distribution, and the technique of generating functions for calculation of theoretical photon count number distributions serve as the two cornerstones of the methodology. The method permits the simultaneous determination of concentrations and specific brightness values of a number of individual fluorescent species in solution. Accordingly, we present an extremely sensitive tool to monitor the interaction of fluorescently labeled molecules or other microparticles with their respective biological counterparts that should find a wide application in life sciences, medicine, and drug discovery. Its potential is demonstrated by studying the hybridization of 5'-(6-carboxytetramethylrhodamine)-labeled and nonlabeled complementary oligonucleotides and the subsequent cleavage of the DNA hybrids by restriction enzymes.


Assuntos
DNA/análise , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Fluorescência , Corantes Fluorescentes , Computação Matemática , Hibridização de Ácido Nucleico , Oligodesoxirribonucleotídeos/análise , Fótons , Rodaminas
14.
Med Phys ; 25(7 Pt 1): 1212-6, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9682208

RESUMO

The Photon Radiosurgery System is a miniature x-ray device developed for the treatment of small intracranial neoplasms. The x-rays are generated at the tip of a 10-cm-long, 3-mm-diam probe with a nearly isotropic distribution. Results from measurements of the two-dimensional dose distribution around the x-ray source are presented using two methods: (1) dose measurement with an ionization chamber and a water phantom system and (2) dose measurement with radiochromic film and a solid water phantom. The shape of the two angular dose distributions in the axial plane agree with each other to with approximately 10% and the dose at 10 mm from the source, orthogonal to the probe axis, was about 20% lower than at the same distance along the axis. The relative dose difference of 20% corresponds to a change in distance from the source of +/- 0.3 mm at 10 mm. It is shown that the anisotropy of radiation distribution in the axial plane can be improved to approximately 10% by adjusting the electron beam with a 12% reduction in the overall radiation output.


Assuntos
Miniaturização/instrumentação , Radiocirurgia/instrumentação , Terapia por Raios X/instrumentação , Calibragem , Relação Dose-Resposta à Radiação , Imagens de Fantasmas , Radiometria/instrumentação , Água , Filme para Raios X
15.
Ann Thorac Surg ; 65(4): 1032-8, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9564923

RESUMO

BACKGROUND: The impact of allograft valve viability on valve durability remains controversial. Analyses of our clinical results have demonstrated the superiority of the cryopreserved valve viable at the time of implantation over the 4 degrees C stored valve nonviable at the time of implantation. In this study, we quantitatively assessed the effects on viability of current and past valve-processing protocols at The Prince Charles Hospital. METHODS: The viability of pulmonary valves was quantitatively analyzed by thin-layer autoradiography to assess the effects of donor type, antibiotics, and valve storage. RESULTS: Control valve segments obtained from beating-heart donor valves had a higher initial viability (0.92+/-0.02) than nonbeating-heart donor valves (0.66+/-0.03). Cryopreservation after low-dose antibiotic sterilization significantly reduced viability to 50% to 60% of the control, and in the presence of amphotericin B, viability dropped further to 10% to 36% of the control. After 7 days' storage at 4 degrees C, viability was reduced to 2% of control and to 0% viability after 21 days. CONCLUSIONS: For maximal preimplantation viability, valves should be procured as soon as possible after cessation of heart beat and should be cryopreserved if they are not to be clinically implanted within 1 to 2 days. Amphotericin B should not be used in conjunction with cryopreservation if viability is to be maximized.


Assuntos
Preservação de Órgãos , Valva Pulmonar/transplante , Anfotericina B/uso terapêutico , Análise de Variância , Antibacterianos/uso terapêutico , Antifúngicos/uso terapêutico , Autorradiografia , Contagem de Células , Corantes , Criopreservação , Crioprotetores/uso terapêutico , Dimetil Sulfóxido/uso terapêutico , Fibroblastos/patologia , Sobrevivência de Enxerto , Humanos , Esterilização , Doadores de Tecidos/classificação , Sobrevivência de Tecidos , Obtenção de Tecidos e Órgãos/métodos , Transplante Homólogo
16.
Neurosurgery ; 40(3): 510-6; discussion 516-7, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9055290

RESUMO

OBJECTIVE: We report the design and initial characterization of the dosimetry and radiobiology of a novel device for interstitial stereotactic radiosurgery. INSTRUMENTATION: The device is lightweight, handheld, and battery-powered, and it emits x-ray radiation from the tip of a probe 3 mm in diameter by 10 cm in length. METHODS: The dosimetry was characterized by two independent methods: thermoluminescent dosimeters and radiochromic film. The radiobiology was characterized by in vivo irradiation of rat liver, dog liver, and dog brain. The animals were killed at varying intervals of time, and histological examinations were performed. Heat transfer from the probe to dog brain was studied in vivo by placing thermocouple sensors around the probe tip before irradiating. RESULTS: Both dosimetric methods showed a steep dose-distance fall-off relationship (proportional to the reciprocal of the cube of the distance from the probe tip). Rats and dogs that were killed weeks to months after liver irradiation tended to have sharply demarcated lesions. Liver enzyme levels, measured serially in the dogs, did not give evidence of chronic inflammation. Histological examination of the brains of dogs that were killed acutely after irradiation did not show evidence of inflammation, edema, or hemorrhage. The tissue temperature elevation 1 cm from the tip never exceeded 0.5 degree C, thereby excluding hyperthermia as a significant contributor to the formation of lesions. CONCLUSIONS: Because this device requires relatively few supporting resources, has sharp dosimetric properties, and seems to be safe, it may be useful as a clinical tool for interstitial stereotactic radiosurgery.


Assuntos
Dosimetria Fotográfica/instrumentação , Radiocirurgia/instrumentação , Dosimetria Termoluminescente/instrumentação , Animais , Encéfalo/patologia , Encéfalo/cirurgia , Cães , Desenho de Equipamento , Humanos , Fígado/patologia , Fígado/cirurgia , Ratos
17.
J Thorac Cardiovasc Surg ; 112(5): 1260-6; discussion 1266-7, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8911322

RESUMO

OBJECTIVE: The nature and magnitude of the immunologic response to implantation of human cryopreserved aortic valve allografts was investigated. METHODS: Twenty aortic valve allograft recipients were investigated for donor-specific antibody and T-cell-mediated responses with serial flow cytometric and microlymphocytotoxic crossmatch assays and one-way mixed lymphocyte cultures. RESULTS: Donor-specific immunoglobulin G antibodies to class I and II human leukocyte antigens were first detected in the serum of all aortic valve allograft recipients at 30 days after implantation and persisted in substantial amounts in all but one of the recipients at day 365. Recipient T-cell alloreactivity toward donor lymphocytes was significantly increased at day 30 compared with levels before and 10 days after operation. CONCLUSIONS: Cryopreserved aortic valve allografts elicit a substantial allogeneic response in recipients. This alloreactivity may contribute to the observed morphologic changes in aortic valve allografts and eventual long-term deterioration of allograft function.


Assuntos
Valva Aórtica/transplante , Imunologia de Transplantes , Adulto , Idoso , Valva Aórtica/imunologia , Criopreservação , Feminino , Citometria de Fluxo , Doenças das Valvas Cardíacas/imunologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Isoanticorpos/análise , Teste de Cultura Mista de Linfócitos , Masculino , Pessoa de Meia-Idade , Linfócitos T Citotóxicos , Transplante Homólogo/imunologia
18.
Appl Radiat Isot ; 47(11-12): 1197-9, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9022180

RESUMO

We report a series of measurements directed to assess the suitability of alanine as a mailable dosimeter for dosimetry quality assurance of proton radiation therapy beams. These measurements include dose-response of alanine at 140 MeV, and comparison of response vs energy with a parallel plate ionization chamber. All irradiations were made at the Harvard Cyclotron Laboratory, and the dosimeters were read at NIST. The results encourage us that alanine could be expected to serve as a mailable dosimeter with systematic error due to differential energy response no greater than 3% when doses of 25 Gy are used.


Assuntos
Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Terapia com Prótons , Radiometria/métodos , Dosagem Radioterapêutica , Alanina/química , Relação Dose-Resposta à Radiação , Espectroscopia de Ressonância de Spin Eletrônica/normas , Espectroscopia de Ressonância de Spin Eletrônica/estatística & dados numéricos , Estudos de Avaliação como Assunto , Radicais Livres/análise , Radicais Livres/efeitos da radiação , Humanos , Radiometria/instrumentação , Radiometria/normas , Dosagem Radioterapêutica/normas , Radioterapia de Alta Energia
19.
Appl Radiat Isot ; 47(11-12): 1533-8, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9022199

RESUMO

We have studied the ESR response of proton-irradiated (in vitro) bone. The ESR response as a function of proton (E = 105 MeV) dose to bone was linear from 0 to 50 Gy and similar to the photon (E = 6 MV) dose response. The ESR depth response (Bragg) curve was depressed as compared to a depth-response curve determined with a parallel plate ionization chamber (PPIC). There was a short-term ESR signal fade in the Bragg peak region, likely attributable to the organic component in bone. We are continuing to investigate these latter two effects.


Assuntos
Osso e Ossos/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Terapia com Prótons , Radiometria/métodos , Espectroscopia de Ressonância de Spin Eletrônica/estatística & dados numéricos , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Dosagem Radioterapêutica , Radioterapia de Alta Energia
20.
Radiother Oncol ; 41(2): 169-77, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9004361

RESUMO

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.


Assuntos
Prótons , Radiometria/instrumentação , Radioterapia de Alta Energia , Calibragem , Radioisótopos de Cobalto , Humanos , Radiometria/normas , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...