Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Cardiovasc Diagn Ther ; 5(6): 414-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26675281

RESUMO

BACKGROUND: The present study aimed to evaluate the clinical performance, in the daily practice of a busy catheterization laboratory, of a novel drug-eluting stent (DES) built with an ultra-thin-strut metallic platform, eluting sirolimus at low doses, abluminal coated with biodegradable polymers, and mounted in a low-compliant delivery system. METHODS: Prospective, single-arm study, comprising all consecutive patients undergoing percutaneous coronary intervention (PCI) with the Inspiron™ sirolimus-eluting stent (SES) (Scitech, Aparecida de Goiania, Brazil). The primary endpoint was the occurrence of major adverse cardiac events (MACE) [cardiac death, non-PCI related myocardial infarction (MI), or target vessel revascularization (TVR)]. RESULTS: A total of 470 patients were included, from which 51.3% were diabetics, 33.8% had triple-vessel disease, 15.3% had heart failure, 38.9% had at least one bifurcation treated, 19.8% were treated for a bare metal stent restenosis, and 61.9% had at least one type C lesion; one or more of these features were found in 96.0%. At 300 days, the rate target lesion revascularization was 5.4% and the rate of MACE was 8.1%. The incidence of definite or probable stent thrombosis was 0.4%, with no cases between 30 and 300 days. CONCLUSIONS: The novel stent is associated with excellent short and mid-term clinical outcomes in patients treated with PCI in the daily practice.

2.
Arq. bras. cardiol ; 105(5): 487-492, Nov. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-764993

RESUMO

Background:Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention.Objective:To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated.Results:A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001).Conclusion:Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.


Fundamento:Uma série de vantagens e desvantagens tem sido descrita para a intervenção coronária percutânea ad hoc, como a realizada ao mesmo tempo que o cateterismo diagnóstico, porém pouco se sabe sobre a exposição radiológica desse procedimento, comparado com a intervenção estadiada, ou seja, em dois momentos.Objetivo:Comparar a dose de radiação utilizada na angioplastia ad hoc com a angioplastia estadiada.Métodos:O produto de dose por área e o Kerma total foram mensurados, somando-se ambas as fases de diagnóstico e terapêutica. Além disso, foram computados o tempo total de fluoroscopia e o número de filmagens.Resultados:Um total de 568 pacientes consecutivos foram tratados com intervenção coronária percutânea ad hoc (n = 320) ou estadiada (n = 248). À admissão, o grupo do ad hoc apresentava menos hipertensão (74,1% vs. 81,9%; p = 0,035), dislipidemia (57,8% vs. 67,7%; p = 0,02) e doença triarterial (38,8% vs. 50,4%; p = 0,015). O grupo ad hoc foi exposto a doses significativamente menores de radiação, mesmo após ajuste para as diferenças basais entre os grupos. O grupo ad hoc foi exposto a uma dose de produto de dose por área total de 119,7 ± 70,7 Gycm2 enquanto que os pacientes estadiados foram expostos a uma dose de 139,2 ± 75,3 Gycm2 (p < 0,001).Conclusão:A intervenção coronária percutânea ad hoc reduziu a exposição radiológica, em comparação com procedimentos diagnósticos e terapêuticos realizados em tempos separados.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Angiografia Coronária , Cateterismo Cardíaco/métodos , Stents Farmacológicos , Fluoroscopia/métodos , Estudos Prospectivos , Monitoramento de Radiação , Fatores de Risco , Estatísticas não Paramétricas , Fatores de Tempo
3.
Case Rep Cardiol ; 2015: 703646, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26451260

RESUMO

Aneurysms of the sinus of Valsalva are very rare and mostly located in the right coronary sinus. They might course with dyspnea, fatigue, and acute coronary syndromes. We present herein an extremely rare case report of a 61-year-old woman diagnosed with external left main coronary compression by a giant aneurysm of the left sinus of Valsalva, which was successfully managed with percutaneous coronary intervention.

4.
Comput Med Imaging Graph ; 46 Pt 2: 237-48, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26433615

RESUMO

Intravascular optical coherence tomography (IV-OCT) is an in-vivo imaging modality based on the intravascular introduction of a catheter which provides a view of the inner wall of blood vessels with a spatial resolution of 10-20 µm. Recent studies in IV-OCT have demonstrated the importance of the bifurcation regions. Therefore, the development of an automated tool to classify hundreds of coronary OCT frames as bifurcation or nonbifurcation can be an important step to improve automated methods for atherosclerotic plaques quantification, stent analysis and co-registration between different modalities. This paper describes a fully automated method to identify IV-OCT frames in bifurcation regions. The method is divided into lumen detection; feature extraction; and classification, providing a lumen area quantification, geometrical features of the cross-sectional lumen and labeled slices. This classification method is a combination of supervised machine learning algorithms and feature selection using orthogonal least squares methods. Training and tests were performed in sets with a maximum of 1460 human coronary OCT frames. The lumen segmentation achieved a mean difference of lumen area of 0.11 mm(2) compared with manual segmentation, and the AdaBoost classifier presented the best result reaching a F-measure score of 97.5% using 104 features.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Aprendizado de Máquina Supervisionado , Tomografia de Coerência Óptica/métodos , Interpretação Estatística de Dados , Humanos , Análise dos Mínimos Quadrados , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Arq Bras Cardiol ; 105(5): 487-92, 2015 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-26351982

RESUMO

BACKGROUND: Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention. OBJECTIVE: To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated. RESULTS: A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001). CONCLUSION: Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.


Assuntos
Intervenção Coronária Percutânea/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Cateterismo Cardíaco/métodos , Angiografia Coronária , Stents Farmacológicos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Monitoramento de Radiação , Fatores de Risco , Estatísticas não Paramétricas , Fatores de Tempo
6.
Cardiovasc Diagn Ther ; 5(2): 113-21, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25984451

RESUMO

BACKGROUND: Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). METHODS: In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. RESULTS: According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. CONCLUSIONS: The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA