Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(12): e14137, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37712892

RESUMO

INTRODUCTION: In order to understand the interaction processes of photons and electrons of the CyberKnife VSI-System, a modeling of the LINAC head must take place. Here, a Monte Carlo simulation can help. By comparing the measured data with the simulation data, the agreement can be checked. MATERIALS AND METHODS: For the Monte Carlo simulations, the toolkit EGSnrc with the user codes BEAMnrc and DOSXZYnrc was used. The CyberKnife VSI-System has two collimation systems to define the field size of the beam. On the one hand, it has 12 circular collimators and, on the other, an IRIS-aperture. The average energy, final source width, dose profiles, and output factors in a voxel-based water phantom were determined and compared to the measured data. RESULTS: The average kinetic energy of the electron beam for the CyberKnife VSI LINAC head is 6.9 MeV, with a final source width of 0.25 cm in x-direction and 0.23 cm in y-direction. All simulated dose profiles for both collimation systems were able to achieve a global gamma criterion of 1%/1 mm to the measured data. For the output factors, the deviation from simulated to measured data is < 1% from a field size of 12.5 mm for the circular collimators and from a field size of 10 mm for the IRIS-aperture. CONCLUSION: The beam characteristics of the CyberKnife VSI LINAC head could be exactly simulated with Monte Carlo simulation. Thus, in the future, this model can be used as a basis for electronic patient-specific QA or to determine scattering processes of the LINAC head.


Assuntos
Aceleradores de Partículas , Fótons , Humanos , Método de Monte Carlo , Simulação por Computador , Imagens de Fantasmas , Dosagem Radioterapêutica , Radiometria , Planejamento da Radioterapia Assistida por Computador
2.
J Appl Clin Med Phys ; 24(12): e14144, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37672349

RESUMO

INTRODUCTION: Two optimization algorithms VOLO™ and sequential optimization algorithm (SEQU) are compared in the Precision® treatment planning system from Accuray® for stereotactic radiosurgery and stereotactic body radiotherapy (SBRT) treatment plans. The aim is to compare the two algorithms to assess if VOLO™ is better of SEQU in certain treatment site. MATERIALS AND METHODS: Sixty clinical treatment cases were compared. Entities include Acoustic neuroma (AN), lung metastases, and liver metastases. In each entity, 10 SEQU and 10 VOLO™ treatment plans were optimized. The Ray-Tracing calculation algorithm was used for all treatment plans and the treatments were planned exclusively with fixed cones (5-50 mm). The number of nodes, beams, total MU, and treatment time were compared. Conformity index (CI), new conformity index (nCI), homogeneity index (HI), gradient index (GI), and target coverage were examined for agreement. Dmin , Dmean , Dmax , D100%, D98%, and D2% dose in the target volume as well as exposure to organs at risk was checked. To determine peripheral doses, the isodose volumes from V10% to V98% were evaluated. RESULTS: AN treatment plans showed significant differences for the number of nodes, beams, total MU, treatment time, D98%, D100% for the target volume, and the doses for all organs at risk. VOLO™ achieved better results on average. Total MU, treatment time, coverage, and D98% are significantly better for VOLO™ for lung metastases. For liver metastases, a significant reduction in number of nodes, total MU, and treatment time was observed for VOLO™ plans. The mean target coverage increased slightly with VOLO™, while the mean CI deteriorated slightly. The averages of Dmin , Dmean , D98%, D100%, and V80% resulted in a significant increase for VOLO™. CONCLUSION: The results of the present study indicate that VOLO™ should be used in place of SEQU as a standard for AN cases moving forward. Despite the lack of significance in the lung and liver cases, VOLO™ optimization is recommended because OAR sparing was similar, but coverage, Dmin , and Dmean were increased, and thus better tumor control can be expected.


Assuntos
Neoplasias Hepáticas , Neoplasias Pulmonares , Neuroma Acústico , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neuroma Acústico/cirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Algoritmos , Órgãos em Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...