Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur Rev Med Pharmacol Sci ; 26(6): 2000-2017, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35363351

RESUMO

Emergency or postoperative pain often represents an authentic challenge in patients who were already on opioid treatment for chronic pain. Thus, their management requires not only the physician's ability to treat acute pain, but also competence in switching the opioid that lost efficacy. Different aspects should be considered, such as opioids titration, switching, association and equianalgesia. The objective of this paper is to provide a narrative review, which has been elaborated and discussed among clinicians through an iterative process involving development and review of the draft during two web-based meetings and via email. This expert opinion aims to facilitate the correct opioid use through appropriate practices with a focus on pain treatment in emergency and postoperative pain. Equianalgesia tables were reviewed and integrated by clinicians and researchers with expertise in anesthesia, postoperative medicine, intensive care, emergency medicine pharmacology and addiction medicine. Special populations (liver/kidney failure, elder, pediatric, pregnancy/lactation) are discussed in detail along with other critical scenarios, such as: (i) rapid pain worsening in chronic pain (aggravating pain due to disease progression or tolerance development to analgesic therapy); (ii) acute pain on maintenance treatment; and (iii) pain management of complicated patients in emergency care. Extended and updated equianalgesia tables and conversion rates for 17 different opioid formulations (of 9 different molecules) are presented as follows. Opioids remain the class that best suits clinical needs of emergency and post-operative medicine. However, it should be stressed that equianalgesia can be affected by drug-to-drug interactions and pharmacological imprecision, in a complex field where clinical experience may be the main guiding principle.


Assuntos
Analgésicos Opioides , Dor Crônica , Idoso , Analgésicos , Analgésicos Opioides/efeitos adversos , Criança , Dor Crônica/tratamento farmacológico , Feminino , Humanos , Manejo da Dor , Dor Pós-Operatória/tratamento farmacológico , Gravidez
2.
Eur J Ophthalmol ; 13(1): 49-56, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12635674

RESUMO

PURPOSE: To define a method for early detection of progressive visual field loss, based on monitoring the "healthy" component of the visual field, in glaucoma patients whose perimetric findings show the co-existence of deep scotomata and normal sensitivity areas. METHODS: We reviewed all the "central 30-2 threshold tests" stored in the oldest of our Humphrey perimeters (a 640 VFA model, in use at the Glaucoma Service of the University Eye Clinic of Genoa since 1986). Only the perimetric findings of glaucoma patients with pure, deep, localized defects were collected for this study. In accordance with several inclusion criteria, we could select only 12 series of consecutive examinations (12 eyes of 12 patients). Each series included 12 to 20 examinations and the observation period ranged from 6 years 2 months to 9 years 4 months. Some pre-defined criteria made it possible to separate the defective component of the visual field from the "healthy" one. Then two independent "mean deviations" were calculated, one related to the "healthy" area and one to the defective one. RESULTS: The mean deviation related to the "healthy" component of the visual field showed very little variation (0.6 to -1.3 dB) in the four series that had no increase in defects, even at the end of the observation period. However, in 7 of the 8 series with a tendency to worsen there was a small inter-test increase (-2.2 to -2.6 dB). This finding anticipated the enlargement of the scotomata, confirmed by subsequent examinations. Only in one series did the increase of the mean deviation related to the "healthy" area coincide in time with the real deterioration of the visual field, rather than anticipating it, but the inter-test interval had by chance been much longer than in the other series. The mean deviation related to the defective areas always showed very large changes in all the series, caused by the high variability of thresholds inside scotomata. This was the explanation for the large variations revealed by the "global" mean deviation too. CONCLUSIONS: Detecting progression is still one of the major problems in evaluating perimetric results. It might be easier to achieve this goal with a method for selectively monitoring light sensitivity inside the "healthy" areas of the visual field.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Escotoma/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais , Progressão da Doença , Glaucoma de Ângulo Aberto/complicações , Humanos , Reprodutibilidade dos Testes , Escotoma/etiologia , Sensibilidade e Especificidade
8.
Rev. argent. cir. plást ; 5(1): 66-9, ene. 1999. ilus
Artigo em Espanhol | BINACIS | ID: bin-15007

RESUMO

En el presente trabajo se enuncian pautas de tratamiento quirúrgico y de seguimiento de los carcinomas basocelulares de la piel. Para tales efectos se utiliza fundamentalmente la clasificación histológica del Dr. Jorge Abulafia, cuyos conceptos dividen a los mencionaados epiteliomas basocelulares en siete diferentes entidades que se describen. Se establece un protocolo general o conducta de tratamiento para estas afecciones encarando la cirugía resectiva y la eventual reparación posterior


Assuntos
Humanos , Adulto , Pele/cirurgia , Carcinoma Basocelular/cirurgia , Carcinoma Basocelular/história , Histologia/classificação
9.
Rev. argent. cir. plást ; 5(1): 66-9, 1999. ilus
Artigo em Espanhol | LILACS | ID: lil-243196

RESUMO

En el presente trabajo se enuncian pautas de tratamiento quirúrgico y de seguimiento de los carcinomas basocelulares de la piel. Para tales efectos se utiliza fundamentalmente la clasificación histológica del Dr. Jorge Abulafia, cuyos conceptos dividen a los mencionaados epiteliomas basocelulares en siete diferentes entidades que se describen. Se establece un protocolo general o conducta de tratamiento para estas afecciones encarando la cirugía resectiva y la eventual reparación posterior


Assuntos
Humanos , Adulto , Carcinoma Basocelular/história , Carcinoma Basocelular/cirurgia , Histologia/classificação , Pele/cirurgia
10.
Ophthalmology ; 104(4): 653-8, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9111259

RESUMO

PURPOSE: Color Doppler imaging (CDI) is a relatively new technique that allows quantification of blood flow velocity in orbital and ocular vasculature. Despite the numerous clinical studies that have used CDI, repeatability of this technique and agreement between observers have not been documented. METHODS: The authors performed a prospective investigation of the repeatability and agreement between observers on ophthalmic artery blood flow velocity measurements in 35 patients (35 eyes). RESULTS: Results on the estimated error of measurement (variability between repeated readings on the same subject) indicate good repeatability of the measurements; in fact, the measurement variances were only 5.6% for the peak systolic velocity, 11.4% for the end diastolic velocity, and 6.2% for the mean envelope velocity. The statistical analysis of repeatability showed a very narrow 95% confidence interval for both observers. The measurement of agreement between the two observers demonstrated the existence of a good concordance of the measurements taken by each observer on each subject. CONCLUSIONS: Results suggest that CDI is a reliable tool for quantitative assessment of ophthalmic artery blood flow velocity.


Assuntos
Velocidade do Fluxo Sanguíneo , Artéria Oftálmica/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
11.
Eur J Ophthalmol ; 6(4): 408-14, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8997584

RESUMO

PURPOSE: The aim of the study was to assess the presence and the importance of stato-kinetic dissociation (SKD) in subjects with normal and pathological visual fields (VF). METHODS: A "customized" perimetric test designed for the assessment of SKD was carried out in seven homogeneous samples of subjects (normal, glaucomatous, ocular hypertensive, retinopathic, cataract, anterior visual pathways neuropathic and posterior visual pathways neuropathic). The results were statistically compared (Anova). RESULTS AND CONCLUSIONS: SKD is a physiological phenomenon, more evident in the central, paracentral and superior VF, influenced by age and partially by sex. SKD increases in the VF periphery when a posterior visual pathway disorder or retinopathy is present, and decreases in the centro-paracentral VF of glaucomatous and ocular hypertensive eyes. This SKD behaviour should be useful for early diagnosis of glaucoma.


Assuntos
Percepção de Movimento/fisiologia , Transtornos da Visão/fisiopatologia , Testes de Campo Visual/métodos , Campos Visuais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/complicações , Catarata/diagnóstico , Catarata/fisiopatologia , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/fisiopatologia , Glaucoma/complicações , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Humanos , Cinética , Pessoa de Meia-Idade , Hipertensão Ocular/complicações , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Doenças do Nervo Óptico/complicações , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia , Limiar Sensorial , Transtornos da Visão/etiologia
12.
Eur J Ophthalmol ; 6(2): 201-7, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8823598

RESUMO

To evaluate amblyopic scotoma and the most affected neural cells in suppressive phenomena, eight patients with deep amblyopia from strabismus (visual acuity of the amblyopic eye between 4/50 and 2/10) underwent a pattern electroretinogram (PERG), pattern visual evoked potential (VEP), and event-related potential (ERP) from visual stimuli, and computerized perimetry. The results of stimulation of the amblyopic eye, the leading eye and the leading eye penalized by Ryser filters were compared statistically. Computerized perimetry was used to quantify the depth and amplitude of the amblyopic scotoma. All electrophysiological potentials were reduced in amplitude and the implicit times of VEP and ERP were longer when stimulating the amblyopic eye compared to the leading eye. Only in PERG the penalization induced major changes. Our data suggest that the important suppressive phenomena present in the squint amblyopic eye involve not only the occipital cortex, but also the cognitive areas.


Assuntos
Ambliopia/fisiopatologia , Potenciais Evocados Visuais/fisiologia , Escotoma/fisiopatologia , Estrabismo/complicações , Testes de Campo Visual/métodos , Adolescente , Adulto , Ambliopia/etiologia , Criança , Eletrorretinografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Escotoma/etiologia , Estrabismo/fisiopatologia , Acuidade Visual , Campos Visuais
13.
Curr Opin Ophthalmol ; 7(2): 65-71, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10163325

RESUMO

The glaucomas in pseudophakia are not uncommon. Because they can be related to different mechanisms, each case should be evaluated individually. Once glaucoma has been established and medication fails to maintain the intraocular pressure at a safe level, several options are available. As a group, the glaucomas are considered both difficult to manage with medications and also at high risk for failure of filtration surgery. Trabeculectomy adjuvated with anti-metabolites, draining implants, and cyclodestructive procedures are all effective procedures. Although complications and loss of vision as a consequence of glaucoma surgery are not frequent, they were reported by several authors. The likelihood of any given treatment to preserve the quality of life should be discussed with each patient and should be part of the decision-making process. This article reviews studies on the glaucomas in pseudophakia published from October 1994 to September 1995.


Assuntos
Extração de Catarata/efeitos adversos , Glaucoma/etiologia , Lentes Intraoculares/efeitos adversos , Antimetabólitos/uso terapêutico , Glaucoma/fisiopatologia , Glaucoma/terapia , Humanos , Pressão Intraocular , Complicações Pós-Operatórias , Trabeculectomia
14.
Int Ophthalmol ; 20(1-3): 49-51, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9112163

RESUMO

PURPOSE: A randomized clinical, trial to assess ocular hypotensive effect of sublingual administration of timolol was performed. PATIENTS AND METHODS: Seventeen (9 male, 8 female; age range 45 to 68 years) with bilateral ocular hypertension were selected for the study. Each patient was evaluated with regard to IOP, arterial blood pressure and heart rate before and after each of the following experimental treatment: unilateral ocular administration of 20 microliters of 0.5% timolol solution; sublingual administration of 20 microliters of 0.5% timolol solution; unilateral ocular administration of 20 microliters of saline solution (placebo); sublingual administration of 20 microliters of saline solution (placebo). The sequence of the treatments and the eye topically treated were randomly chosen. At least four weeks wash-out elapsed between each experimental treatment. RESULTS: Our results showed that sublingual administration of timolol was able to induce a bilateral significant reduction of the IOP. This reduction was not statistically different from that obtained in the eye treated with timolol. A significantly greater reduction of the IOP was obtained by sublingual timolol than in the contralateral eye after unilateral topical administration of timolol solution. No significant modification of arterial blood pressure and heart rate were evidenced after the treatment. CONCLUSIONS: Sublingual administration seems to be a new interesting way for reducing the IOP. Long term studies are required in order to test efficacy and safety of this new treatment.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Hipertensão Ocular/tratamento farmacológico , Timolol/administração & dosagem , Administração Sublingual , Administração Tópica , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Pressão Sanguínea/efeitos dos fármacos , Estudos Cross-Over , Feminino , Seguimentos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Pressão Intraocular/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Soluções Oftálmicas , Estudos Prospectivos , Segurança , Timolol/uso terapêutico , Resultado do Tratamento
15.
J Med Eng Technol ; 19(2-3): 80-3, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7494215

RESUMO

Human visual-evoked potentials (VEPs) from upper and lower hemifield stimulation are thought to reflect the anatomical and functional differences between the hemiretinas and corresponding visual pathways. Conflicting results have, however, been reported in topographic studies on the putative cortical generators. We have estimated by automatic perimetry (Octopus 2000R, Program 32) and compared the sensitivity thresholds of lower and upper hemifields of the retina in 12 healthy subjects with no history or evidence of visual or neurological diseases. A visual P3 that is linked to cognitive function was recorded in an odd-ball paradigm with presentation of high-contrast checkerboards at two different spatial frequencies at 20 degrees eccentricity in each hemifield. VEP and P3 were recorded at O1 and O2 and at Cz according to the 10/20 international system. Lower sensitivity thresholds were found, and higher VEP and event-related potential (ERP) amplitude values were obtained when stimulating the lower, compared with the upper, visual hemifield. The results are consistent with previous findings and anatomical and physiological evidence in animals and man. Interactions between perceptive process in the visual system and higher cognitive functions are a possible explanation for this finding.


Assuntos
Potenciais Evocados P300 , Potenciais Evocados Visuais , Campos Visuais/fisiologia , Adulto , Cognição/fisiologia , Feminino , Humanos , Masculino , Tempo de Reação/fisiologia , Valores de Referência , Retina/fisiologia , Limiar Sensorial , Testes de Campo Visual , Percepção Visual/fisiologia
16.
Int Ophthalmol ; 18(4): 247-50, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7797391

RESUMO

In order to reduce corneal complications in 27 glaucomatous eyes that underwent trabeculectomy and postoperative subconjunctival injection of 5-fluorouracil we tried 1) a low-dose administration of 5-fluorouracil and 2) a modified subconjunctival injection technique. The mean total 5-fluorouracil dose was 18.0 +/- 6 mg. A life-table analysis showed a success rate, at 15 months, of 78% (+/- 7 S.E.). Four of the 27 eyes (13%) had corneal complications, limited to punctate keratopathy, with no corneal epithelial defects and/or abrasions. Our study shows that corneal complications decreased when the contact between 5-fluorouracil and the ocular surface was reduced.


Assuntos
Doenças da Córnea/prevenção & controle , Fluoruracila/administração & dosagem , Glaucoma/tratamento farmacológico , Glaucoma/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Trabeculectomia , Adolescente , Adulto , Idoso , Criança , Túnica Conjuntiva , Doenças da Córnea/induzido quimicamente , Fibrose/tratamento farmacológico , Fluoruracila/efeitos adversos , Humanos , Injeções , Pessoa de Meia-Idade , Complicações Pós-Operatórias/induzido quimicamente
17.
Int Ophthalmol ; 16(4-5): 363-5, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1428572

RESUMO

We have performed ab-externo photoablative filtration surgery on 19 patients affected by uncontrolled primary open-angle glaucoma. All cases had wide open angles, were previously treated with argon laser trabeculoplasty and were considered good candidates for trabeculectomy. After topical and peribulbar anesthesia, a limbus-based conjunctival flap was dissected. Photoablation of a rectangular area at the limbus was performed with an argon fluoride excimer laser (193 nm), at 180 mJ x sq cm fluence. The beam was shaped in the appropriate fashion using a custom-made metal mask. Photoablation was continued until aqueous appeared percolating through the juxtacanalicular tissue at the bottom of the crater; a water-tight closure of conjunctiva was then performed. Postoperatively, the anterior chamber reaction was minimal; in no case a flat chamber or choroidal detachment was observed. In 18 of the 19 cases the IOP was significantly lowered, and a filtering bleb developed. Mean preoperative IOP was 26.4 (+/- 7) mmHg. At a median follow-up of 9 months (range 4-15) the IOP is < or = 18 mmHg on no medications in 16 (84%) of the eyes, with a mean value of 13.3 (+/- 6) mmHg. Our short-term results support excimer laser photoablative filtration as a relatively safe and effective procedure for primary open-angle glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Fotocoagulação a Laser , Trabeculectomia , Idoso , Seguimentos , Humanos , Pressão Intraocular , Pessoa de Meia-Idade , Projetos Piloto , Complicações Pós-Operatórias , Estudos Prospectivos , Esclera/cirurgia , Retalhos Cirúrgicos
18.
Eur J Ophthalmol ; 1(4): 181-6, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1821212

RESUMO

A new automatic perimeter has recently been developed under the supervision of the Perimetry Study Group of the Genoa University Eye Clinic. The main characteristics of this instrument are the following: projected targets; accurate calibration of stimulus size and shape; preliminary measurement of visual acuity and pupillary diameter; automated fixation control based on an optimized television system; static, kinetic, and mixed procedures; screening and diagnostic threshold and suprathreshold strategies; standard and non-standard parameters for stimuli, background, and procedures; user-friendly software; large disk memory for data storage and analysis.


Assuntos
Diagnóstico por Computador , Testes de Campo Visual/instrumentação , Campos Visuais , Desenho de Equipamento , Humanos , Pupila/fisiologia , Software , Acuidade Visual/fisiologia
19.
Artigo em Inglês | MEDLINE | ID: mdl-2079905

RESUMO

The contribution given by manual perimetry to differential diagnosis of optic neuropathies is described. The advantages and the disadvantages of automated perimetry in respect to manual perimetry are examined. The programs to use for a more precise diagnosis and according to different pathology are also examined. The problems connected to perimetric interpretation are discussed. The value of global indices in evaluating the visual field as well as the importance of statistical program in comparing more than one test performed are reported. The review stresses the usefulness of automated perimetry in early diagnosis and in the follow up of optic nerve diseases.


Assuntos
Doenças do Nervo Óptico/diagnóstico , Testes de Campo Visual/métodos , Diagnóstico por Computador , Diagnóstico Diferencial , Humanos
20.
Acta Neurol Scand ; 76(4): 246-50, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3687374

RESUMO

The incidence of a delayed P100 component of the VEP after checkerboard stimulation in probable or possible multiple sclerosis (MS) without history, signs or symptoms of optic neuritis is not significantly different from that found in other neurological disorders in which the visual system is unaffected. This reduces the diagnostic validity of a delayed P100 as evidence of "silent" plaques in the optic pathway, at least in suspected MS. The use of grating increases the VEP sensitivity in the MS group, but it still leaves more than a 30% chance of error in attributing a delayed P100 to a demyelinating disorder. In this respect the discordant behaviour of checkerboard and grating responses may represent a useful clue.


Assuntos
Potenciais Evocados Visuais , Esclerose Múltipla/fisiopatologia , Doenças do Nervo Óptico/diagnóstico , Adulto , Humanos , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA