Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38293030

RESUMO

Modular organization is fundamental to cortical processing, but its presence is human association cortex is unknown. We characterized phoneme processing with 128-1024 channel micro-arrays at 50-200µm pitch on superior temporal gyrus of 7 patients. High gamma responses were highly correlated within ~1.7mm diameter modules, sharply delineated from adjacent modules with distinct time-courses and phoneme-selectivity. We suggest that receptive language cortex may be organized in discrete processing modules.

2.
J Neurosurg ; 140(3): 665-676, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37874692

RESUMO

OBJECTIVE: The study objective was to evaluate intraoperative experience with newly developed high-spatial-resolution microelectrode grids composed of poly(3,4-ethylenedioxythiophene) with polystyrene sulfonate (PEDOT:PSS), and those composed of platinum nanorods (PtNRs). METHODS: A cohort of patients who underwent craniotomy for pathological tissue resection and who had high-spatial-resolution microelectrode grids placed intraoperatively were evaluated. Patient demographic and baseline clinical variables as well as relevant microelectrode grid characteristic data were collected. The primary and secondary outcome measures of interest were successful microelectrode grid utilization with usable resting-state or task-related data, and grid-related adverse intraoperative events and/or grid dysfunction. RESULTS: Included in the analysis were 89 cases of patients who underwent a craniotomy for resection of neoplasms (n = 58) or epileptogenic tissue (n = 31). These cases accounted for 94 grids: 58 PEDOT:PSS and 36 PtNR grids. Of these 94 grids, 86 were functional and used successfully to obtain cortical recordings from 82 patients. The mean cortical grid recording duration was 15.3 ± 1.15 minutes. Most recordings in patients were obtained during experimental tasks (n = 52, 58.4%), involving language and sensorimotor testing paradigms, or were obtained passively during resting state (n = 32, 36.0%). There were no intraoperative adverse events related to grid placement. However, there were instances of PtNR grid dysfunction (n = 8) related to damage incurred by suboptimal preoperative sterilization (n = 7) and improper handling (n = 1); intraoperative recordings were not performed. Vaporized peroxide sterilization was the most optimal sterilization method for PtNR grids, providing a significantly greater number of usable channels poststerilization than did steam-based sterilization techniques (median 905.0 [IQR 650.8-935.5] vs 356.0 [IQR 18.0-597.8], p = 0.0031). CONCLUSIONS: High-spatial-resolution microelectrode grids can be readily incorporated into appropriately selected craniotomy cases for clinical and research purposes. Grids are reliable when preoperative handling and sterilization considerations are accounted for. Future investigations should compare the diagnostic utility of these high-resolution grids to commercially available counterparts and assess whether diagnostic discrepancies relate to clinical outcomes.


Assuntos
Sistemas Computacionais , Craniotomia , Humanos , Microeletrodos , Idioma , Peróxidos
3.
Sci Transl Med ; 14(628): eabj1441, 2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-35044788

RESUMO

Electrophysiological devices are critical for mapping eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively used for research in brain-machine interfaces. However, the existing clinical and experimental devices are often limited in either spatial resolution or cortical coverage. Here, we developed scalable manufacturing processes with a dense electrical connection scheme to achieve reconfigurable thin-film, multithousand-channel neurophysiological recording grids using platinum nanorods (PtNRGrids). With PtNRGrids, we have achieved a multithousand-channel array of small (30 µm) contacts with low impedance, providing high spatial and temporal resolution over a large cortical area. We demonstrated that PtNRGrids can resolve submillimeter functional organization of the barrel cortex in anesthetized rats that captured the tissue structure. In the clinical setting, PtNRGrids resolved fine, complex temporal dynamics from the cortical surface in an awake human patient performing grasping tasks. In addition, the PtNRGrids identified the spatial spread and dynamics of epileptic discharges in a patient undergoing epilepsy surgery at 1-mm spatial resolution, including activity induced by direct electrical stimulation. Collectively, these findings demonstrated the power of the PtNRGrids to transform clinical mapping and research with brain-machine interfaces.


Assuntos
Mapeamento Encefálico , Epilepsia , Animais , Encéfalo/fisiologia , Estimulação Elétrica , Humanos , Ratos , Vigília
4.
Clin Neurophysiol ; 132(11): 2916-2931, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34419344

RESUMO

OBJECTIVE: Interictal discharges (IIDs) and high frequency oscillations (HFOs) are established neurophysiologic biomarkers of epilepsy, while microseizures are less well studied. We used custom poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) microelectrodes to better understand these markers' microscale spatial dynamics. METHODS: Electrodes with spatial resolution down to 50 µm were used to record intraoperatively in 30 subjects. IIDs' degree of spread and spatiotemporal paths were generated by peak-tracking followed by clustering. Repeating HFO patterns were delineated by clustering similar time windows. Multi-unit activity (MUA) was analyzed in relation to IID and HFO timing. RESULTS: We detected IIDs encompassing the entire array in 93% of subjects, while localized IIDs, observed across < 50% of channels, were seen in 53%. IIDs traveled along specific paths. HFOs appeared in small, repeated spatiotemporal patterns. Finally, we identified microseizure events that spanned 50-100 µm. HFOs covaried with MUA, but not with IIDs. CONCLUSIONS: Overall, these data suggest that irritable cortex micro-domains may form part of an underlying pathologic architecture which could contribute to the seizure network. SIGNIFICANCE: These results, supporting the possibility that epileptogenic cortex comprises a mosaic of irritable domains, suggests that microscale approaches might be an important perspective in devising novel seizure control therapies.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiopatologia , Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Monitorização Neurofisiológica Intraoperatória/métodos , Microeletrodos , Adulto , Encéfalo/cirurgia , Eletroencefalografia/instrumentação , Epilepsia/diagnóstico , Epilepsia/cirurgia , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Cereb Cortex ; 31(8): 3678-3700, 2021 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-33749727

RESUMO

Despite ongoing advances in our understanding of local single-cellular and network-level activity of neuronal populations in the human brain, extraordinarily little is known about their "intermediate" microscale local circuit dynamics. Here, we utilized ultra-high-density microelectrode arrays and a rare opportunity to perform intracranial recordings across multiple cortical areas in human participants to discover three distinct classes of cortical activity that are not locked to ongoing natural brain rhythmic activity. The first included fast waveforms similar to extracellular single-unit activity. The other two types were discrete events with slower waveform dynamics and were found preferentially in upper cortical layers. These second and third types were also observed in rodents, nonhuman primates, and semi-chronic recordings from humans via laminar and Utah array microelectrodes. The rates of all three events were selectively modulated by auditory and electrical stimuli, pharmacological manipulation, and cold saline application and had small causal co-occurrences. These results suggest that the proper combination of high-resolution microelectrodes and analytic techniques can capture neuronal dynamics that lay between somatic action potentials and aggregate population activity. Understanding intermediate microscale dynamics in relation to single-cell and network dynamics may reveal important details about activity in the full cortical circuit.


Assuntos
Córtex Cerebral/fisiologia , Neurônios/fisiologia , Estimulação Acústica , Adulto , Animais , Estimulação Elétrica , Eletroencefalografia , Fenômenos Eletrofisiológicos , Epilepsia/fisiopatologia , Espaço Extracelular/fisiologia , Feminino , Humanos , Macaca mulatta , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos ICR , Microeletrodos , Pessoa de Meia-Idade , Córtex Somatossensorial/fisiologia , Análise de Ondaletas , Adulto Jovem
6.
J Neural Eng ; 17(5): 056036, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32998116

RESUMO

OBJECTIVE: Electrical stimulation via microelectrodes implanted in cortex has been suggested as a potential treatment for a wide range of neurological disorders. Despite some success however, the effectiveness of conventional electrodes remains limited, in part due to an inability to create specific patterns of neural activity around each electrode and in part due to challenges with maintaining a stable interface. The use of implantable micro-coils to magnetically stimulate the cortex has the potential to overcome these limitations because the asymmetric fields from coils can be harnessed to selectively activate some neurons, e.g. vertically-oriented pyramidal neurons while avoiding others, e.g. horizontally-oriented passing axons. In vitro experiments have shown that activation is indeed confined with micro-coils but their effectiveness in the intact brain of living animals has not been evaluated. APPROACH: To assess the efficacy of stimulation, a 128-channel custom recording microelectrode array was positioned on the surface of the visual cortex (ECoG) in anesthetized mice and responses to magnetic and electric stimulation were compared. Stimulation was delivered from electrodes or micro-coils implanted through a hole in the center of the recording array at a rate of 200 pulses per second for 100 ms. MAIN RESULTS: Both electric and magnetic stimulation reliably elicited cortical responses, although activation from electric stimulation was spatially expansive, often extending more than 1 mm from the stimulation site, while activation from magnetic stimulation was typically confined to a ∼300 µm diameter region around the stimulation site. Results were consistent for stimulation of both cortical layer 2/3 and layer 5 as well as across a range of stimulus strengths. SIGNIFICANCE: The improved focality with magnetic stimulation suggests that the effectiveness of cortical stimulation can be improved. Improved focality may be particularly attractive for cortical prostheses that require high spatial resolution, e.g. devices that target sensory cortex, as it may lead to improved acuity.


Assuntos
Córtex Visual , Animais , Estimulação Elétrica , Eletrodos Implantados , Fenômenos Magnéticos , Camundongos , Microeletrodos , Neurônios
7.
iScience ; 23(8): 101387, 2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32745989

RESUMO

Implanted electrodes provide one of the most important neurotechniques for fundamental and translational neurosciences by permitting time-resolved electrical detection of individual neurons in vivo. However, conventional rigid electrodes typically cannot provide stable, long-lasting recordings. Numerous interwoven biotic and abiotic factors at the tissue-electrode interface lead to short- and long-term instability of the recording performance. Making neural electrodes flexible provides a promising approach to mitigate these challenges on the implants and at the tissue-electrode interface. Here we review the recent progress of ultraflexible neural electrodes and discuss the engineering principles, the material properties, and the implantation strategies to achieve stable tissue-electrode interface and reliable unit recordings in living brains.

8.
Front Neurosci ; 14: 55, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32180695

RESUMO

High-fidelity measurements of neural activity can enable advancements in our understanding of the neural basis of complex behaviors such as speech, audition, and language, and are critical for developing neural prostheses that address impairments to these abilities due to disease or injury. We develop a novel high resolution, thin-film micro-electrocorticography (micro-ECoG) array that enables high-fidelity surface measurements of neural activity from songbirds, a well-established animal model for studying speech behavior. With this device, we provide the first demonstration of sensory-evoked modulation of surface-recorded single unit responses. We establish that single unit activity is consistently sensed from micro-ECoG electrodes over the surface of sensorimotor nucleus HVC (used as a proper name) in anesthetized European starlings, and validate responses with correlated firing in single units recorded simultaneously at surface and depth. The results establish a platform for high-fidelity recording from the surface of subcortical structures that will accelerate neurophysiological studies, and development of novel electrode arrays and neural prostheses.

9.
Nano Lett ; 19(9): 6244-6254, 2019 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-31369283

RESUMO

The enhanced electrochemical activity of nanostructured materials is readily exploited in energy devices, but their utility in scalable and human-compatible implantable neural interfaces can significantly advance the performance of clinical and research electrodes. We utilize low-temperature selective dealloying to develop scalable and biocompatible one-dimensional platinum nanorod (PtNR) arrays that exhibit superb electrochemical properties at various length scales, stability, and biocompatibility for high performance neurotechnologies. PtNR arrays record brain activity with cellular resolution from the cortical surfaces in birds and nonhuman primates. Significantly, strong modulation of surface recorded single unit activity by auditory stimuli is demonstrated in European Starling birds as well as the modulation of local field potentials in the visual cortex by light stimuli in a nonhuman primate and responses to electrical stimulation in mice. PtNRs record behaviorally and physiologically relevant neuronal dynamics from the surface of the brain with high spatiotemporal resolution, which paves the way for less invasive brain-machine interfaces.


Assuntos
Potenciais de Ação , Materiais Biocompatíveis , Interfaces Cérebro-Computador , Nanotubos , Neurônios/metabolismo , Platina , Córtex Visual/fisiologia , Animais , Estimulação Elétrica , Eletrodos , Macaca mulatta , Masculino , Camundongos , Aves Canoras
10.
PLoS Comput Biol ; 15(2): e1006769, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30742605

RESUMO

Electrocorticography (ECoG) is becoming more prevalent due to improvements in fabrication and recording technology as well as its ease of implantation compared to intracortical electrophysiology, larger cortical coverage, and potential advantages for use in long term chronic implantation. Given the flexibility in the design of ECoG grids, which is only increasing, it remains an open question what geometry of the electrodes is optimal for an application. Conductive polymer, PEDOT:PSS, coated microelectrodes have an advantage that they can be made very small without losing low impedance. This makes them suitable for evaluating the required granularity of ECoG recording in humans and experimental animals. We used two-dimensional (2D) micro-ECoG grids to record intra-operatively in humans and during acute implantations in mouse with separation distance between neighboring electrodes (i.e., pitch) of 0.4 mm and 0.2/0.25 mm respectively. To assess the spatial properties of the signals, we used the average correlation between electrodes as a function of the pitch. In agreement with prior studies, we find a strong frequency dependence in the spatial scale of correlation. By applying independent component analysis (ICA), we find that the spatial pattern of correlation is largely due to contributions from multiple spatially extended, time-locked sources present at any given time. Our analysis indicates the presence of spatially structured activity down to the sub-millimeter spatial scale in ECoG despite the effects of volume conduction, justifying the use of dense micro-ECoG grids.


Assuntos
Eletrocorticografia/métodos , Animais , Interfaces Cérebro-Computador , Córtex Cerebral , Condutividade Elétrica , Eletrodos Implantados , Eletroencefalografia/métodos , Fenômenos Eletrofisiológicos , Humanos , Camundongos , Microeletrodos , Polímeros , Registros
11.
Adv Healthc Mater ; 7(22): e1800923, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30369088

RESUMO

Poly(3,4-ethylenenedioxythiophene) or PEDOT is a promising candidate for next-generation neuronal electrode materials but its weak adhesion to underlying metallic conductors impedes its potential. An effective method of mechanically anchoring the PEDOT within an Au nanorod (Au-nr) structure is reported and it is demonstrated that it provides enhanced adhesion and overall PEDOT layer stability. Cyclic voltammetry (CV) stress is used to investigate adhesion and stability of spin-cast and electrodeposited PEDOT. The Au-nr adhesion layer permits 10 000 CV cycles of coated PEDOT film in phosphate buffered saline solution without delamination nor significant change of the electrochemical impedance, whereas PEDOT coating film on planar Au electrodes delaminates at or below 1000 cycles. Under CV stress, spin-cast PEDOT on planar Au delaminates, whereas electroplated PEDOT on planar Au encounters surface leaching/decomposition. After 5 weeks of accelerated aging tests at 60 °C, the electrodeposited PEDOT/Au-nr microelectrodes demonstrate a 92% channel survival compared to only 25% survival for spin-cast PEDOT on planar films. Furthermore, after a 10 week chronic implantation onto mouse barrel cortex, PEDOT/Au-nr microelectrodes do not exhibit delamination nor morphological changes, whereas the conventional PEDOT microelectrodes either partially or fully delaminate. Immunohistochemical evaluation demonstrates no or minimal response to the PEDOT implant.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Ouro/química , Nanotubos/química , Neurônios/fisiologia , Polímeros/química , Animais , Encéfalo/patologia , Eletrodos Implantados , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Aderências Teciduais
12.
Neuroimage ; 176: 454-464, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29678760

RESUMO

Electrocorticography (ECoG), electrophysiological recording from the pial surface of the brain, is a critical measurement technique for clinical neurophysiology, basic neurophysiology studies, and demonstrates great promise for the development of neural prosthetic devices for assistive applications and the treatment of neurological disorders. Recent advances in device engineering are poised to enable orders of magnitude increase in the resolution of ECoG without comprised measurement quality. This enhancement in cortical sensing enables the observation of neural dynamics from the cortical surface at the micrometer scale. While these technical capabilities may be enabling, the extent to which finer spatial scale recording enhances functionally relevant neural state inference is unclear. We examine this question by employing a high-density and low impedance 400 µm pitch microECoG (µECoG) grid to record neural activity from the human cortical surface during cognitive tasks. By applying machine learning techniques to classify task conditions from the envelope of high-frequency band (70-170Hz) neural activity collected from two study participants, we demonstrate that higher density grids can lead to more accurate binary task condition classification. When controlling for grid area and selecting task informative sub-regions of the complete grid, we observed a consistent increase in mean classification accuracy with higher grid density; in particular, 400 µm pitch grids outperforming spatially sub-sampled lower density grids up to 23%. We also introduce a modeling framework to provide intuition for how spatial properties of measurements affect the performance gap between high and low density grids. To our knowledge, this work is the first quantitative demonstration of human sub-millimeter pitch cortical surface recording yielding higher-fidelity state estimation relative to devices at the millimeter-scale, motivating the development and testing of µECoG for basic and clinical neurophysiology as well as towards the realization of high-performance neural prostheses.


Assuntos
Córtex Cerebral/fisiologia , Eletrocorticografia , Processamento de Imagem Assistida por Computador/métodos , Idioma , Aprendizado de Máquina , Modelos Teóricos , Adulto , Córtex Cerebral/diagnóstico por imagem , Eletrocorticografia/instrumentação , Eletrocorticografia/métodos , Eletrocorticografia/normas , Eletrodos Implantados , Humanos , Processamento de Imagem Assistida por Computador/normas , Microeletrodos , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/fisiologia
13.
Adv Healthc Mater ; 5(24): 3094-3098, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27885829

RESUMO

Autoclaving, the most widely available sterilization method, is applied to poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) electrophysiology devices. The process does not harm morphology or electrical properties, while it effectively kills E. coli intentionally cultured on the devices. This finding paves the way to widespread introduction of PEDOT:PSS electrophysiology devices to the clinic.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Polímeros/química , Poliestirenos/química , Eletrofisiologia/métodos , Escherichia coli/química , Escherichia coli/crescimento & desenvolvimento , Esterilização/métodos
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 4511-4514, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28325009

RESUMO

Open source electrophysiology (ephys) recording systems have several advantages over commercial systems such as customization and affordability enabling more researchers to conduct ephys experiments. Notable open source ephys systems include Open-Ephys, NeuroRighter and more recently Willow, all of which have high channel count (64+), scalability, and advanced software to develop on top of. However, little work has been done to build an open source ephys system that is clinic compatible, particularly in the operating room where acute human electrocorticography (ECoG) research is performed. We developed an affordable (<; $10,000) and open system for research purposes that features power isolation for patient safety, compact and water resistant enclosures and 256 recording channels sampled up to 20ksam/sec, 16-bit. The system was validated by recording ECoG with a high density, thin film device for an acute, awake craniotomy study at UC San Diego, Thornton Hospital Operating Room.


Assuntos
Coleta de Dados/instrumentação , Eletrocorticografia/instrumentação , Eletrofisiologia/instrumentação , Software , Adulto , Craniotomia , Humanos , Masculino , Vigília
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...