Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 8948, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268642

RESUMO

In recent years, transcatheter aortic valve replacement (TAVR) has become the leading method for treating aortic stenosis. While the procedure has improved dramatically in the past decade, there are still uncertainties about the impact of TAVR on coronary blood flow. Recent research has indicated that negative coronary events after TAVR may be partially driven by impaired coronary blood flow dynamics. Furthermore, the current technologies to rapidly obtain non-invasive coronary blood flow data are relatively limited. Herein, we present a lumped parameter computational model to simulate coronary blood flow in the main arteries as well as a series of cardiovascular hemodynamic metrics. The model was designed to only use a few inputs parameters from echocardiography, computed tomography and a sphygmomanometer. The novel computational model was then validated and applied to 19 patients undergoing TAVR to examine the impact of the procedure on coronary blood flow in the left anterior descending (LAD) artery, left circumflex (LCX) artery and right coronary artery (RCA) and various global hemodynamics metrics. Based on our findings, the changes in coronary blood flow after TAVR varied and were subject specific (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). Additionally, valvular pressure gradient, left ventricle (LV) workload and maximum LV pressure decreased by 61.5%, 4.5% and 13.0% respectively, while mean arterial pressure and cardiac output increased by 6.9% and 9.9% after TAVR. By applying this proof-of-concept computational model, a series of hemodynamic metrics were generated non-invasively which can help to better understand the individual relationships between TAVR and mean and peak coronary flow rates. In the future, tools such as these may play a vital role by providing clinicians with rapid insight into various cardiac and coronary metrics, rendering the planning for TAVR and other cardiovascular procedures more personalized.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
2.
J Am Heart Assoc ; 12(11): e029310, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37232234

RESUMO

Background Despite the proven benefits of transcatheter aortic valve replacement (TAVR) and its recent expansion toward the whole risk spectrum, coronary artery disease is present in more than half of the candidates for TAVR. Many previous studies do not focus on the longer-term impact of TAVR on coronary arteries, and hemodynamic changes to the circulatory system in response to the anatomical changes caused by TAVR are not fully understood. Methods and Results We developed a multiscale patient-specific computational framework to examine the effect of TAVR on coronary and cardiac hemodynamics noninvasively. Based on our findings, TAVR might have an adverse impact on coronary hemodynamics due to the lack of sufficient coronary blood flow during diastole phase (eg, maximum coronary flow rate reduced by 8.98%, 16.83%, and 22.73% in the left anterior descending, left circumflex coronary artery, and right coronary artery, respectively [N=31]). Moreover, TAVR may increase the left ventricle workload (eg, left ventricle workload increased by 2.52% [N=31]) and decrease the coronary wall shear stress (eg, maximum time averaged wall shear stress reduced by 9.47%, 7.75%, 6.94%, 8.07%, and 6.28% for bifurcation, left main coronary artery, left anterior descending, left circumflex coronary artery, and right coronary artery branches, respectively). Conclusions The transvalvular pressure gradient relief after TAVR might not result in coronary flow improvement and reduced cardiac load. Optimal revascularization strategy pre-TAVR and progression of coronary artery disease after TAVR could be determined by noninvasive personalized computational modeling.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Hemodinâmica , Fatores de Risco
3.
IEEE Rev Biomed Eng ; 16: 403-423, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35015648

RESUMO

Cardiovascular disease is a deadly global health crisis that carries a substantial financial burden. Innovative treatment and management of cardiovascular disease straddles medicine, personalized hemodynamic modeling, machine learning, and modern imaging to help improve patient outcomes and reduce the economic impact. Hemodynamic modeling offers a non-invasive method to provide clinicians with new pre- and post- procedural metrics and aid in the selection of treatment options. Medical imaging is an integral part in clinical workflows for understanding and managing cardiac disease and interventions. Coupling machine learning with modeling, and cardiovascular imaging, provides faster modeling, improved data fidelity, and an enhanced understanding and earlier detection of cardiovascular anomalies, leading to the development of patient-specific diagnostic and predictive tools for characterizing and assessing cardiovascular outcomes. Herein, we provide a scoping review of translational hemodynamic modeling, medical imaging, and machine learning and their applications to cardiovascular interventions. We particularly focus on providing an intuitive understanding of each of these approaches and their ability to support decision making during important clinical milestones.


Assuntos
Doenças Cardiovasculares , Cardiopatias , Humanos , Diagnóstico por Imagem , Aprendizado de Máquina , Radiografia
4.
Sci Rep ; 12(1): 21357, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494362

RESUMO

Transcatheter aortic valve replacement (TAVR) is a frequently used minimally invasive intervention for patient with aortic stenosis across a broad risk spectrum. While coronary artery disease (CAD) is present in approximately half of TAVR candidates, correlation of post-TAVR complications such as paravalvular leakage (PVL) or misalignment with CAD are not fully understood. For this purpose, we developed a multiscale computational framework based on a patient-specific lumped-parameter algorithm and a 3-D strongly-coupled fluid-structure interaction model to quantify metrics of global circulatory function, metrics of global cardiac function and local cardiac fluid dynamics in 6 patients. Based on our findings, PVL limits the benefits of TAVR and restricts coronary perfusion due to the lack of sufficient coronary blood flow during diastole phase (e.g., maximum coronary flow rate reduced by 21.73%, 21.43% and 21.43% in the left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)). Moreover, PVL may increase the LV load (e.g., LV load increased by 17.57% (N = 6)) and decrease the coronary wall shear stress (e.g., maximum wall shear stress reduced by 20.62%, 21.92%, 22.28% and 25.66% in the left main coronary artery (LMCA), left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)), which could promote atherosclerosis development through loss of the physiological flow-oriented alignment of endothelial cells. This study demonstrated that a rigorously developed personalized image-based computational framework can provide vital insights into underlying mechanics of TAVR and CAD interactions and assist in treatment planning and patient risk stratification in patients.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/etiologia , Prognóstico , Células Endoteliais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hemodinâmica , Vasos Coronários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...