Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 153: 106479, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492502

RESUMO

In this paper, we introduce the design and manufacturing process of a transtibial orthopedic implant. We used medical-grade polyurethane polymer resin to fabricate a 3D porous architected implant with tunable isotropy, employing a high-speed printing method known as Continuous Liquid Interface Production (CLIP). Our objective is to enhance the weight-bearing capabilities of the bone structures in the residual limb, thereby circumventing the traditional reliance on a natural bridge. To achieve a custom-made design, we acquire the topology and morphology of the residual limb as well as the bone structure of the tibia and fibula, utilizing computed tomography (CT) and high-resolution 3D scanning. We employed a dynamic topological optimization method, informed by gait cycle data, to effectively reduce the mass of the implant. This approach, which differs from conventional static methods, enables the quantification of variations in applied forces over time. Using the Euler-Lagrange energy approach, we propose the equations of motion for a homologous multibody model with three degrees of freedom. The versatility of the Solid Isotropic Material with Penalization (SIMP) method facilitates the integration of homogenization methods for microscale porous architectures into the optimized domain. The design of these porous architectures is based on a bias-driven tuning symmetry isotropy of a Triply Periodic Minimal Surface (Schwarz Primitive surface). The internal porosity of the structure significantly reduces weight without compromising the isotropic behavior of the implant.


Assuntos
Polímeros , Próteses e Implantes , Porosidade , Osso e Ossos , Impressão Tridimensional
2.
Polymers (Basel) ; 16(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276692

RESUMO

The dip coating process is one of the recognized techniques used to generate polymeric coatings on stents in an easy and low-cost way. However, there is a lack of information about the influence of the process parameters of this technique on complex geometries such as stents. This paper studies the dip coating process parameters used to provide a uniform coating of PLA with a 4-10 µm thickness. A stainless-steel tube (AISI 316L) was laser-cut, electropolished, and dip-coated in a polylactic acid (PLA) solution whilst changing the process parameters. The samples were characterized to examine the coating's uniformity, thickness, surface roughness, weight, and chemical composition. FTIR and Raman investigations indicated the presence of PLA on the stent's surface, the chemical stability of PLA during the coating process, and the absence of residual chloroform in the coatings. Additionally, the water contact angle was measured to determine the hydrophilicity of the coating. Our results indicate that, when using entry and withdrawal speeds of 500 mm min-1 and a 15 s immersion time, a uniform coating thickness was achieved throughout the tube and in the stent with an average thickness of 7.8 µm.

3.
Materials (Basel) ; 16(3)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36770032

RESUMO

The growth of additive manufacturing processes has enabled the production of complex and smart structures. These fabrication techniques have led research efforts to focus on the application of cellular materials, which are known for their thermal and mechanical benefits. Herein, we studied the mechanical behavior of stainless-steel (AISI 316L) lattice structures both experimentally and computationally. The lattice architectures were body-centered cubic, hexagonal vertex centroid, and tetrahedron in two cell sizes and at two different rotation angles. A preliminary computational study assessed the deformation behavior of porous cylindrical samples under compression. After the simulation results, selected samples were manufactured via laser powder bed fusion. The results showed the effects of the pore architecture, unit cell size, and orientation on the reduction in the mechanical properties. The relative densities between 23% and 69% showed a decrease in the bulk material stiffness up to 93%. Furthermore, the different rotation angles resulted in a similar porosity level but different stiffnesses. The simulation analysis and experimental results indicate that the variation in the strut position with respect to the force affected the deformation mechanism. The tetrahedron unit cell showed the smallest variation in the elastic modulus and off-axis displacements due to the cell orientation. This study collected computational and experimental data for tuning the mechanical properties of lattice structures by changing the geometry, size, and orientation of the unit cell.

4.
Materials (Basel) ; 15(1)2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-35009246

RESUMO

A novel manufacturing approach was used to fabricate metallic scaffolds. A calibration of the laser cutting process was performed using the kerf width compensation in the calculations of the tool trajectory. Welding defects were studied through X-ray microtomography. Penetration depth and width resulted in relative errors of 9.4%, 1.0%, respectively. Microhardness was also measured, and the microstructure was studied in the base material. The microhardness values obtained were 400 HV, 237 HV, and 215 HV for the base material, HAZ, and fusion zone, respectively. No significant difference was found between the microhardness measurement along with different height positions of the scaffold. The scaffolds' dimensions and porosity were measured, their internal architecture was observed with micro-computed tomography. The results indicated that geometries with dimensions under 500 µm with different shapes resulted in relative errors of ~2.7%. The fabricated scaffolds presented an average compressive modulus ~13.15 GPa, which is close to cortical bone properties. The proposed methodology showed a promising future in bone tissue engineering applications.

5.
Materials (Basel) ; 13(22)2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33213110

RESUMO

The interplay between a prosthetic and tissue represents an important factor for the fixation of orthopedic implants. Laser texturing tests and electropolishing were performed on two materials used in the fabrication of medical devices, i.e., CoCr and Ti6Al4V-ELI alloys. The material surface was textured with a diode-pumped solid state (DPSS) laser and its effect on the surface quality and material modification, under different combinations of laser power and marking speed, were investigated. Our results indicate that an increment of energy per unit length causes an incremental trend in surface roughness parameters. Additionally, phase transformation on the surface of both alloys was achieved. Chemical analysis by energy dispersive X-ray spectrometer (EDX) shows the formation of (Co(Cr,Mo)) phase and the M23C6 precipitate on the CoCr surface; while quantitative analysis of the X-ray diffractometer (XRD) results demonstrates the oxidation of the Ti alloy with the formation of Ti2O and Ti6O from the reduction of the α-Ti phase. The behaviors were both related with an increase of the energy per unit length. Control of the final surface roughness was achieved by an electropolishing post-treatment, minimizing the as-treated values. After polishing, a reduction of surface roughness parameters was obtained in a range between 3% and 44%, while no changes in chemical composition or present phases were observed.

6.
Micromachines (Basel) ; 9(10)2018 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-30424418

RESUMO

Magnesium alloys are of increasing interest in the medical industry due to their biodegradability properties and better mechanical properties as compared to biodegradable polymers. Fiber laser cutting of AZ31 magnesium alloy tubes was carried out to study the effect of cutting conditions on wall surface roughness and back-wall dross. During the experiments, an argon gas chamber was adapted in order to avoid material reactivity with oxygen and thus better control the part quality. A surface response methodology was applied to identify the significance of pulse overlapping and pulse energy. Our results indicate minimum values of surface roughness (Ra < 0.7 µm) when the spot overlapping is higher than 50%. A back-wall dross range of 0.24% to 0.94% was established. In addition, a reduction in back-wall dross accumulations was obtained after blowing away the dross particles from inside the tube using an argon gas jet, reaching values of 0.21%. Laser cutting experimental models show a quadratic model for back-wall dross related with the interaction of the pulse energy, and a linear model dependent on pulse overlapping factor for surface roughness.

7.
Nanotechnology ; 28(42): 425302, 2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-28922139

RESUMO

We report the design, fabrication, and characterization of novel, low-cost, and modular miniaturized nanofiber electrospinning sources for the scalable production of non-woven aligned nanofiber mats with low diameter variation. The devices are monolithic arrays of electrospinning emitters made via stereolithography; the emitters are arranged so each element has an independent line of sight to a rotating collector surface. Linear and zigzag emitter packing were evaluated using a PEO solution with the aim of maximizing the throughput of nanofibers with the smallest diameter and narrowest distribution. Current versus flowrate characterization of the devices showed that for a given flowrate a zigzag array produces more current per emitter than a linear array of the same emitter pitch and array size. In addition, the data demonstrate that larger and denser arrays have a net gain in flow rate per unit of active length. Visual inspection of the devices suggests uniform operation in devices with as many as 17 emitters with 300 µm inner diameter and 1.5 mm emitter gap. Well-aligned nanofiber mats were collected on a rotating drum and characterized; the 17-emitter device produced the same narrow nanofiber distribution (∼81 nm average diameter, ∼17 nm standard deviation) for all tested flow rates, which is strikingly different to the performance shown by 1-emitter sources where the average fiber diameter significantly increased and the statistics notably widened when the flowrate increases. Therefore, the data demonstrate that massively multiplexing the emitters is a viable approach to greatly increase the throughput of non-woven aligned nanofiber mats without sacrificing the statistics of the nanofibers generated. The production of dry nanofibers by the 17-emitter array is estimated at 33.0 mg min-1 (1.38 mg min-1 per mm of active length), which compares favorably with the reported multiplexed electrospinning arrays with emitters distributed along a line.

8.
Micromachines (Basel) ; 9(1)2017 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-30393282

RESUMO

Laser cutting is a key technology for the medical devices industry, providing the flexibility, and precision for the processing of sheets, and tubes with high quality features. In this study, extensive experimentation was used to evaluate the effect of fiber laser micro-cutting parameters over average surface roughness ( R a ) and back wall dross ( D bw ) in AISI 316L stainless steel miniature tubes. A factorial design analysis was carried out to investigate the laser process parameters: pulse frequency, pulse width, peak power, cutting speed, and gas pressure. A real laser beam radius of 32.1 µm was fixed in all experiments. Through the appropriate combination of process parameters (i.e., high level of pulse overlapping factor, and pulse energy below 32 mJ) it was possible to achieve less than 1 µm in surface roughness at the edge of the laser-cut tube, and less than 3.5% dross deposits at the back wall of the miniature tube.

9.
PLoS One ; 10(4): e0122489, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25859853

RESUMO

BACKGROUND: Foams are high porosity and low density materials. In nature, they are a common architecture. Some of their relevant technological applications include heat and sound insulation, lightweight materials, and tissue engineering scaffolds. Foams derived from natural polymers are particularly attractive for tissue culture due to their biodegradability and bio-compatibility. Here, the foaming potential of an extensive list of materials was assayed, including slabs elaborated from whole flour, the starch component only, or the protein fraction only of maize seeds. METHODOLOGY/PRINCIPAL FINDINGS: We used supercritical CO2 to produce foams from thermoplasticized maize derived materials. Polyethylene-glycol, sorbitol/glycerol, or urea/formamide were used as plasticizers. We report expansion ratios, porosities, average pore sizes, pore morphologies, and pore size distributions for these materials. High porosity foams were obtained from zein thermoplasticized with polyethylene glycol, and from starch thermoplasticized with urea/formamide. Zein foams had a higher porosity than starch foams (88% and 85%, respectively) and a narrower and more evenly distributed pore size. Starch foams exhibited a wider span of pore sizes and a larger average pore size than zein (208.84 vs. 55.43 µm2, respectively). Proof-of-concept cell culture experiments confirmed that mouse fibroblasts (NIH 3T3) and two different prostate cancer cell lines (22RV1, DU145) attached to and proliferated on zein foams. CONCLUSIONS/SIGNIFICANCE: We conducted screening and proof-of-concept experiments on the fabrication of foams from cereal-based bioplastics. We propose that a key indicator of foamability is the strain at break of the materials to be foamed (as calculated from stress vs. strain rate curves). Zein foams exhibit attractive properties (average pore size, pore size distribution, and porosity) for cell culture applications; we were able to establish and sustain mammalian cell cultures on zein foams for extended time periods.


Assuntos
Materiais Biocompatíveis , Dióxido de Carbono , Zea mays , Animais , Técnicas de Cultura de Células , Linhagem Celular , Humanos , Teste de Materiais , Camundongos , Porosidade , Temperatura , Zeína
10.
Lab Chip ; 14(7): 1320-9, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24519447

RESUMO

We used continuous flow micro-devices as bioreactors for the production of a glycosylated pharmaceutical product (a monoclonal antibody). We cultured CHO cells on the surface of PMMA/PDMS micro-channels that had been textured by micromachining and coated with fibronectin. Three different micro-channel geometries (a wavy channel, a zigzag channel, and a series of donut-shape reservoirs) were tested in a continuous flow regime in the range of 3 to 6 µL min(-1). Both the geometry of the micro-device and the flow rate had a significant effect on cell adhesion, cell proliferation, and monoclonal antibody production. The most efficient configuration was a series of donut-shaped reservoirs, which yielded mAb concentrations of 7.2 mg L(-1) at residence times lower than one minute and steady-state productivities above 9 mg mL(-1) min(-1). These rates are at about 3 orders of magnitude higher than those observed in suspended-cell stirred tank fed-batch bioreactors.


Assuntos
Anticorpos Monoclonais/biossíntese , Reatores Biológicos , Proliferação de Células , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Proteínas Recombinantes/biossíntese , Animais , Células CHO , Adesão Celular , Cricetinae , Cricetulus
11.
Lab Chip ; 13(7): 1243-6, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23412111

RESUMO

We report a proof-of-principle for the use of micro-devices as continuous bioreactors for the production of monoclonal antibodies. We culture CHO cells on the surface of PMMA "zigzag" channels textured with semi-spherical cavities coated with fibronectin, observing steady-state productivities 100 times higher than those observed in full scale systems.


Assuntos
Anticorpos Monoclonais/biossíntese , Dispositivos Lab-On-A-Chip , Polimetil Metacrilato/química , Animais , Células CHO , Cricetinae , Cricetulus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...