2.
Emerg Radiol ; 28(3): 581-588, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33449260

RESUMO

PURPOSE: To evaluate the safety and image quality of extremity MR examinations performed with two MR conditional external fixators located in the MR bore. MATERIALS AND METHODS: Single-center retrospective study of a prospectively maintained imaging dataset that evaluated MR examinations of extremities in patients managed with external fixations instrumentation and imaged on a single 1.5T MR scanner. The fixation device was one of two MR-conditional instrumentation systems: DuPuy Synthes (aluminum, stainless steel, carbonium and Kevlar) or Dolphix temporary fixation system (PEEK-CA30). Safety events were recorded by the performing MR radiologic technologist. A study musculoskeletal radiologist assessed all sequences to evaluate for image quality, signal- and contrast-to-noise ratios (SNR/CNR), and injury patterns/findings. RESULTS: In the 13 men and 9 women with a mean age of 42 years (range 18 to 72 years), most patients (19/22 patients; 86%) were involved with trauma resulting in extremity injury requiring external fixation. MR examinations included 19 knee, 2 ankle, and 1 elbow examinations. There were no adverse safety events, heating that caused patient discomfort, fixation dislodgement/perturbment, or early termination of MR examinations. All examinations were of diagnostic quality. Fat-suppressed proton density sequences had significantly higher SNR and CNR compared to STIR (p = 0.01 to 0.04). The lower SNR of STIR and increased quality of fat-suppressed proton density during the study period led to the STIR sequence being dropped in standard MR protocol. CONCLUSION: MR of the extremity using the two study MR conditional external fixators within the MR bore is safe and feasible.


Assuntos
Fixadores Externos , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Extremidades , Feminino , Fixação de Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
3.
Sensors (Basel) ; 15(1): 1199-216, 2015 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-25585106

RESUMO

Prior information about the average dielectric properties of breast tissue can be implemented in microwave breast imaging techniques to improve the results. Rapidly providing this information relies on acquiring a limited number of measurements and processing these measurement with efficient algorithms. Previously, systems were developed to measure the transmission of microwave signals through breast tissue, and simplifications were applied to estimate the average properties. These methods provided reasonable estimates, but they were sensitive to multipath. In this paper, a new technique to analyze the average properties of breast tissues while addressing multipath is presented. Three steps are used to process transmission measurements. First, the effects of multipath were removed. In cases where multipath is present, multiple peaks were observed in the time domain. A Tukey window was used to time-gate a single peak and, therefore, select a single path through the breast. Second, the antenna response was deconvolved from the transmission coefficient to isolate the response from the tissue in the breast interior. The antenna response was determined through simulations. Finally, the complex permittivity was estimated using an iterative approach. This technique was validated using simulated and physical homogeneous breast models and tested with results taken from a recent patient study.


Assuntos
Mama/anatomia & histologia , Eletricidade , Micro-Ondas , Processamento de Sinais Assistido por Computador , Simulação por Computador , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Fatores de Tempo