Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagn Microbiol Infect Dis ; 107(2): 115959, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37536260

RESUMO

The BACT/ALERT® MP Reagent System is a broth culture medium for optimal detection and recovery of mycobacteria from clinical samples. The MP formulation was recently modified to improve detection and recovery times. A multicenter prospective matched pair study design was conducted to validate the performance of improved MP (MP-I) versus current MP (MP-C) bottles utilizing nonsterile and normally sterile samples, except blood, from patients suspected of having mycobacterial infections. A total of 1488 clinical samples were collected to obtain 212 mycobacteria samples by either or both MP culture bottles. MP-I and MP-C sensitivities were 86.6% and 81.4%, respectively, but the difference was not significant (P = 0.163) while specificities were 96.8% and 93.8%, respectively, and that difference was significant (P = 0.002). Overall recovery was 94.34% for MP-I and 88.68% for MP-C (recovery was 100% for both bottles with 52 seeded samples). Overall performance of MP-I was better than MP-C for sensitivity, specificity, and recovery.


Assuntos
Infecções por Mycobacterium , Mycobacterium , Humanos , Estudos Prospectivos , Meios de Cultura , Infecções por Mycobacterium/microbiologia , Kit de Reagentes para Diagnóstico
5.
Geriatr Nurs ; 42(1): 107-109, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33360318

RESUMO

A robust and comprehensive infection control plan in a senior living community is a must. Delirium manifestations of Covid-19 and or Urinary Tract Infections, may be confused or misdiagnosed with dementia symptoms in memory care residents. A robust incontinence care program is a key pillar of infection control to reduce symptoms causing hospitalization. Misdiagnosis, transfer infections, acute treatment dementia challenges, worsening incontinence are all risks of residents being hospitalized. A comprehensive incontinence assessment, plan, and education program are all paramount to seeing a reduction in hospitalizations and misdiagnosis of Covid-19 and other symptoms.


Assuntos
Moradias Assistidas/organização & administração , COVID-19/prevenção & controle , Controle de Infecções/organização & administração , Incontinência Urinária/terapia , Idoso , COVID-19/epidemiologia , COVID-19/transmissão , Humanos , Incontinência Urinária/diagnóstico , Incontinência Urinária/etiologia
8.
J Clin Microbiol ; 58(1)2019 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-31619532

RESUMO

Meropenem-vaborbactam (MEV) is a novel carbapenem-beta-lactamase inhibitor combination antibiotic approved by the U.S. Food and Drug Administration (FDA) for treatment of complicated urinary tract infections, including pyelonephritis, in adults. In this study, we evaluated the performance of Etest MEV (bioMérieux, Marcy l'Etoile, France) compared to that of broth microdilution for 629 Enterobacterales and 163 Pseudomonas aeruginosa isolates. According to CLSI/FDA breakpoints, 13 Enterobacterales isolates (12 clinical and 1 challenge) were resistant to MEV. Overall, Etest MEV demonstrated 92.4% essential agreement (EA), 99.2% category agreement (CA), 0% very major errors (VME), 0% major errors (ME), and 0.8% minor errors (mE) with clinical and challenge isolates of Enterobacterales Individual species demonstrated EA rates of ≥80%, with the exception of Proteus mirabilis, for which clinical and challenge isolates demonstrated 34.3% EA, 97.1% CA, 0% ME, and 2.9% mE, precluding the use of Etest MEV with this species. Excluding P. mirabilis, MEV Etest MEV demonstrated 95.8% EA, 99.3% CA, 0% VME, 0% ME, and 0.7% mE with Enterobacterales isolates. When evaluated using European Committee on Antimicrobial Susceptibility Testing (EUCAST) breakpoints, Etest MEV performance with clinical (16 MEV resistant) and challenge (12 MEV resistant) isolates of Enterobacterales (excluding P. mirabilis) and P. aeruginosa demonstrated an unacceptably high VME rate of 7.1% despite 95.2% EA, 99.2% CA, and 0.5% ME compared to the reference method. In conclusion, we report that Etest MEV is accurate and reproducible for MEV susceptibility testing for P. aeruginosa and Enterobacterales, with the exception of P. mirabilis, using CLSI/FDA breakpoints. Etest MEV should not be used with P. mirabilis due to unacceptable analytical performance.


Assuntos
Antibacterianos/farmacologia , Ácidos Borônicos/farmacologia , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão , Enterobacteriaceae/efeitos dos fármacos , Meropeném/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Combinação de Medicamentos , Humanos , Reprodutibilidade dos Testes
9.
Geriatr Nurs ; 40(3): 338-341, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31202425

RESUMO

A total incontinence management program will benefit a community's administration, nurses, caregivers, families and most importantly, residents. An incontinence program helps reduce the risk of incidences such as agitation, urinary tract infection, falls and skin complications which assisted living and memory care communities are trying to prevent. The correct evaluation tools increase the likelihood of successful outcomes because the program has to be the right program for the resident. After evaluation of the level of incontinence, the resident can then be enrolled. This article provides a practical toolkit for assessment of a resident in assisted living general or memory care populations in addition to the different types of programs a resident can enroll into after evaluation completed.


Assuntos
Moradias Assistidas , Enfermagem Geriátrica , Inquéritos e Questionários , Incontinência Urinária/enfermagem , Idoso , Cuidadores , Feminino , Humanos , Infecções Urinárias/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...