Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Sports Physiol Perform ; 14(10): 1442-1446, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30958044

RESUMO

OBJECTIVE: To compare the accuracy of different devices to predict the bench-press 1-repetition maximum (1RM) from the individual load-velocity relationship modeled through the multiple- and 2-point methods. METHODS: Eleven men performed an incremental test on a Smith machine against 5 loads (45-55-65-75-85%1RM), followed by 1RM attempts. The mean velocity was simultaneously measured by 1 linear velocity transducer (T-Force), 2 linear position transducers (Chronojump and Speed4Lift), 1 camera-based optoelectronic system (Velowin), 2 inertial measurement units (PUSH Band and Beast Sensor), and 1 smartphone application (My Lift). The velocity recorded at the 5 loads (45-55-65-75-85%1RM), or only at the 2 most distant loads (45-85%1RM), was considered for the multiple- and 2-point methods, respectively. RESULTS: An acceptable and comparable accuracy in the estimation of the 1RM was observed for the T-Force, Chronojump, Speed4Lift, Velowin, and My Lift when using both the multiple- and 2-point methods (effect size ≤ 0.40; Pearson correlation coefficient [r] ≥ .94; standard error of the estimate [SEE] ≤ 4.46 kg), whereas the accuracy of the PUSH (effect size = 0.70-0.83; r = .93-.94; SEE = 4.45-4.80 kg), and especially the Beast Sensor (effect size = 0.36-0.84; r = .50-.68; SEE = 9.44-11.2 kg), was lower. CONCLUSIONS: These results highlight that the accuracy of 1RM prediction methods based on movement velocity is device dependent, with the inertial measurement units providing the least accurate estimate of the 1RM.

2.
J Strength Cond Res ; 33(5): 1258-1265, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31034462

RESUMO

Pérez-Castilla, A, Piepoli, A, Delgado-García, G, Garrido-Blanca, G, and García-Ramos, A. Reliability and concurrent validity of seven commercially available devices for the assessment of movement velocity at different intensities during the bench press. J Strength Cond Res 33(5): 1258-1265, 2019-The aim of this study was to compare the reliability and validity of 7 commercially available devices to measure movement velocity during the bench press exercise. Fourteen men completed 2 testing sessions. One-repetition maximum (1RM) in the bench press exercise was determined in the first session. The second testing session consisted of performing 3 repetitions against 5 loads (45, 55, 65, 75, and 85% of 1RM). The mean velocity was simultaneously measured using an optical motion sensing system (Trio-OptiTrack; "gold-standard") and 7 commercially available devices: 1 linear velocity transducer (T-Force), 2 linear position transducers (Chronojump and Speed4Lift), 1 camera-based optoelectronic system (Velowin), 1 smartphone application (PowerLift), and 2 inertial measurement units (IMUs) (PUSH band and Beast sensor). The devices were ranked from the most to the least reliable as follows: (a) Speed4Lift (coefficient of variation [CV] = 2.61%); (b) Velowin (CV = 3.99%), PowerLift (3.97%), Trio-OptiTrack (CV = 4.04%), T-Force (CV = 4.35%), and Chronojump (CV = 4.53%); (c) PUSH band (CV = 9.34%); and (d) Beast sensor (CV = 35.0%). A practically perfect association between the Trio-OptiTrack system and the different devices was observed (Pearson's product-moment correlation coefficient (r) range = 0.947-0.995; p < 0.001) with the only exception of the Beast sensor (r = 0.765; p < 0.001). These results suggest that linear velocity/position transducers, camera-based optoelectronic systems, and the smartphone application could be used to obtain accurate velocity measurements for restricted linear movements, whereas the IMUs used in this study were less reliable and valid.


Assuntos
Teste de Esforço/instrumentação , Teste de Esforço/normas , Força Muscular/fisiologia , Treinamento Resistido/instrumentação , Adulto , Coleta de Dados , Teste de Esforço/métodos , Humanos , Masculino , Aplicativos Móveis , Movimento (Física) , Reprodutibilidade dos Testes , Treinamento Resistido/métodos , Transdutores , Adulto Jovem