Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Echocardiography ; 36(8): 1475-1481, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31260156

RESUMO

PURPOSE: To describe clinical and echocardiographic characteristics associated with reverse left ventricular (LV) remodeling after 6 months of cardiac resynchronization therapy (CRT) in patients with nonischemic dilated cardiomyopathy. METHODS: Twenty-four consecutive patients underwent 2D and 3D echocardiography before and after 6 months of CRT implant. Several echocardiographic parameters including global longitudinal strain (GLS) and 3D mechanical dyssynchrony (MD) index were calculated. CRT response was defined as a decrease in LV end-systolic volume (LVESV) of at least 10% at follow-up. Patients were divided in two groups according to CRT response. RESULTS: Cardiac resynchronization therapy responder (CRTR+) rate was 50%. Nonresponder (CRTR-) patients showed a less significant improvement in NYHA class at follow-up. At baseline, CRTR- presented with higher LV end-diastolic volume (LVEDV) (P = 0.031), LVESV (P = 0.024), lower left ventricular ejection fraction (LVEF) (P = 0.002) and less negative GLS (P = 0.03), and with higher diastolic dysfunction, more impaired right ventricle (RV), and higher pulmonary artery systolic pressure (PASP) (P = 0.002). No significant differences in echocardiographic parameters of MD were found. Univariate determinants of CRTR+ were LVEF (OR = 1.59, CI 95% = 1.13-2.22, P = 0.007) and TAPSE (OR 1.21, CI 95% = 1.024-1.429, P = 0.025). A ROC curve analysis showed a cutoff value of LVEF of 22.15% significantly related to CRTR+ (SE 80%, SP 50%). CONCLUSIONS: Our findings suggest that end-stage HF patients, presenting before CRT with LVEF <22.15%, may not benefit from the procedure after 6 months. Mechanical dyssyncronicity did not provide additional information to improve candidate selection.


Assuntos
Cardiomiopatia Dilatada/terapia , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Clin Case Rep ; 7(2): 322-327, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30847198

RESUMO

Delayed efficacy of radiofrequency energy can suppress ventricular arrhythmias after a failed ablation procedure. The implant of cardiac defibrillator for arrhythmia-induced cardiomyopathy should be procrastinated after a period of follow-up. Waiting for delayed efficacy is a reasonable choice to reduce the risk of complications associated with aggressive ablative approaches.

3.
Cardiol Young ; 27(1): 74-81, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26940122

RESUMO

BACKGROUND: In 2010, an Italian project was launched aimed at using a telecardiology device in order to perform early diagnosis of young students at risk of sudden cardiac death. METHODS: Our retrospective observational study was conducted on a population of 13,016 students, aged between 16 and 19 years, in different Italian regions. It consisted of analysis of data recorded during a telecardiology pilot study. The recorded data were electrocardiograms and data concerning lifestyle habits and family history of cardiovascular diseases. In total, 14 alterations in the electrocardiogram signal have been considered in this study. Some of these alterations are as follows: ventricular ectopic beats, atrioventricular block, Brugada-like electrocardiogram pattern, left anterior/posterior fascicular block, left/right ventricular hypertrophy, long/short QT interval, left atrial enlargement, right atrial enlargement, short PQ interval, and ventricular pre-excitation Wolff-Parkinson-White syndrome. On the basis of the collected data, we implemented this retrospective observational study. RESULTS: The analysed data showed that 13.60% of students had a family history for cardiovascular diseases, 22.43% reported smoking habits, 26.23% reported alcohol consumption, and 7.24% reported abuse of drugs. A total of 24% of students had at least one of the 14 electrocardiogram pathological alterations considered in our study and 32% had electrocardiogram values within the normal range. CONCLUSIONS: This retrospective observational study analysed data registered during our telecardiology activity. This activity permitted to maximise data collection and minimise the costs for collecting such data. This activity of screening is being continued and in the next few years it will allow us to have a greater mass of data.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Programas de Rastreamento/métodos , Estudantes/estatística & dados numéricos , Telemedicina/métodos , Adolescente , Morte Súbita Cardíaca/epidemiologia , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Projetos Piloto , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...