RESUMO

BACKGROUND: Little is known about the effect of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement. We reported previously an increased risk of PPM with the SAPIEN 3 transcatheter heart valve (S3-THV). AIMS: To investigate the association of PPM with 1-year outcomes in patients with severe aortic stenosis (AS) implanted with S3-THV. METHODS: Moderate PPM was defined by an indexed effective orifice area (iEOA)≤0.85cm2/m2, and severe PPM by an iEOA<0.65cm2/m2. Inclusion criteria were severe symptomatic AS and implantation with S3-THV. The primary endpoint was hospitalization for congestive heart failure (CHF) at 1 year; the secondary endpoint was all-cause mortality. RESULTS: A total of 208 consecutive patients were included between 2016 and 2018. Male sex was prevalent (53.8%), mean age was 81.9±6.2 years, mean EuroSCORE II was 4.35±3.37, mean LVEF was 57.9±13%. Moderate and severe PPM were observed in 69 (33.2%) and 10 (4.8%) patients. Patients with PPM were younger (80.4±7 vs 82.8±5.41 years; P=0.006), had a larger BSA (1.84±0.19 vs 1.77±0.19 m2; P=0.01), a lower iEOA (0.73±0.08 vs 1.11±0.22 cm2/m2; P<0.001) and a higher mean gradient (14±4.6 vs 11.9±3.9mmHg; P<0.001). CHF occurred in 16.5% vs 7% (P=0.03). By multivariable analysis, PPM was independently associated with CHF (hazard ratio [HR] 3.17, 95% confidence interval [CI] 1.17 to 8.55; P=0.032), especially in patients with mitral regurgitation≥2/4 (HR>100, 95%CI>100 to>1000; P<0.01). PPM did not correlate with all-cause mortality (HR 0.90, 95%CI 0.22 to 3.03; P=0.86). CONCLUSIONS: PPM after S3-THV implantation is strongly associated with CHF at 1 year, but is not correlated with overall mortality.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/etiologia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Arch Cardiovasc Dis ; 113(5): 321-331, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32249166

RESUMO

BACKGROUND: Diagnosis of left ventricular non-compaction (LVNC) is challenging, and different imaging techniques propose different criteria. AIM: To compare the value of two-dimensional transthoracic echocardiography (2D-TTE) and cardiac magnetic resonance (CMR) criteria in diagnosing LVNC, and to test a new trabecular quantification method obtained by 2D-TTE, exploring its relationship with CMR non-compacted mass quantification. METHODS: From a multicentre French study, we selected 48 patients with LVNC and 20 with dilated cardiomyopathy (DCM) who underwent 2D-TTE and CMR. Current 2D-TTE (Jenni et al.) and CMR criteria (Petersen et al., Jacquier et al.), were tested. A new 2D-TTE method of trabecular quantification (percentage of trabecular area) was also proposed, and compared with current criteria. RESULTS: The best cut-off values for the diagnosis of LVNC were a non-compacted/compacted ratio≥2.3 (Petersen et al.), a trabeculated left ventricular mass≥20% (Jacquier et al.) and a non-compacted/compacted ratio≥1.8 (Jenni et al.). Lowering the threshold for the criterion of Jenni et al. from>2 to ≥1.8 improved its sensitivity from 69% to 98%. The 2D-TTE percentage of trabecular area was 25.9±8% in the LVNC group vs. 9.9±4.4% in the DCM group (P<0.05), and was well correlated with CMR non-compacted mass (r=0.65; P<0.05). A 15.8% threshold value for 2D-TTE percentage of trabecular area predicted LVNC diagnosis with a specificity of 95% and a sensitivity of 92%; its sensitivity was better than that for the criteria of Jenni et al. (P<0.01) and Petersen et al. (P=0.03). CONCLUSIONS: Revision of the current threshold for the criterion of Jenni et al. from>2 to ≥1.8 is necessary to improve LVNC diagnosis in patients with left ventricular dysfunction. A new 2D-TTE trabecular quantification method improves TTE diagnosis of LVNC.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Miocárdio Ventricular não Compactado Isolado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Adulto , Diagnóstico Diferencial , Feminino , França , Ventrículos do Coração/anormalidades , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes