Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(6): 066101, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611055

RESUMO

A creative low-cost and compact mechanical device that mimics the rapid closure of the pistol shrimp claw was used to conduct electrochemical experiments, in order to study the effects of hydrodynamic cavitation on the corrosion of aluminum and steel samples. Current-time curves show significant changes associated with local variations in dissolved O2 concentration, cavitation-induced erosion, and changes in the nature of the surface corrosion products.

2.
Sci Rep ; 8(1): 14968, 2018 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-30297857

RESUMO

The effect of viscoelastic additives on the topology and dynamics of the two-phase flow arising within an axisymmetric orifice with a flow path constriction along its main axis has been investigated employing high-flux synchrotron radiation. X-ray Phase Contrast Imaging (XPCI) has been conducted to visualise the cavitating flow of different types of diesel fuel within the orifice. An additised blend containing Quaternary Ammonium Salt (QAS) additives with a concentration of 500 ppm has been comparatively examined against a pure (base) diesel compound. A high-flux, 12 keV X-ray beam has been utilised to obtain time resolved radiographs depicting the vapour extent within the orifice from two views (side and top) with reference to its main axis. Different test cases have been examined for both fuel types and for a range of flow conditions characterised by Reynolds number of 35500 and cavitation numbers (CN) lying in the range 3.0-7.7. It has been established that the behaviour of viscoelastic micelles in the regions of shear flow is not consistent depending on the cavitation regimes encountered. Namely, viscoelastic effects enhance vortical (string) cavitation, whereas hinder cloud cavitation. Furthermore, the use of additised fuel has been demonstrated to suppress the level of turbulence within the orifice.

3.
Rev Sci Instrum ; 88(3): 033706, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372445

RESUMO

An experimental technique for the estimation of the temporal-averaged vapour volume fraction within high-speed cavitating flow orifices is presented. The scientific instrument is designed to employ X-ray micro computed tomography (microCT) as a quantitative 3D measuring technique applied to custom designed, large-scale, orifice-type flow channels made from Polyether-ether-ketone (PEEK). The attenuation of the ionising electromagnetic radiation by the fluid under examination depends on its local density; the transmitted radiation through the cavitation volume is compared to the incident radiation, and combination of radiographies from sufficient number of angles leads to the reconstruction of attenuation coefficients versus the spatial position. This results to a 3D volume fraction distribution measurement of the developing multiphase flow. The experimental results obtained are compared against the high speed shadowgraph visualisation images obtained in an optically transparent nozzle with identical injection geometry; comparison between the temporal mean image and the microCT reconstruction shows excellent agreement. At the same time, the real 3D internal channel geometry (possibly eroded) has been measured and compared to the nominal manufacturing CAD drawing of the test nozzle.

4.
Phys Med Biol ; 55(5): 1395-411, 2010 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-20150685

RESUMO

Flow patterns may affect the potential of thrombus formation following plaque rupture. Computational fluid dynamics (CFD) were employed to assess hemodynamic conditions, and particularly flow recirculation and vortex formation in reconstructed arterial models associated with ST-elevation myocardial infraction (STEMI) or stable coronary stenosis (SCS) in the left anterior descending coronary artery (LAD). Results indicate that in the arterial models associated with STEMI, a 50% diameter stenosis immediately before or after a bifurcation creates a recirculation zone and vortex formation at the orifice of the bifurcation branch, for most of the cardiac cycle, thus allowing the creation of stagnating flow. These flow patterns are not seen in the SCS model with an identical stenosis. Post-stenotic recirculation in the presence of a 90% stenosis was evident at both the STEMI and SCS models. The presence of 90% diameter stenosis resulted in flow reduction in the LAD of 51.5% and 35.9% in the STEMI models and 37.6% in the SCS model, for a 10 mmHg pressure drop. CFD simulations in a reconstructed model of stenotic LAD segments indicate that specific anatomic characteristics create zones of vortices and flow recirculation that promote thrombus formation and potentially myocardial infarction.


Assuntos
Circulação Coronária , Estenose Coronária/fisiopatologia , Hemodinâmica , Modelos Biológicos , Simulação por Computador , Oclusão Coronária/etiologia , Estenose Coronária/complicações , Estenose Coronária/patologia , Humanos , Modelos Anatômicos , Infarto do Miocárdio/etiologia
5.
Phys Med Biol ; 53(18): 4875-92, 2008 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-18711245

RESUMO

This study aimed at investigating the effect of myocardial motion on pulsating blood flow distribution of the left anterior descending coronary artery in the presence of atheromatous stenosis. The moving 3D arterial tree geometry has been obtained from conventional x-ray angiograms obtained during the heart cycle and includes a number of major branches. The geometry reconstruction model has been validated against projection data from a virtual phantom arterial tree as well as with CT-based reconstruction data for the same patient investigated. Reconstructions have been obtained for a number of temporal points while linear interpolation has been used for all intermediate instances. Blood has been considered as a non-Newtonian fluid. Results have been obtained using the same pulse for the inlet blood flow rate but with fixed arterial tree geometry as well as under steady-state conditions corresponding to the mean flow rate. Predictions indicate that myocardial motion has only a minor effect on flow distribution within the arterial tree relative to the effect of the blood pressure pulse.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiologia , Coração/fisiologia , Modelos Cardiovasculares , Movimento/fisiologia , Fluxo Pulsátil/fisiologia , Animais , Simulação por Computador , Humanos , Dinâmica não Linear
6.
J Colloid Interface Sci ; 300(2): 673-87, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16774763

RESUMO

The detachment of liquid droplets from porous material surfaces used with proton exchange membrane (PEM) fuel cells under the influence of a cross-flowing air is investigated computationally and experimentally. CCD images taken on a purpose-built transparent fuel cell have revealed that the water produced within the PEM is forming droplets on the surface of the gas-diffusion layer. These droplets are swept away if the velocity of the flowing air is above a critical value for a given droplet size. Static and dynamic contact angle measurements for three different carbon gas-diffusion layer materials obtained inside a transparent air-channel test model have been used as input to the numerical model; the latter is based on a Navier-Stokes equations flow solver incorporating the volume of fluid (VOF) two-phase flow methodology. Variable contact angle values around the gas-liquid-solid contact-line as well as their dynamic change during the droplet shape deformation process, have allowed estimation of the adhesion force between the liquid droplet and the solid surface and successful prediction of the separation line at which droplets loose their contact from the solid surface under the influence of the air stream flowing around them. Parametric studies highlight the relevant importance of various factors affecting the detachment of the liquid droplets from the solid surface.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA