Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 30(1): 12-7, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11948261

RESUMO

OBJECTIVE: Our objective was to show the advantages of performing whole-body lymphoscintigraphy using transmission sources. This technique should decrease scanning time, help locate the sentinel lymph node, and decrease radiation exposure to the technologist. METHODS: Twenty patients with proven melanoma received 18.5 MBq (0.5 mCi) filtered (0.22 microm) (99m)Tc-sulfur colloid in a 0.2-mL volume, administered as multiple intradermal or subcutaneous injections around the known melanoma lesion or scar. All 20 patients underwent serial static imaging immediately after the injection, along with whole-body scanning after the static imaging. The static emission images were acquired for 5 min and the transmission images for 1 min using a 256 x 256 matrix. The whole-body transmission scans were acquired after the whole-body emission scans. The transmission scans were obtained with the same parameters as the emission scans, with the addition of placement of a (57)Co sheet source on one of the detectors of the large-field-of-view dual-head camera. The planar static axial images (transmission, emission) were compared with the whole-body images (transmission, emission) to determine whether the same number of lymph nodes was visualized with each technique. Posterior outlines were obtained through computer manipulation of anterior transmission images. RESULTS: In all 20 patients, the number of lymph nodes seen on the static images was the same as that seen on the whole-body emission and transmission images. The whole-body emission and transmission scanning time was an average of 30 min less than the time required to acquire the serial static images. CONCLUSION: The anatomic location of the sentinel lymph node is seen more easily on whole-body images, both anterior transmission and posterior transmission, than on planar static images. Whole-body emission and transmission imaging decreased scanning time and thus improved patient comfort and throughput. Technologists received less radiation exposure when handling the (57)Co source only twice during whole-body imaging, as opposed to several times during static imaging.


Assuntos
Linfocintigrafia , Melanoma/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Humanos , Metástase Linfática , Melanoma/secundário , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela , Coloide de Enxofre Marcado com Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA