Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 120(13): 132502, 2018 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-29694188

RESUMO

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-ß decay in ^{76}Ge. The Majorana Demonstrator comprises 44.1 kg of Ge detectors (29.7 kg enriched in ^{76}Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at Q_{ßß} and a very low background with no observed candidate events in 9.95 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of 1.9×10^{25} yr (90% C.L.). This result constrains the effective Majorana neutrino mass to below 240-520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4.0_{-2.5}^{+3.1} counts/(FWHM t yr).

2.
Phys Rev Lett ; 118(26): 261301, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28707937

RESUMO

The first searches for axions and axionlike particles with the Large Underground Xenon experiment are presented. Under the assumption of an axioelectric interaction in xenon, the coupling constant between axions and electrons g_{Ae} is tested using data collected in 2013 with an exposure totaling 95 live days ×118 kg. A double-sided, profile likelihood ratio statistic test excludes g_{Ae} larger than 3.5×10^{-12} (90% C.L.) for solar axions. Assuming the Dine-Fischler-Srednicki-Zhitnitsky theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c^{2}, while for the Kim-Shifman-Vainshtein-Zhakharov description masses above 36.6 eV/c^{2} are excluded. For galactic axionlike particles, values of g_{Ae} larger than 4.2×10^{-13} are excluded for particle masses in the range 1-16 keV/c^{2}. These are the most stringent constraints to date for these interactions.

3.
Phys Rev Lett ; 118(25): 251302, 2017 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-28696768

RESUMO

We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg yr exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% C.L. upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of σ_{n}=1.6×10^{-41} cm^{2} (σ_{p}=5×10^{-40} cm^{2}) at 35 GeV c^{-2}, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.

4.
Phys Rev Lett ; 118(2): 021303, 2017 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-28128598

RESUMO

We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×10^{4} kg day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV c^{-2}, WIMP-nucleon spin-independent cross sections above 2.2×10^{-46} cm^{2} are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1×10^{-46} cm^{2} at 50 GeV c^{-2}.

5.
Phys Rev Lett ; 116(16): 161301, 2016 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-27152785

RESUMO

We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including 1.4×10^{4} kg day of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium ß source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 GeV c^{-2}, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 GeV c^{-2} WIMP mass.

6.
Phys Rev Lett ; 116(16): 161302, 2016 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-27152786

RESUMO

We present experimental constraints on the spin-dependent WIMP (weakly interacting massive particle)-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of 1.4×10^{4} kg day of fiducial exposure allows 90% C.L. upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of σ_{n}=9.4×10^{-41} cm^{2} (σ_{p}=2.9×10^{-39} cm^{2}) at 33 GeV/c^{2}. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.

7.
Phys Rev Lett ; 112(9): 091303, 2014 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-24655239

RESUMO

The Large Underground Xenon (LUX) experiment is a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota). The LUX cryostat was filled for the first time in the underground laboratory in February 2013. We report results of the first WIMP search data set, taken during the period from April to August 2013, presenting the analysis of 85.3 live days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of 7.6 × 10(-46) cm(2) at a WIMP mass of 33 GeV/c(2). We find that the LUX data are in disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.

8.
J Opt Soc Am A Opt Image Sci Vis ; 18(2): 385-91, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11205985

RESUMO

The small-angle approximation to the radiative transport equation is used extensively in imaging models in which the transport medium is optically thick. The small-angle approximation is generally considered valid when the particles are very large compared with the wavelength, when the refractive-index ratio of the particle to the medium is close to 1, and when the optical thickness is not too large. We report results showing the limits of the validity of the small-angle approximation as a function of particle size and concentration for a particle-to-medium fixed refractive-index ratio of 1.196. This refractive-index ratio is comparable with that of minerals or diatoms suspended in water.

9.
Appl Opt ; 40(21): 3608-13, 2001 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-18360390

RESUMO

The small-angle approximation to the radiative transport equation is applied to particle suspensions that emulate ocean water. A particle size distribution is constructed from polystyrene and glass spheres with the best available data for particle size distributions in the ocean. A volume scattering function is calculated from the Mie theory for the particles in water and in oil. The refractive-index ratios of particles in water and particles in oil are 1.19 and 1.01, respectively. The ratio 1.19 is comparable to minerals and nonliving diatoms in ocean water, and the ratio 1.01 is comparable to the lower limit for microbes in water. The point-spread functions are measured as a function of optical thickness for both water and oil mixtures and compared with the point-spread functions generated from the small-angle approximation. Our results show that, under conditions that emulate ocean water, the small-angle approximation is valid only for small optical thicknesses. Specifically, the approximation is valid only for optical thicknesses less than 3.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...