Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Membranes (Basel) ; 13(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38132897

RESUMO

The low-fouling propensity of commercially available polyethersulfone (PES) membranes was studied after modification of the membrane surface via coating with polymerizable bicontinuous microemulsion (PBM) materials. The PBM coating was polymerized within 1 min using ultraviolet (UV) light exposure. It was detected on the PES membrane surface via attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy. The PBM coating led to an average 10% increase in the hydrophilicity of the PES membrane surface and an increase in total organic content (TOC) removal by more than 15%. Flux-step tests were conducted with model foulant comprising 100 mg L-1 humic acid (HA) solution to detect the onset of critical fouling, characterized by a rapid and substantial increase in TMP, and to compare the fouling propensity of commercially available PES membranes with PBM-coated membranes. The critical flux was found to be about 40% higher for PBM spray-coated membrane and 20% lower for PBM casting-coated membrane than the commercial PES membrane. This demonstrates the performance advantages of the thin PBM layer spray-coated on PES membrane compared to the thick casting-coated PBM layer. The study showcases the potential of PBM spray-coated membranes over commercial PES membranes for use in membrane bioreactors (MBR) for wastewater treatment systems with reduced maintenance over longer operation periods.

2.
MethodsX ; 3: 320-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27158597

RESUMO

This paper describes a device that allows for simultaneous tomographic imaging of samples on three independent rotational axes. This rotation axis demultiplexer (POLYTOM) is equipped with anti-backlash gears and placed on a standard sample rotation stage thus allowing for the transformation of the input rotation axis onto two additional parallel vertical axes. Consequently, three times the number of samples can be investigated within a given time period, thereby reducing the acquisition time of multiple sample tomographic investigations by a factor of three. The results of our pilot experiments using neutron tomographic imaging are presented. We foresee that the device will be of particular use for tomographic imaging of elongated samples at low-flux (e.g. neutron) sources; however, its use for the more widespread types of imaging techniques (e.g. X-rays) is not ruled out. The highlights of this new device for the purpose of the (neutron) computed tomography are: •Anti-backlash transformation of the input rotation onto two additional rotational axes.•Reduction of the acquisition time of the multiple sample tomographic investigations by a factor of three.•Low-cost.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...