1.
J Nucl Cardiol ; 30(2): 516-527, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35760983

RESUMO

BACKGROUND: As myocardial blood flow measurement (MBF) in SPECT systems became recently available, significant effort has been devoted to its validation. For that purpose, we have developed a cardiac phantom that is able to mimic physiological radiotracer variation in the left ventricle cavity and in the myocardium, while performing beating-like motion. The new phantom is integrated inside a standard anthropomorphic torso allowing a realistic tissue attenuation and gamma-ray scattering METHODS AND RESULTS: A mechanical cardiac phantom was integrated in a commercially available anthropomorphic torso. Using a GE Discovery 530c SPECT, measurements were performed. It was found that gamma-ray attenuation effects are significant and limit the MBF measurements to global/three-vessel resolution. Dynamic SPECT experiments were performed to validate MBF accuracy and showed mean relative error of 14%. Finally, the effect of varying radiotracer dose on the accuracy of dynamic SPECT was studied CONCLUSIONS: A dynamic cardiac phantom has been developed and successfully integrated in a standard SPECT torso. A good agreement was found between SPECT-reported MBF values and the expected results. Despite increased noise-to-signal ratio when radiotracer doses were reduced, MBF uncertainty did not increase significantly down to very low doses, thanks to the temporal integration of the activity during the measurement.


Assuntos
Coração , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Miocárdio , Imagens de Fantasmas , Movimento (Física)
2.
J Nucl Cardiol ; 30(4): 1341-1351, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36477896

RESUMO

BACKGROUND: Coronary flow reserve (CFR) values measured by dynamic SPECT systems are typically consistent with other modalities (e.g., PET). However, large discrepancies are often observed for individual patients. Positioning of the region-of-interest (ROI), representing the arterial input function (AIF) could explain some of these discrepancies. We explored the possibility of positioning the ROI in a manner that evaluates its consistency with patient-based injected radiotracer doses. METHODS: Dose-consistent dynamic SPECT methodology was introduced, and its application was demonstrated in a twenty-patient clinical study. The effect of various ROI positions was investigated and comparison to myocardial perfusion imaging was performed. RESULTS: Mean AIF ratios were consistent with the injected dose ratios for all examined ROI positions. Good agreement (> 80%) between total perfusion deficit and CFR was found in the detection of obstructive CAD patients for all ROIs considered. However, for individual patients, significant dependence on ROI position was observed (altering CFR by typically 30%). The proposed methodology's uncertainty was evaluated (~ 7%) and found to be smaller than the variability due to choice of ROI position. CONCLUSION: Dose-consistent dynamic SPECT may contribute to evaluating uncertainty of CFR measurements and may potentially decrease uncertainty by allowing improved ROI positioning for individual patients.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem de Perfusão do Miocárdio/métodos