Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Adv ; 10(3): eadk7957, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38232164

RESUMO

Four-dimensional ultrasound imaging of complex biological systems such as the brain is technically challenging because of the spatiotemporal sampling requirements. We present computational ultrasound imaging (cUSi), an imaging method that uses complex ultrasound fields that can be generated with simple hardware and a physical wave prediction model to alleviate the sampling constraints. cUSi allows for high-resolution four-dimensional imaging of brain hemodynamics in awake and anesthetized mice.


Assuntos
Encéfalo , Hemodinâmica , Camundongos , Animais , Encéfalo/diagnóstico por imagem , Ultrassonografia , Vigília
2.
IEEE Trans Ultrason Ferroelectr Freq Control ; 70(12): 1726-1738, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37938952

RESUMO

Functional ultrasound (fUS) using a 1-D-array transducer normally is insufficient to capture volumetric functional activity due to being restricted to imaging a single brain slice at a time. Typically, for volumetric fUS, functional recordings are repeated many times as the transducer is moved to a new location after each recording, resulting in a nonunique average mapping of the brain response and long scan times. Our objective was to perform volumetric 3-D fUS in an efficient and cost-effective manner. This was achieved by mounting a 1-D-array transducer to a high-precision motorized linear stage and continuously translating over the mouse brain in a sweeping manner. We show how the speed at which the 1-D-array is translated over the brain affects the sampling of the hemodynamic response (HR) during visual stimulation as well as the quality of the resulting power Doppler image (PDI). Functional activation maps were compared between stationary recordings, where only one functional slice is obtained for every recording, and our swept-3-D method, where volumetric fUS was achieved in a single functional recording. The results show that the activation maps obtained with our method closely resemble those obtained during a stationary recording for that same location, while our method is not restricted to functional imaging of a single slice. Lastly, a mouse brain subvolume of ~6 mm is scanned at a volume rate of 1.5 s per volume, with a functional PDI reconstructed every [Formula: see text], highlighting swept-3-D's potential for volumetric fUS. Our method provides an affordable alternative to volumetric fUS using 2-D-matrix transducers, with a high SNR due to using a fully sampled 1-D-array transducer, and without the need to repeat functional measurements for every 2-D slice, as is most often the case when using a 1-D-array. This places our swept-3-D method as a potentially valuable addition to conventional 2-D fUS, especially when investigating whole-brain functional connectivity, or when shorter recording durations are desired.


Assuntos
Encéfalo , Ultrassonografia Doppler , Camundongos , Animais , Ultrassonografia , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
3.
IEEE Trans Ultrason Ferroelectr Freq Control ; 70(12): 1714-1725, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37788196

RESUMO

Volumetric 3-D Doppler ultrasound imaging can be used to investigate large scale blood dynamics outside of the limited view that conventional 2-D power Doppler images (PDIs) provide. To create 3-D PDIs, 2-D-matrix array transducers can be used to insonify a large volume for every transmission; however, these matrices suffer from low sensitivity, high complexity, and high cost. More typically, a 1-D-array transducer is used to scan a series of stationary 2-D PDIs, after which a 3-D volume is created by concatenating the 2-D PDIs in postprocessing, which results in long scan times due to repeated measurements. Our objective was to achieve volumetric 3-D Doppler ultrasound imaging with a high Doppler sensitivity, similar to that of a typical stationary recording using a 1-D-array transducer, while being more affordable than using 2-D-matrix arrays. We achieved this by mounting a 1-D-array transducer to a high-precision motorized linear stage and continuously translating over the mouse brain in a sweeping manner. For Part I of this article, we focused on creating the best vascular images by investigating how to best combine filtered beamformed ultrasound frames, which were not acquired at the same spatial locations, into PDIs. Part II focuses on the implications of sampling transient brain hemodynamics through functional ultrasound (fUS) while continuously translating over the mouse brain. In Part I, we show how the speed at which we sweep our 1-D-array transducer affects the Doppler spectrum in a flow phantom. In vivo recordings were performed on the mouse brain while varying the sweeping speed, showing how higher sweeping speeds negatively affect the PDI quality. A weighting vector is found to combine frames while continuously moving over the mouse brain, allowing us to create swept PDIs of similar sensitivity when compared with those obtained using a stationary 1-D-array while allowing a significantly higher 3-D Doppler volume rate and maintaining the benefits of having a low computational and monetary cost. We show that a vascular subvolume of 6 mm can be scanned in 2.5 s, with a PDI reconstructed every [Formula: see text], outperforming classical staged recording methods.


Assuntos
Imageamento Tridimensional , Ultrassonografia Doppler , Animais , Camundongos , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Imagens de Fantasmas , Imageamento Tridimensional/métodos , Transdutores
4.
Front Surg ; 10: 1153605, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37342792

RESUMO

Surgical resection of spinal cord hemangioblastomas remains a challenging endeavor: the neurosurgeon's aim to reach total tumor resections directly endangers their aim to minimize post-operative neurological deficits. The currently available tools to guide the neurosurgeon's intra-operative decision-making consist mostly of pre-operative imaging techniques such as MRI or MRA, which cannot cater to intra-operative changes in field of view. For a while now, spinal cord surgeons have adopted ultrasound and its submodalities such as Doppler and CEUS as intra-operative techniques, given their many benefits such as real-time feedback, mobility and ease of use. However, for highly vascularized lesions such as hemangioblastomas, which contain up to capillary-level microvasculature, having access to higher-resolution intra-operative vascular imaging could potentially be highly beneficial. µDoppler-imaging is a new imaging modality especially fit for high-resolution hemodynamic imaging. Over the last decade, µDoppler-imaging has emerged as a high-resolution, contrast-free sonography-based technique which relies on High-Frame-Rate (HFR)-ultrasound and subsequent Doppler processing. In contrast to conventional millimeter-scale (Doppler) ultrasound, the µDoppler technique has a higher sensitivity to detect slow flow in the entire field-of-view which allows for unprecedented visualization of blood flow down to sub-millimeter resolution. In contrast to CEUS, µDoppler is able to image high-resolution details continuously, without being contrast bolus-dependent. Previously, our team has demonstrated the use of this technique in the context of functional brain mapping during awake brain tumor resections and surgical resections of cerebral arteriovenous malformations (AVM). However, the application of µDoppler-imaging in the context of the spinal cord has remained restricted to a handful of mostly pre-clinical animal studies. Here we describe the first application of µDoppler-imaging in the case of a patient with two thoracic spinal hemangioblastomas. We demonstrate how µDoppler is able to identify intra-operatively and with high-resolution, hemodynamic features of the lesion. In contrast to pre-operative MRA, µDoppler could identify intralesional vascular details, in real-time during the surgical procedure. Additionally, we show highly detailed post-resection images of physiological human spinal cord anatomy. Finally, we discuss the necessary future steps to push µDoppler to reach actual clinical maturity.

5.
J Neurosurg Case Lessons ; 4(19)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36345205

RESUMO

OBJECTIVE: Given the high-risk nature of arteriovenous malformation (AVM) resections, accurate pre- and intraoperative imaging of the vascular morphology is a crucial component that may contribute to successful surgical results. Surprisingly, current gold standard imaging techniques for surgical guidance of AVM resections are mostly preoperative, lacking the necessary flexibility to cater to intraoperative changes. Micro-Doppler imaging is a unique high-resolution technique relying on high frame rate ultrasound and subsequent Doppler processing of microvascular hemodynamics. In this paper the authors report the first application of intraoperative, coregistered magnetic resonance/computed tomograpy, micro-Doppler imaging during the neurosurgical resection of an AVM in the parietal lobe. OBSERVATIONS: The authors applied intraoperative two-dimensional and three-dimensional (3D) micro-Doppler imaging during resection and were able to identify key anatomical features including draining veins, supplying arteries and microvasculature in the nidus itself. Compared to the corresponding preoperative 3D-digital subtraction angiography (DSA) image, the micro-Doppler images could delineate vascular structures and visualize hemodynamics with higher, submillimeter scale detail, even at significant depths (>5 cm). Additionally, micro-Doppler imaging revealed unique microvascular morphology of surrounding healthy vasculature. LESSONS: The authors conclude that micro-Doppler imaging in its current form has clear potential as an intraoperative counterpart to preoperative contrast-dependent DSA, and the microvascular details it provides could build new ground to further study cerebrovascular pathophysiology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...