Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pol J Radiol ; 86: e93-e101, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33758634

RESUMO

PURPOSE: Anatomical variants of the long head of the biceps (LHB) and diseases of the rotator interval structures may contribute to shoulder instability. The rotator interval and the LHB tendon are closely associated anatomic structures that confer stability to the shoulder. Anatomical variants around the origins of the long head of the biceps (LHB) are reported to occur with a frequency of 1.9-7.4%. In the past years, many authors have proposed different approaches for the identification and characterization of LHB and rotators interval. Magnetic resonance (MR) arthrography is considered the reference standard in imaging to diagnose superior shoulder diseases. However, few authors have analysed the anatomical variants and the relation between those and shoulder instability. This study aimed to identify the frequency of variants observed during arthroscopic shoulder surgeries, and to classify them based on the Dierickx classification system. MATERIAL AND METHODS: In 326 MR arthrograms we investigated the incidence of LHB anatomical variations and their association with shoulder diseases. RESULTS: We found 252/326 (77.3%) cases of LHB free, 40/326(12.26%) cases of LHB adherent, 31/326(9.50%) cases of mesotenon, and 3/326(0.9%) cases of split biceps. The prevalence of rotator interval synovitis in the mesotenon group was greater than in the LHB-free group. Moreover, in the LHB-adherent group we observed increased incidence of sublabral recess and SLAP lesions compared with the LHB-free group. CONCLUSIONS: MR-arthrography is useful in the evaluation of superior shoulder structures. A relationship exists between LHB anomalies and superior shoulder instability.

2.
Acta Biomed ; 89(1-S): 124-137, 2018 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-29350642

RESUMO

The correct management of acute, subacute and overuse-related elbow pathologies represents a challenging diagnostic and therapeutic problem. While major trauma frequently requires a rapid surgical intervention, subluxation and minor trauma allow taking more time for diagnostics and planning the correct elective treatment after careful clinical and radiological investigation. In these conditions, communication between orthopaedic surgeon and radiologist allow to create a detailed radiology report, tailored to the patient's and surgeon's needs and optimal to plan proper management. Imaging technique as X-Ray, CT, US, MRI, CTA and MRA all belong to the radiologist's portfolio in elbow diagnostics. Detailed knowledge of elbow pathology and its classification and of the possibilities and limits of each imaging technique is of crucial importance to reach the correct diagnosis efficiently. The aim of this review is to present the most frequent elbow pathologies and suggest a suitable diagnostic approach for each of them.


Assuntos
Transtornos Traumáticos Cumulativos/diagnóstico por imagem , Lesões no Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Luxações Articulares/diagnóstico por imagem , Instabilidade Articular/etiologia , Instabilidade Articular/terapia , Cotovelo de Tenista/diagnóstico por imagem
3.
Joints ; 2(3): 137-40, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25606557

RESUMO

Magnetic resonance imaging (MRI) is the gold standard method for non-invasive assessment of joint cartilage, providing information on the structure, morphology and molecular composition of this tissue. There are certain minimum requirements for a MRI study of cartilage tissue: machines with a high magnetic field (> 1.5 Tesla); the use of surface coils; and the use of T2-weighted, proton density-weighted fast-spin echo (T2 FSE-DP) and 3D fat-suppressed T1-weighted gradient echo (3D-FS T1W GRE) sequences. For better contrast between the different joint structures, MR arthography is a method that can highlight minimal fibrillation or fractures of the articular surface and allow evaluation of the integrity of the native cartilage-repair tissue interface. To assess the biochemical composition of cartilage and cartilage repair tissue, various techniques have been proposed for studying proteoglycans [dGEMRIC, T1rho mapping, sodium (23Na) imaging MRI, etc.], collagen, and water distribution [T2 mapping, "magnetisation transfer contrast", diffusion-weighted imaging (DWI), and so on]. Several MRI classifications have been proposed for evaluating the processes of joint degeneration (WORMS, BLOKS, ICRS) and post-surgical maturation of repair tissue (MOCART, 3D MOCART). In the future, isotropic 3D sequences set to improve image quality and facilitate the diagnosis of disorders of articular structures adjacent to cartilage.

4.
Arthrosc Tech ; 2(1): e9-e14, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23767005

RESUMO

We report the use of the double-pulley technique for arthroscopic fixation of the bony PASTA (partial articular surface tendon avulsion) lesion. Arthroscopic examination documented a 15-mm-long and 8-mm-wide comminuted bony avulsion with 2 main fragments. Two double-loaded suture anchors were placed with a transtendinous technique at the anterior and posterior edges of the lesion respecting the tendon insertion to the avulsed fragment. The medial sutures were retrieved through the intact supraspinatus tendon medially to the fracture. The sutures were initially coupled in a double-pulley configuration generating 2 sutures oriented from anterior to posterior; then a simple suture for each anchor oriented from medial to lateral was obtained. At the end of the procedure, the adequacy of reduction and stability of the fragments were confirmed. At 2 months from surgery, radiographic healing of the fracture was noted and integrity of the supraspinatus tendon insertion to the footprint was confirmed by arthro-magnetic resonance imaging, with full recovery of daily activities and complete active range of motion confirmed at 6 and 12 months. The double-pulley technique allows optimal reduction of bony fragments and reconstruction of normal footprint anatomy even in comminuted fractures. Moreover, it creates a waterproof reduction of the fragments, protecting the fracture site from synovial fluid.

5.
Eur Radiol ; 19(5): 1273-9, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19153745

RESUMO

Foreign bodies (FBs) retained in the soft tissues are a common reason for medical consultation, and usually consist of wooden or metal splinters or glass shards. Failure to remove foreign bodies is likely to give rise to acute or late complications, such as allergies, inflammation or infection, that may be severe. The surgical removal of an FB is invasive, costly and technically challenging. The procedure may fail in some cases and carries the risk of complications. Our study describes a technique for the ultrasound-guided removal of an FB, devised from our experience, and demonstrates its advantages over the standard surgical procedure. Sixty-two patients (43 males and 19 females aged from 9 to 65 years, median age 31 years) presented at our institution between October 2005 and June 2008 with suspected foreign bodies retained in the soft tissues of various body districts. Radiographic and/or ultrasound diagnosis was established by a radiologist expert in musculoskeletal sonography. The same radiologist helped by a nurse subsequently undertook the ultrasound-guided removal in the outpatient's clinic according to the technique described in the paper. ATL 5000 and PHILIPS iu22 ultrasound systems were used with high-frequency linear-array probes, sterile material, local anaesthetic (lidocaine 2%), scapels and surgical forceps. Antibiotic prophylaxis with amoxicillin and clavulanic acid were prescribed to all patients for 7 days after the procedure. Ninety-five FBs (39 glass, 35 metal, 17 vegetable, 2 plastic, 2 stone) were successfully removed under ultrasound guidance in all patients and the procedure took between 15 and 30 min. No complications arose either during or after the procedure. Seventy-five skin incisions were made and the wounds closed with Steri-Strips in 73/75 cases, whereas skin sutures were used in 2/75 cases. No complications arose either during or after the procedure. Ultrasound-guided removal of an FB retained in the soft tissues is a good alternative to surgery as is its relatively straightforward, inexpensive, repeatable and carries a low risk of complications. In addition, failure to remove an FB does not preclude traditional surgical removal. The advantages of this real-time procedure and the use of small instruments minimize bleeding time and avoid injury to surrounding structures. Patient compliance is enhanced by the fact that the procedure has little or no aesthetic impact. These encouraging results suggest ultrasound-guided removal as a first-choice procedure for the extraction of foreign bodies.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Operatórios/métodos , Suturas , Resultado do Tratamento
6.
Cases J ; 2: 9320, 2009 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-20062643

RESUMO

Magnetic Resonance arthrography is considered the gold standard imaging technique for the study of shoulder instability and tendon tears.We describe an image artefact, characterized by decreased signal intensity of the paramagnetic gadolinium chelate contrast agent during a shoulder Magnetic Resonance arthrography, attributable to an incorrect concentration which does not cause evident capsular damage and is completely absorbed after 48 h from the administration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...