Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mol Vis ; 23: 753-764, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29123364

RESUMO

Purpose: To explore the optimal lenticule storage conditions that maintain lenticule integrity and clarity. Methods: A total of 99 lenticules obtained from myopic patients undergoing small incision lenticule extraction (SMILE) were divided into four combinations for short-term storage conditions: PBS, Dulbecco's Modified Eagle's Medium (DMEM), Optisol GS, or anhydrous glycerol. Two thirds of the lenticules were further stored for 4 weeks under eight different conditions. Clarity evaluation with transmittance measurements, cell-death assays with terminal deoxynucleotidyl transferase-mediated nick end labeling assay (TUNEL), collagen fibril spacing and necrotic response assessed with transmission electron microscopy (TEM), and immunohistochemistry analysis for human leukocyte antigens (HLAs) and CD45 for immunogenicity, and matrix metalloproteinase (MMP)-2 for keratocyte response, were undertaken at baseline, 48 h (short term), and 4 weeks (long term). Results: The TUNEL and immunogenicity results were comparable among the groups. The mean percentage of TUNEL-positive cells across all groups was 24.3% ± 11.8% and 62.9% ± 20.7% at the 48 h and 4 week time points, respectively. HLA-ABC+, HLA-DR+, and CD45+ cells were extremely rare, and MMP-2 expression ranged from non-detectable to minimal, under all conditions at all time points. Transmittance at 4 weeks was significantly different among groups with the greatest maintenance of clarity seen in the lenticules stored initially in DMEM at 4 °C for 48 h followed by cryopreservation in serum-free medium or glycerol at 4 °C followed by storage at room temperature. At TEM analysis at 4 weeks, the lenticules cryopreserved in liquid nitrogen, regardless of storage solutions, had significantly narrower inter-fibrillar distance than controls, while glycerol-preserved lenticules, at either room temperature or -80 °C, maintained the inter-fibrillar distance. Conclusions: Clarity, structural integrity, and low immunogenicity under various conditions, at 4 °C or room temperature for short-term storage, offer encouragement for lenticule storage. It can be undertaken without access to s specialized and potentially expensive laboratory setup at least within the first 48 h before transportation to larger facilities for long-term storage.


Assuntos
Substância Própria , Cirurgia da Córnea a Laser , Criopreservação , Miopia/cirurgia , Reimplante , Preservação de Tecido , Adulto , Morte Celular , Substância Própria/fisiologia , Antígenos HLA/metabolismo , Humanos , Marcação In Situ das Extremidades Cortadas , Antígenos Comuns de Leucócito/metabolismo , Metaloproteinase 2 da Matriz/metabolismo , Microscopia Eletrônica de Transmissão , Soluções para Preservação de Órgãos , Doadores de Tecidos , Coleta de Tecidos e Órgãos
2.
Sci Rep ; 6: 24352, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-27090745

RESUMO

The introduction of femtosecond laser assisted cataract surgery (FLACS) is a paradigm changing approach in cataract surgery, the most commonly performed surgical procedure. FLACS has the potential to optimize the creation of an anterior lens capsulotomy, a critical step in accessing the cataractous lens. The merits of using a laser instead of a manual approach include a potentially more circular, consistent, and stronger aperture. In this study we demonstrated for the first time in both a porcine and human experimental setting that with a low energy, high repetition FLACS system, that a circular, smooth and strong capsulotomy was achievable. While there was no demonstrable difference in the resistance to rupture before or after the removal of the nucleus, larger capsulotomies had an increase in tensile strength. The LDV Z8 system appeared to create circular, rupture-resistant and smooth capsulotomies in both porcine and more importantly human globes.


Assuntos
Catarata/terapia , Terapia a Laser , Cristalino/cirurgia , Capsulotomia Posterior , Animais , Catarata/patologia , Extração de Catarata/métodos , Olho/patologia , Olho/efeitos da radiação , Humanos , Cristalino/efeitos da radiação , Procedimentos Cirúrgicos Oftalmológicos/métodos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA