Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Med Robot ; 9(3): 280-97, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22588805

RESUMO

BACKGROUND: Telesurgery delivers surgical care to a 'remote' patient by means of robotic manipulators. When accurate positioning of the surgeon's tool is required, as in microsurgery, physiological tremor causes unwanted imprecision during a surgical operation. Accurate estimation/compensation of physiological tremor in teleoperation systems has been shown to improve performance during telesurgery. METHOD: A new control architecture is proposed for estimation and compensation of physiological tremor in the presence of communication time delays. This control architecture guarantees stability with satisfactory transparency. In addition, the proposed method can be used for applications that require modifications in transmitted signals through communication channels. Stability of the bilateral tremor-compensated teleoperation is preserved by extending the bilateral teleoperation to the equivalent trilateral Dual-master/Single-slave teleoperation. The bandlimited multiple Fourier linear combiner (BMFLC) algorithm is employed for real-time estimation of the operator's physiological tremor. RESULTS: Two kinds of stability analysis are employed. In the model-base controller, Llewellyn's Criterion is used to analyze the teleoperation absolute stability. In the second method, a nonmodel-based controller is proposed and the stability of the time-delayed teleoperated system is proved by employing a Lyapunov function. Experimental results are presented to validate the effectiveness of the new control architecture. The tremorous motion is measured by accelerometer to be compensated in real time. In addition, a Needle-Insertion setup is proposed as a slave robot for the application of brachytherapy, in which the needle penetrates in the desired position. The slave performs the desired task in two classes of environments (free motion of the slave and in the soft tissue). CONCLUSION: Experiments show that the proposed control architecture effectively compensates the user's tremorous motion and the slave follows only the master's voluntary motion in a stable manner.


Assuntos
Robótica/métodos , Cirurgia Assistida por Computador/métodos , Tremor/fisiopatologia , Algoritmos , Sistemas Computacionais , Humanos , Microcirurgia/instrumentação , Microcirurgia/métodos , Microcirurgia/estatística & dados numéricos , Modelos Anatômicos , Robótica/instrumentação , Robótica/estatística & dados numéricos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/estatística & dados numéricos , Interface Usuário-Computador
2.
ISA Trans ; 52(2): 268-77, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23146205

RESUMO

A novel trilateral control architecture for the Dual-master/Single-slave teleoperation is proposed in this paper. This framework has been used in surgical training and rehabilitation applications. In this structure, the slave motion has been controlled by weighted summation of signals transmitted by the operator referring to task control authority through the dominance factors. The nonlinear dynamics for telemanipulators are considered which were considered as disregarded issues in previous studies of this field. Bounded variable time-delay has been considered which affects the transmitted signals in the communication channels. Two types of controllers have been offered and an appropriate stability analysis for each controller has been demonstrated. The first controller includes Proportional with dissipative gains (P+d). The second one contains Proportional and Derivative with dissipative gains (PD+d). In both cases, the stability of the trilateral control framework is preserved by choosing appropriate controller's gains. It is shown that these controllers attempt to coordinate the positions of telemanipulators in the free motion condition. The stability of the Dual-master/Single-slave teleoperation has been proved by an appropriate Lyapunov like function and the stability conditions have been studied. In addition the proposed PD+d control architecture is modified for trilateral teleoperation with internet communication between telemanipulators that caused such communication complications as packet loss, data duplication and swapping. A number of experiments have been conducted with various levels of dominance factor to validate the effectiveness of the new control architecture.


Assuntos
Algoritmos , Retroalimentação , Modelos Teóricos , Dinâmica não Linear , Telemedicina/métodos , Interface Usuário-Computador , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA