Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 26(22): 16261-16272, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38804603

RESUMO

To achieve scalable and economically viable green hydrogen (H2) production, the photocatalytic and piezocatalytic processes are promising methods. The key to successful overall water splitting (OWS) for H2 production in these processes is using suitable semiconductor catalysts with appropriate band edge potentials, efficient optical absorption, higher mechanical flexibility, and piezoelectric coefficients. Thus, we explore the bismuth nitride (BiN) monolayer using density functional theory simulations, revealing intriguing catalytic properties. The BiN monolayer is a semiconductor with an indirect electronic bandgap (Eg) of 2.08 eV and displays excellent visible light absorption (approximately 105 cm-1). Detailed analyses show that the band edges satisfy the redox potential for photocatalytic OWS via biaxial strain engineering and pH variation. Notably, the solar to hydrogen conversion efficiency (ηSTH) for the BiN monolayer can reach 17.18%, which exceeds the 10% efficiency limit of photocatalysts for economical green H2 production. The obtained in-plane piezoelectric coefficient of e11 = 16.18 ŠC m-1 is superior to widely studied 2D materials. Moreover, the generated piezopotential under oscillatory strain stands at 28.34 V, which can initiate the water redox reaction via the piezocatalytic mechanism. This originates from the mechanical flexibility coupled with higher piezoelectric coefficients. The result highlights the BiN monolayer's potential application in photocatalytic, piezocatalytic, and photo-piezo-catalytic OWS.

2.
Chem Sci ; 14(10): 2547-2552, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36908941

RESUMO

Organic molecules with an active dipole moment have a natural propensity to align in an antiparallel fashion in the solid state, resulting in zero macroscopic polarization. This primary limitation makes the material unresponsive to switching with electric fields, mechanical forces, and to intense laser light. A single-component organic material that bestows macroscopic dipole-driven electro-mechanical and optical functions, e.g., piezoelectric, ferroelectric and nonlinear optical (NLO) activity, is unprecedented due to the design challenges imparted by crystal symmetry and dipole orientations. Herein we report a crystalline organic material that self-assembles with a polar order (P 1), and is endowed with a high piezoelectric coefficient (d 33-47 pm V-1), as well as ferroelectric and Debye-type relaxor properties. In addition, it shows second harmonic generation (SHG) activity, which is more than five times that of the benchmark potassium dihydrogen phosphate. Piezoelectric force microscopy (PFM) images validated electro-mechanical deformations. Piezoresponse force spectroscopy (PFS) studies confirmed a signature butterfly-like amplitude and a phase loop. To the best of our knowledge, this is the first report of a folded supramolecular π-system that manifests unidirectionally oriented dipoles and exhibits piezoelectricity, ferroelectricity, and has excellent ability to generate second harmonic light. These findings can herald new design possibilities based on folded architectures to explore opto-, electro- and mechano-responsive multifaceted functions.

3.
Cardiovasc Eng Technol ; 13(6): 840-856, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35391657

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) is the most common congenital cardiac malformation, which had been treated off-label by transcatheter aortic valve replacement (TAVR) procedure for several years, until its recent approval by the Food and Drug Administration (FDA) and Conformité Européenne (CE) to treat BAVs. Post-TAVR complications tend to get exacerbated in BAV patients due to their inherent aortic root pathologies. Globally, due to the paucity of randomized clinical trials, clinicians still favor surgical AVR as the primary treatment option for BAV patients. While this warrants longer term studies of TAVR outcomes in BAV patient cohorts, in vitro experiments and in silico computational modeling can be used to guide the surgical community in assessing the feasibility of TAVR in BAV patients. Our goal is to combine these techniques in order to create a modeling framework for optimizing pre-procedural planning and minimize post-procedural complications. MATERIALS AND METHODS: Patient-specific in silico models and 3D printed replicas of 3 BAV patients with different degrees of post-TAVR paravalvular leakage (PVL) were created. Patient-specific TAVR device deployment was modeled in silico and in vitro-following the clinical procedures performed in these patients. Computational fluid dynamics simulations and in vitro flow studies were performed in order to obtain the degrees of PVL in these models. RESULTS: PVL degree and locations were consistent with the clinical data. Cross-validation comparing the stent deformation and the flow parameters between the in silico and the in vitro models demonstrated good agreement. CONCLUSION: The current framework illustrates the potential of using simulations and 3D printed models for pre-TAVR planning and assessing post-TAVR complications in BAV patients.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Simulação por Computador , Hidrodinâmica , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
4.
J Cardiovasc Transl Res ; 15(4): 834-844, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34859367

RESUMO

Bicuspid aortic valve (BAV), the most common congenital valvular abnormality, generates asymmetric flow patterns and increased stresses on the leaflets that expedite valvular calcification and structural degeneration. Recently adapted for use in BAV patients, TAVR demonstrates promising performance, but post-TAVR complications tend to get exacerbated due to BAV anatomical complexities. Utilizing patient-specific computational modeling, we address some of these complications. The degree and location of post-TAVR PVL was assessed, and the risk of flow-induced thrombogenicity was analyzed in 3 BAV patients - using older generation TAVR devices that were implanted in these patients, and compared them to the performance of the newest generation TAVR devices using in silico patient models. Significant decrease in PVL and thrombogenic potential was observed after implantation of the newest generation device. The current work demonstrates the potential of using simulations in pre-procedural planning to assess post-TAVR complications, and compare the performance of different devices to achieve better clinical outcomes. Patient-specific computational framework to assess post-transcatheter bicuspid aortic valve replacement paravalvular leakage and flow-induced thrombogenic complications and compare device performances.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Modelagem Computacional Específica para o Paciente , Simulação por Computador , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
5.
J Phys Condens Matter ; 33(38)2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34229302

RESUMO

Using first-principles calculations, we predict that the two-dimensional (2D) monolayers of NbP with the buckled honeycomb-like and puckered tetragonal structure can be obtained from the (110) and (001) orientations, respectively, of its bulk crystal structure. The electronic properties of these monolayers are spectacularly different as tetragonal lattice is metallic whereas the honeycomb-like lattice (h-NbP) is a semiconductor and exhibits intrinsic ferroelectricity originating from a raresd2-sp2hybridization. The shift current bulk photovoltaic effect (BPVE) is systematically investigated in the h-NbP monolayer (1.21 Å thickness) using the Wannier interpolation method. Strong absorption of visible light at ∼2 eV and a large 3D shift current of ∼180µA V-2is obtained which is attributed to the partial delocalization of Bloch states due tosd2-sp2hybridization. We compare the shift current response of h-NbP monolayer with that of some previously reported bulk ferroelectrics and 2D monolayers, suggesting that h-NbP monolayer can yield a large shift current at an ultimate thickness and is a promising 2D material for the BPVE application under the visible light. Strain effect is also investigated, revealing that the h-NbP monolayer is dynamically stable up to a strain limit of ±3%, and the shift current increases by ∼9% at a compressive strain of -3% as the Bloch states are more delocalized due to the strengthening ofsd2-sp2hybridization. The results presented in this study can pave the paths to fabricate the 2D monolayered structures of NbP, and realize the BPVE based next-generation solar cells of h-NbP monolayer.

6.
Ann Biomed Eng ; 49(2): 627-641, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32804291

RESUMO

Congenital bicuspid aortic valve (BAV) consists of two fused cusps and represents a major risk factor for calcific valvular stenosis. Herein, a fully coupled fluid-structure interaction (FSI) BAV model was developed from patient-specific magnetic resonance imaging (MRI) and compared against in vivo 4-dimensional flow MRI (4D Flow). FSI simulation compared well with 4D Flow, confirming direction and magnitude of the flow jet impinging onto the aortic wall as well as location and extension of secondary flows and vortices developing at systole: the systolic flow jet originating from an elliptical 1.6 cm2 orifice reached a peak velocity of 252.2 cm/s, 0.6% lower than 4D Flow, progressively impinging on the ascending aorta convexity. The FSI model predicted a peak flow rate of 22.4 L/min, 6.7% higher than 4D Flow, and provided BAV leaflets mechanical and flow-induced shear stresses, not directly attainable from MRI. At systole, the ventricular side of the non-fused leaflet revealed the highest wall shear stress (WSS) average magnitude, up to 14.6 Pa along the free margin, with WSS progressively decreasing towards the belly. During diastole, the aortic side of the fused leaflet exhibited the highest diastolic maximum principal stress, up to 322 kPa within the attachment region. Systematic comparison with ground-truth non-invasive MRI can improve the computational model ability to reproduce native BAV hemodynamics and biomechanical response more realistically, and shed light on their role in BAV patients' risk for developing complications; this approach may further contribute to the validation of advanced FSI simulations designed to assess BAV biomechanics.


Assuntos
Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Feminino , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Estresse Mecânico
7.
Biomech Model Mechanobiol ; 19(5): 1725-1740, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32095912

RESUMO

Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure that provides an effective alternative to open-heart surgical valve replacement for treating advanced calcific aortic valve disease patients. However, complications, such as valve durability, device migration, paravalvular leakage (PVL), and thrombogenicity may lead to increased overall post-TAVR morbidity and mortality. A series of numerical studies involving a self-expandable TAVR valve were performed to evaluate these complications. Structural studies were performed with finite element (FE) analysis, followed by computational fluid dynamics (CFD) simulations, and fluid-structure interaction (FSI) analysis. The FE analysis was utilized to study the effect of TAVR valve implantation depth on valve anchorage in the Living Heart Human Model, which is capable of simulating beating heart during repeated cardiac cycles. The TAVR deployment cases where no valve migration was observed were then used to calculate the post-deployment thrombogenic potential via CFD simulations. FSI analysis followed to further assess the post-deployment TAVR hemodynamic performance for different implantation depths. The deployed valves PVL, geometric and effective orifice areas, and the leaflets structural and flow stress magnitudes were compared to determine the device optimal landing zone. The combined structural and hemodynamic analysis indicated that with the TAVR valve deployed at an aft ventricle position an optimal performance was achieved in the specific anatomy studied. Given the TAVR's rapid expansion to younger lower-risk patients, the comprehensive numerical methodology proposed here can potentially be used as a predictive tool for both procedural planning and valve design optimization to minimize the reported complications.


Assuntos
Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Hemodinâmica/fisiologia , Análise Numérica Assistida por Computador , Substituição da Valva Aórtica Transcateter , Fenômenos Biomecânicos , Simulação por Computador , Análise de Elementos Finitos , Humanos , Hidrodinâmica , Stents , Estresse Mecânico , Trombose/fisiopatologia
8.
Biomech Model Mechanobiol ; 19(2): 779, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31965351

RESUMO

This is to inform that the original article was published without the "Conflict of Interest" statement.

9.
J Phys Condens Matter ; 31(50): 505502, 2019 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-31470438

RESUMO

A large ferroelectric (FE) polarization and low bandgap are essential to improving the bulk photovoltaic response which is the generation of photocurrent in the polar non-centrosymmetric materials such as FE perovskite oxides. Among various perovskite oxides, Potassium Niobate (KNbO3, KNO) is a promising FE material for bulk photovoltaic applications as its bandgap and polarization can be tuned effectively by strain, doping, or by applying an electric field. In this work, using the density functional theory calculations, we present an insight into the strain engineering of polarization, band structure, and optical properties of the cubic (C), tetragonal (T), and orthorhombic (O) structures of KNO. The tensile and compressive strain under the triaxial, biaxial, and uniaxial conditions are applied along the direction parallel and perpendicular to the polar axis of KNO structures. We find that the bandgap decreases along with a substantial increment of polarization on the application of tensile strain along the direction parallel to the polar axis. In T (O) phase at +2% strain, the polarization increases by 18 µC cm-2 (14 µC cm-2) in triaxial, 26 µC cm-2 (16 µC cm-2) in biaxial, and 29 µC cm-2 (29 µC cm-2) in uniaxial conditions with a considerable decreasing of bandgap with respect to zero strain condition. Therefore, wisely applying the tensile strain along the direction parallel to the polar axis, the photovoltaic efficiency of KNO can be improved.

10.
J Phys Condens Matter ; 31(39): 395802, 2019 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-31195375

RESUMO

Spintronic functionality in ferromagnetic materials is a next-generation technique, to be used in data storage, high-frequency communications, and logic devices with minimum energy consumption. Ultra-low energy consumption in high-speed logic devices can be envisioned by inducing ferromagnetic behavior into room temperature multiferroic materials. However, there is a scarcity of room temperature multiferroic materials which have a definite spin degree of freedom. To fully exploit these technological challenges, we introduce the induced ferromagnetism in bismuth ferrite (BiFeO3, BFO) by doping transition metal (Cr, Ni, Co) elements. Our investigation initiates with the experimental study on chemically synthesized BiFe(1-x)M x O3 samples where x = 0.0625 (6.25%) and M = Cr, Ni and Co. Experimental findings are verified by theoretical simulation using density functional theory (DFT + U) and gauge including projector augmented wave (GIPAW) based calculation. All the experimental studies are done at room temperature while the theoretical verification using DFT is carried to understand the underlying mechanism behind the magnetic behavior of doped BiFeO3. It is done by optimizing the structural parameters comparable to the room temperature values. Microstructural and magnetic properties are studied using x-ray diffraction (XRD), transmission electron microscopy (TEM) and Vibrating sample magnetometer (VSM). All these experimental studies confirm the structural changes and induced ferromagnetism with doping. X-ray photoelectron spectroscopy (XPS) verified the reason behind this ferromagnetic property on the basis of oxygen vacancy content. Electron paramagnetic resonance (EPR) spectroscopy shows the tuning of Δg values due to enhanced magnetization. The density of states (DOS) calculations were performed on BFO (band-gap 1.89 eV) after structural optimization using DFT + U method, confirm our experimental findings. Magnetic moment values change drastically with doping elements (M), i.e. almost negligible for BFO (antiferromagnetic) to maximum (2.85 µ B/f.u.) for Ni-doped sample. We also compute the EPR g-tensor using GIPAW method to confirm the tuning of Δg values due to enhanced magnetization. These results can highlight the impact and importance of suitable transition element doping to induce the room temperature ferromagnetism in BiFeO3.

11.
Nanoscale ; 11(13): 6016-6022, 2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-30869095

RESUMO

The 1T phase of tantalum disulfide (1T-TaS2) possesses a variety of charge-density-wave (CDW) orders, and as a result, it attracts an increasing amount of academic and technological interest. Researchers have devoted tremendous efforts towards understanding the impacts of doping, alloying, intercalation or other triggering agents on its charge density wave orders. In this work, we demonstrate that incorporating potassium chloride (KCl) during chemical vapor deposition (CVD) of TaS2 can control the phase (1T, 2H or metal nanowires) via the intercalation of potassium ions (K+) between TaS2 layers. Finally, we demonstrate that K+ not only impacts the structure during synthesis but also strongly impacts the CDW phase transition as a function of temperature, increasing the nearly commensurate (NCCDW) to commensurate (CCDW) transition to just below room temperature.

12.
Biomech Model Mechanobiol ; 18(2): 435-451, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30460623

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical valve replacement in high-risk patients afflicted by severe aortic stenosis. Despite newer-generation devices enhancements, post-procedural complications such as paravalvular leakage (PVL) and related thromboembolic events have been hindering TAVR expansion into lower-risk patients. Computational methods can be used to build and simulate patient-specific deployment of transcatheter aortic valves (TAVs) and help predict the occurrence and degree of PVL. In this study finite element analysis and computational fluid dynamics were used to investigate the influence of procedural parameters on post-deployment hemodynamics on three retrospective clinical cases affected by PVL. Specifically, TAV implantation depth and balloon inflation volume effects on stent anchorage, degree of paravalvular regurgitation and thrombogenic potential were analyzed for cases in which Edwards SAPIEN and Medtronic CoreValve were employed. CFD results were in good agreement with corresponding echocardiography data measured in patients in terms of the PVL jets locations and overall PVL degree. Furthermore, parametric analyses demonstrated that positioning and balloon over-expansion may have a direct impact on the post-deployment TAVR performance, achieving as high as 47% in PVL volume reduction. While the model predicted very well clinical data, further validation on a larger cohort of patients is needed to verify the level of the model's predictions in various patient-specific conditions. This study demonstrated that rigorous and realistic patient-specific numerical models could potentially serve as a valuable tool to assist physicians in pre-operative TAVR planning and TAV selection to ultimately reduce the risk of clinical complications.


Assuntos
Valva Aórtica/cirurgia , Simulação por Computador , Substituição da Valva Aórtica Transcateter , Velocidade do Fluxo Sanguíneo/fisiologia , Hemodinâmica/fisiologia , Humanos , Fluxo Sanguíneo Regional/fisiologia , Stents , Estresse Mecânico , Trombose/patologia
13.
Expert Rev Med Devices ; 15(11): 771-791, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30318937

RESUMO

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) has emerged as an effective minimally-invasive alternative to surgical valve replacement in medium- to high-risk, elderly patients with calcific aortic valve disease and severe aortic stenosis. The rapid growth of the TAVR devices market has led to a high variety of designs, each aiming to address persistent complications associated with TAVR valves that may hamper the anticipated expansion of TAVR utility. AREAS COVERED: Here we outline the challenges and the technical demands that TAVR devices need to address for achieving the desired expansion, and review design aspects of selected, latest generation, TAVR valves of both clinically-used and investigational devices. We further review in detail some of the up-to-date modeling and testing approaches for TAVR, both computationally and experimentally, and additionally discuss those as complementary approaches to the ISO 5840-3 standard. A comprehensive survey of the prior and up-to-date literature was conducted to cover the most pertaining issues and challenges that TAVR technology faces. EXPERT COMMENTARY: The expansion of TAVR over SAVR and to new indications seems more promising than ever. With new challenges to come, new TAV design approaches, and materials used, are expected to emerge, and novel testing/modeling methods to be developed.


Assuntos
Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Animais , Valva Aórtica/patologia , Estenose da Valva Aórtica/terapia , Calcinose/terapia , Próteses Valvulares Cardíacas , Humanos , Uso Off-Label , Polímeros/química , Substituição da Valva Aórtica Transcateter/efeitos adversos
14.
J Biomech Eng ; 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-30029207

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical aortic valve replacement (SAVR) in high-risk elderly patients with calcified aortic valve disease. All currently FDA-approved TAVR devices use tissue valves that were adapted to but not specifically designed for TAVR use. Emerging clinical evidence indicates that these valves may get damaged during crimping and deployment- leading to valvular calcification, thrombotic complications, and limited durability. This impedes the expected expansion of TAVR to lower-risk and younger patients. Viable polymeric valves have the potential to overcome such limitations. We have developed a polymeric SAVR valve, which was optimized to reduce leaflet stresses and offer a thromboresistance profile similar to that of a tissue valve. This study compares the polymeric SAVR valve's hemodynamic performance and mechanical stresses to a new version of the valve- specifically designed for TAVR. Fluid-structure interaction (FSI) models were utilized and the valves' hemodynamics, flexural stresses, strains, orifice area, and wall shear stresses were compared. The TAVR valve had 42% larger opening area and 27% higher flow rate versus the SAVR valve, while wall shear stress distribution and mechanical stress magnitudes were of the same order, demonstrating the enhanced performance of the TAVR valve prototype. The TAVR valve FSI simulation and Vivitro pulse duplicator experiments were compared in terms of the leaflets' kinematics and the effective orifice area. The numerical methodology presented can be further used as a predictive tool for valve design optimization for enhanced hemodynamics and durability.

15.
Artif Organs ; 40(12): E292-E304, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27911025

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a life-saving and effective alternative to surgical valve replacement in high-risk, elderly patients with severe calcific aortic stenosis. Despite its early promise, certain limitations and adverse events, such as suboptimal placement and valve migration, have been reported. In the present study, it was aimed to evaluate the effect of various TAVR deployment locations on the procedural outcome by assessing the risk for valve migration. The deployment of a balloon-expandable Edwards SAPIEN valve was simulated via finite element analysis in a patient-specific calcified aortic root, which was reconstructed from CT scans of a retrospective case of valve migration. The deployment location was parametrized in three configurations and the anchorage was quantitatively assessed based on the contact between the stent and the native valve during the deployment and recoil phases. The proximal deployment led to lower contact area between the native leaflets and the stent which poses higher risk for valve migration. The distal and midway positions resulted in comparable outcomes, with the former providing a slightly better anchorage. The approach presented might be used as a predictive tool for procedural planning in order to prevent prosthesis migration and achieve better clinical outcomes.


Assuntos
Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/cirurgia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Aorta/anatomia & histologia , Valva Aórtica/cirurgia , Simulação por Computador , Análise de Elementos Finitos , Humanos , Masculino , Modelos Anatômicos , Modelos Biológicos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
16.
Nat Mater ; 15(11): 1166-1171, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27571451

RESUMO

The spectrum of two-dimensional (2D) and layered materials 'beyond graphene' offers a remarkable platform to study new phenomena in condensed matter physics. Among these materials, layered hexagonal boron nitride (hBN), with its wide bandgap energy (∼5.0-6.0 eV), has clearly established that 2D nitrides are key to advancing 2D devices. A gap, however, remains between the theoretical prediction of 2D nitrides 'beyond hBN' and experimental realization of such structures. Here we demonstrate the synthesis of 2D gallium nitride (GaN) via a migration-enhanced encapsulated growth (MEEG) technique utilizing epitaxial graphene. We theoretically predict and experimentally validate that the atomic structure of 2D GaN grown via MEEG is notably different from reported theory. Moreover, we establish that graphene plays a critical role in stabilizing the direct-bandgap (nearly 5.0 eV), 2D buckled structure. Our results provide a foundation for discovery and stabilization of 2D nitrides that are difficult to prepare via traditional synthesis.

17.
Thromb Res ; 140: 110-117, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26938158

RESUMO

Continuous flow ventricular assist devices (cfVADs) while effective in advanced heart failure, remain plagued by thrombosis related to abnormal flows and elevated shear stress. To limit cfVAD thrombosis, patients utilize complex anti-thrombotic regimens built upon a foundation of aspirin (ASA). While much data exists on ASA as a modulator of biochemically-mediated platelet activation, limited data exists as to the efficacy of ASA as a means of limiting shear-mediated platelet activation, particularly under elevated shear stress common within cfVADs. We investigated the ability of ASA (20, 25 and 125 µM) to limit shear-mediated platelet activation under conditions of: 1) constant shear stress (30 dynes/cm(2) and 70 dynes/cm(2)); 2) dynamic shear stress, and 3) initial high shear exposure (70 dynes/cm(2)) followed by low shear exposure - i.e. a platelet sensitization protocol, utilizing a hemodynamic shearing device providing uniform shear stress in vitro. The efficacy of ASA to limit platelet activation mediated via passage through a clinical cfVAD system (DeBakey Micromed) in vitro was also studied. ASA reduced platelet activation only under conditions of low shear stress (38% reduction compared to control, n=10, p<0.004), with minimal protection at higher shear stress and under dynamic conditions (n=10, p>0.5) with no limitation of platelet sensitization. ASA had limited ability (25.6% reduction in platelet activation rate) to modulate shear-mediated platelet activation induced via cfVAD passage. These findings, while performed under "deconstructed" non-clinical conditions by utilizing purified platelets alone in vitro, provide a potential contributory mechanistic explanation for the persistent thrombosis rates experienced clinically in cfVAD patients despite ASA therapy. An opportunity exists to develop enhanced pharmacologic strategies to limit shear-mediated platelet activation at elevated shear levels associated with mechanical circulatory support devices.


Assuntos
Aspirina/farmacologia , Coração Auxiliar/efeitos adversos , Ativação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Trombose/etiologia , Trombose/prevenção & controle , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Humanos , Estresse Mecânico
18.
Nat Commun ; 6: 7311, 2015 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-26088295

RESUMO

Vertical integration of two-dimensional van der Waals materials is predicted to lead to novel electronic and optical properties not found in the constituent layers. Here, we present the direct synthesis of two unique, atomically thin, multi-junction heterostructures by combining graphene with the monolayer transition-metal dichalcogenides: molybdenum disulfide (MoS2), molybdenum diselenide (MoSe2) and tungsten diselenide (WSe2). The realization of MoS2-WSe2-graphene and WSe2-MoS2-graphene heterostructures leads to resonant tunnelling in an atomically thin stack with spectrally narrow, room temperature negative differential resistance characteristics.

19.
Artigo em Inglês | MEDLINE | ID: mdl-26736255

RESUMO

Calcific aortic valve disease (CAVD) is a cardiovascular condition that causes the progressive narrowing of the aortic valve (AV) opening, due to the growth of bone-like deposits all over the aortic root (AR). Transcatheter aortic valve replacement (TAVR), a minimally invasive procedure, has recently become the only lifesaving solution for patients that cannot tolerate the standard surgical valve replacement. However, adverse effects, such as AR injury or paravalvular leakage (PVL), may occur as a consequence of a sub-optimal procedure, due to the presence of calcifications in situ. Additionally, the crimping required for delivering the valve via stenting may damage the valve. The aim of the present study is to comparatively assess the crimping mechanics of the commercialized Edwards SAPIEN valve and an alternative polymeric valve (Polynova, Inc) and to evaluate the effect of different TAVR deployment positions using patient-specific numerical models. The optimal deployment location for achieving better patient outcomes was calculated and based on the interactions between the TAVR stent and the native AR. Results demonstrated that the Polynova valve withstands the crimping process better than the SAPIEN valve. Furthermore, deployment simulations showed the role that calcifications deposits may play in the TAVR sub-optimal valve anchoring to the AV wall, leading to the presence of gaps that result in PVL.


Assuntos
Aorta/cirurgia , Posicionamento do Paciente , Substituição da Valva Aórtica Transcateter , Valva Aórtica/patologia , Estenose da Valva Aórtica/terapia , Calcinose/terapia , Análise de Elementos Finitos , Próteses Valvulares Cardíacas , Humanos , Modelos Biológicos , Stents
20.
Nano Lett ; 14(12): 6936-41, 2014 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-25383798

RESUMO

Heterogeneous engineering of two-dimensional layered materials, including metallic graphene and semiconducting transition metal dichalcogenides, presents an exciting opportunity to produce highly tunable electronic and optoelectronic systems. In order to engineer pristine layers and their interfaces, epitaxial growth of such heterostructures is required. We report the direct growth of crystalline, monolayer tungsten diselenide (WSe2) on epitaxial graphene (EG) grown from silicon carbide. Raman spectroscopy, photoluminescence, and scanning tunneling microscopy confirm high-quality WSe2 monolayers, whereas transmission electron microscopy shows an atomically sharp interface, and low energy electron diffraction confirms near perfect orientation between WSe2 and EG. Vertical transport measurements across the WSe2/EG heterostructure provides evidence that an additional barrier to carrier transport beyond the expected WSe2/EG band offset exists due to the interlayer gap, which is supported by theoretical local density of states (LDOS) calculations using self-consistent density functional theory (DFT) and nonequilibrium Green's function (NEGF).


Assuntos
Grafite/química , Membranas Artificiais , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Selênio/química , Compostos de Tungstênio/química , Condutividade Elétrica , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA