Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Entropy (Basel) ; 24(11)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36421514

RESUMO

The performance of cosmic-ray tomography systems is largely determined by their tracking accuracy. With conventional scintillation detector technology, good precision can be achieved with a small pitch between the elements of the detector array. Improving the resolution implies increasing the number of read-out channels, which in turn increases the complexity and cost of the tracking detectors. As an alternative to that, a scintillation plate detector coupled with multiple silicon photomultipliers could be used as a technically simple solution. In this paper, we present a comparison between two deep-learning-based methods and a conventional Center of Gravity (CoG) algorithm, used to calculate cosmic-ray muon hit positions on the plate detector using the signals from the photomultipliers. In this study, we generated a dataset of muon hits on a detector plate using the Monte Carlo simulation toolkit GEANT4. We demonstrate that two deep-learning-based methods outperform the conventional CoG algorithm by a significant margin. Our proposed algorithm, Fully Connected Network, produces a 0.72 mm average error measured in Euclidean distance between the actual and predicted hit coordinates, showing great improvement in comparison with CoG, which yields 1.41 mm on the same dataset. Additionally, we investigated the effects of different sensor configurations on performance.

2.
Phys Med ; 103: 127-137, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36302279

RESUMO

FLASH radiation therapy is a novel technique combining ultra-high dose rates (UHDR) with very short treatment times to strongly decrease normal tissue toxicity while preserving the anti-tumoral effect. However, the radiobiological mechanisms and exact conditions for obtaining the FLASH-effect are still under investigation. There are strong indications that parameters defining the beam structure, such as dose per pulse, instantaneous dose rate and pulse repetition frequency (PRF) are of importance. UHDR irradiations therefore come with dosimetric challenges, including both dose assessment and temporal ones. In this work, a first characterization of 6 real-time point scintillating dosimeters with 5 phosphors (Al2O3:C,Mg; Y2O3:Eu; Al2O3:C; (C38H34P2)MnBr4 and (C38H34P2)MnCl4, was performed in an UHDR pulsed electron beam. The dose rate independence of the calibration was tested by calibrating the detector at conventional and UHDR. Dose rate dependence was observed, however, further investigation, including intermediate dose rates, is needed. Linearity of the response with dose was tested by varying the number of pulses and a linearity with R2> 0.9989 was observed up to at least 200 Gy. Dose per pulse linearity was investigated by variation of the pulse length and SSD. All point scintillators showed saturation effects up to some extent and the instantaneous dose rate dependence was confirmed. A PRF dependence was observed for the Al2O3:C,Mg and Al2O3:C- based point scintillators. This was expected as the luminescence decay time of these materials exceeds the inter-pulse time.


Assuntos
Elétrons , Radiometria , Dosímetros de Radiação , Calibragem , Luminescência
3.
Med Phys ; 48(4): 1983-1995, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33587754

RESUMO

PURPOSE: Despite the physical benefits of protons over conventional photon radiation in cancer treatment, range uncertainties impede the ability to harness the full potential of proton therapy. While monitoring the proton range in vivo could reduce the currently adopted safety margins, a routinely applicable range verification technique is still lacking. Recently, phase-change nanodroplets were proposed for proton range verification, demonstrating a reproducible relationship between the proton range and generated ultrasound contrast after radiation-induced vaporization at 25°C. In this study, previous findings are extended with proton irradiations at different temperatures, including the physiological temperature of 37°C, for a novel nanodroplet formulation. Moreover, the potential to modulate the linear energy transfer (LET) threshold for vaporization by varying the degree of superheat is investigated, where the aim is to demonstrate vaporization of nanodroplets directly by primary protons. METHODS: Perfluorobutane nanodroplets with a shell made of polyvinyl alcohol (PVA-PFB) or 10,12-pentacosadyinoic acid (PCDA-PFB) were dispersed in polyacrylamide hydrogels and irradiated with 62 MeV passively scattered protons at temperatures of 37°C and 50°C. Nanodroplet transition into echogenic microbubbles was assessed using ultrasound imaging (gray value and attenuation analysis) and optical images. The proton range was measured independently and compared to the generated contrast. RESULTS: Nanodroplet design proved crucial to ensure thermal stability, as PVA-shelled nanodroplets dramatically outperformed their PCDA-shelled counterpart. At body temperature, a uniform radiation response proximal to the Bragg peak is attributed to nuclear reaction products interacting with PVA-PFB nanodroplets, with the 50% drop in ultrasound contrast being 0.17 mm ± 0.20 mm (mean ± standard deviation) in front of the proton range. Also at 50°C, highly reproducible ultrasound contrast profiles were obtained with shifts of -0.74 mm ± 0.09 mm (gray value analysis), -0.86 mm ± 0.04 mm (attenuation analysis) and -0.64 mm ± 0.29 mm (optical analysis). Moreover, a strong contrast enhancement was observed near the Bragg peak, suggesting that nanodroplets were sensitive to primary protons. CONCLUSIONS: By varying the degree of superheat of the nanodroplets' core, one can modulate the intensity of the generated ultrasound contrast. Moreover, a submillimeter reproducible relationship between the ultrasound contrast and the proton range was obtained, either indirectly via the visualization of secondary reaction products or directly through the detection of primary protons, depending on the degree of superheat. The potential of PVA-PFB nanodroplets for in vivo proton range verification was confirmed by observing a reproducible radiation response at physiological temperature, and further studies aim to assess the nanodroplets' performance in a physiological environment. Ultimately, cost-effective online or offline ultrasound imaging of radiation-induced nanodroplet vaporization could facilitate the reduction of safety margins in treatment planning and enable adaptive proton therapy.


Assuntos
Terapia com Prótons , Prótons , Meios de Contraste , Microbolhas , Ultrassonografia
4.
Phys Rev Lett ; 124(8): 081801, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167330

RESUMO

We show that heavy-ion collisions at the LHC provide a promising environment to search for new long-lived particles in well-motivated new physics scenarios. One advantage lies in the possibility to operate the main detectors with looser triggers, which can increase the number of observable events by orders of magnitude if the long-lived particles are produced with low transverse momentum. In addition, the absence of pileup in heavy-ion collisions can avoid systematic nuisances that will be present in future proton runs, such as the problem of vertex misidentification. Finally, there are new production mechanisms that are absent or inefficient in proton collisions. We show that the looser triggers alone can make searches in heavy-ion data competitive with proton data for the specific example of heavy neutrinos in the neutrino minimal standard model, produced in the decay of B mesons. Our results suggest that collisions of ions lighter than lead, which are currently under discussion in the heavy-ion community, are well motivated from the viewpoint of searches for new physics.

5.
Philos Trans A Math Phys Eng Sci ; 377(2137)2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30530546

RESUMO

We report on the first steps in the development of a small-size muon telescope based on glass resistive plate chambers with small active area (16 × 16 cm2). The long-term goal of this project is to focus on applications of muography where the telescope may have to be operated underground and/or inside small rooms, and in challenging logistic situations. Driving principles in our design are therefore compact size, light weight, gas tightness and robustness. The first data-taking experiences have been encouraging, and we elaborate on the lessons learnt and future directions for development.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...