Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Comput Biol Med ; 112: 103361, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31362107

RESUMO

The staging of the central-chest lymph nodes is a major lung-cancer management procedure. To perform a staging procedure, the physician first uses a patient's 3D X-ray computed-tomography (CT) chest scan to interactively plan airway routes leading to selected target lymph nodes. Next, using an integrated EBUS bronchoscope (EBUS = endobronchial ultrasound), the physician uses videobronchoscopy to navigate through the airways toward a target node's general vicinity and then invokes EBUS to localize the node for biopsy. Unfortunately, during the procedure, the physician has difficulty in translating the preplanned airway routes into safe, effective biopsy sites. We propose an automatic route-planning method for EBUS bronchoscopy that gives optimal localization of safe, effective nodal biopsy sites. To run the method, a 3D chest model is first computed from a patient's chest CT scan. Next, an optimization method derives feasible airway routes that enables maximal tissue sampling of target lymph nodes while safely avoiding major blood vessels. In a lung-cancer patient study entailing 31 nodes (long axis range: [9.0 mm, 44.5 mm]), 25/31 nodes yielded safe airway routes having an optimal tissue sample size = 8.4 mm (range: [1.0 mm, 18.6 mm]) and sample adequacy = 0.42 (range: [0.05, 0.93]). Quantitative results indicate that the method potentially enables successful biopsies in essentially 100% of selected lymph nodes versus the 70-94% success rate of other approaches. The method also potentially facilitates adequate tissue biopsies for nearly 100% of selected nodes, as opposed to the 55-77% tissue adequacy rates of standard methods. The remaining nodes did not yield a safe route within the preset safety-margin constraints, with 3 nodes never yielding a route even under the most lenient safety-margin conditions. Thus, the method not only helps determine effective airway routes and expected sample quality for nodal biopsy, but it also helps point out situations where biopsy may not be advisable. We also demonstrate the methodology in an image-guided EBUS bronchoscopy system, used successfully in live lung-cancer patient studies. During a live procedure, the method provides dynamic real-time sample size visualization in an enhanced virtual bronchoscopy viewer. In this way, the physician vividly sees the most promising biopsy sites along the airway walls as the bronchoscope moves through the airways.


Assuntos
Broncoscopia , Tomada de Decisões Assistida por Computador , Neoplasias Pulmonares , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino
2.
J Oral Implantol ; 42(5): 399-405, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27267658

RESUMO

The purpose of this model-based study was to determine the accuracy of placing dental implants using a new dynamic navigation system. This investigation focuses on measurements of overall accuracy for implant placement relative to the virtual plan in both dentate and edentulous models, and provides a comparison with a meta-analysis of values reported in the literature for comparable static guidance, dynamic guidance, and freehand placement studies. This study involves 1 surgeon experienced with dynamic navigation placing implants in models under clinical simulation using a dynamic navigation system (X-Guide, X-Nav Technologies, LLC, Lansdale, Pa) based on optical triangulation tracking. Virtual implants were placed into planned sites using the navigation system computer. Post-implant placement cone-beam scans were taken. These scans were mesh overlaid with the virtual plan and used to determine deviations from the virtual plan. The primary outcome variables were platform and angular deviations comparing the actual placement to the virtual plan. The angular accuracy of implants delivered using the tested device was 0.89° ± 0.35° for dentate case types and 1.26° ± 0.66° for edentulous case types, measured relative to the preoperative implant plan. Three-dimensional positional accuracy was 0.38 ± 0.21 mm for dentate and 0.56 ± 0.17 mm for edentulous, measured from the implant apex.


Assuntos
Desenho Assistido por Computador , Implantação Dentária Endóssea , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional , Boca Edêntula , Planejamento de Assistência ao Paciente , Tomografia Computadorizada por Raios X
3.
IEEE Trans Biomed Eng ; 61(3): 638-57, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24235246

RESUMO

With the development of multidetector computed-tomography (MDCT) scanners and ultrathin bronchoscopes, the use of bronchoscopy for diagnosing peripheral lung-cancer nodules is becoming a viable option. The work flow for assessing lung cancer consists of two phases: 1) 3-D MDCT analysis and 2) live bronchoscopy. Unfortunately, the yield rates for peripheral bronchoscopy have been reported to be as low as 14%, and bronchoscopy performance varies considerably between physicians. Recently, proposed image-guided systems have shown promise for assisting with peripheral bronchoscopy. Yet, MDCT-based route planning to target sites has relied on tedious error-prone techniques. In addition, route planning tends not to incorporate known anatomical, device, and procedural constraints that impact a feasible route. Finally, existing systems do not effectively integrate MDCT-derived route information into the live guidance process. We propose a system that incorporates an automatic optimal route-planning method, which integrates known route constraints. Furthermore, our system offers a natural translation of the MDCT-based route plan into the live guidance strategy via MDCT/video data fusion. An image-based study demonstrates the route-planning method's functionality. Next, we present a prospective lung-cancer patient study in which our system achieved a successful navigation rate of 91% to target sites. Furthermore, when compared to a competing commercial system, our system enabled bronchoscopy over two airways deeper into the airway-tree periphery with a sample time that was nearly 2 min shorter on average. Finally, our system's ability to almost perfectly predict the depth of a bronchoscope's navigable route in advance represents a substantial benefit of optimal route planning.


Assuntos
Broncoscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Radiografia Torácica/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Gravação em Vídeo , Adulto Jovem
4.
J Digit Imaging ; 25(2): 307-17, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22083553

RESUMO

Multi-detector computed tomography (MDCT) scanners produce high-resolution images of the chest. Given a patient's MDCT scan, a physician can use an image-guided intervention system to first plan and later perform bronchoscopy to diagnostic sites situated deep in the lung periphery. An accurate definition of complete routes through the airway tree leading to the diagnostic sites, however, is vital for avoiding navigation errors during image-guided bronchoscopy. We present a system for the robust definition of complete airway routes suitable for image-guided bronchoscopy. The system incorporates both automatic and semiautomatic MDCT analysis methods for this purpose. Using an intuitive graphical user interface, the user invokes automatic analysis on a patient's MDCT scan to produce a series of preliminary routes. Next, the user visually inspects each route and quickly corrects the observed route defects using the built-in semiautomatic methods. Application of the system to a human study for the planning and guidance of peripheral bronchoscopy demonstrates the efficacy of the system.


Assuntos
Broncografia/métodos , Broncoscopia/métodos , Imageamento Tridimensional/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador , Algoritmos , Humanos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
5.
IEEE Trans Med Imaging ; 29(4): 982-97, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20335095

RESUMO

A vital task in the planning of peripheral bronchoscopy is the segmentation of the airway tree from a 3-D multidetector computed tomography chest scan. Unfortunately, existing methods typically do not sufficiently extract the necessary peripheral airways needed to plan a procedure. We present a robust method that draws upon both local and global information. The method begins with a conservative segmentation of the major airways. Follow-on stages then exhaustively search for additional candidate airway locations. Finally, a graph-based optimization method counterbalances both the benefit and cost of retaining candidate airway locations for the final segmentation. Results demonstrate that the proposed method typically extracts 2-3 more generations of airways than several other methods, and that the extracted airway trees enable image-guided bronchoscopy deeper into the human lung periphery than past studies.


Assuntos
Brônquios/anatomia & histologia , Brônquios/cirurgia , Broncoscopia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Cirurgia Assistida por Computador/métodos , Algoritmos , Inteligência Artificial , Humanos , Aumento da Imagem/métodos , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Digit Imaging ; 23(1): 39-50, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19050956

RESUMO

Bronchoscopy is often performed for staging lung cancer. The recent development of multidetector computed tomography (MDCT) scanners and ultrathin bronchoscopes now enable the bronchoscopic biopsy and treatment of peripheral diagnostic regions of interest (ROIs). Because these ROIs are often located several generations within the airway tree, careful planning and interpretation of the bronchoscopic route is required prior to a procedure. The current practice for planning bronchoscopic procedures, however, is difficult, error prone, and time consuming. To alleviate these issues, we propose a method for producing and previewing reports for bronchoscopic procedures using patient-specific MDCT chest scans. The reports provide quantitative data about the bronchoscopic routes and both static and dynamic previews of the proper airway route. The previews consist of virtual bronchoscopic endoluminal renderings along the route and three-dimensional cues for a final biopsy site. The reports require little storage space and computational resources, enabling physicians to view the reports on a portable tablet PC. To evaluate the efficacy of the reporting system, we have generated reports for 22 patients in a human lung cancer patient pilot study. For 17 of these patients, we used the reports in conjunction with live image-based bronchoscopic guidance to direct physicians to central chest and peripheral ROIs for subsequent diagnostic evaluation. Our experience shows that the tool enabled useful procedure preview and an effective means for planning strategy prior to a live bronchoscopy.


Assuntos
Broncoscopia , Diagnóstico por Computador/instrumentação , Neoplasias Pulmonares/patologia , Radiografia Intervencionista , Tomografia Computadorizada por Raios X/métodos , Biópsia , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/diagnóstico por imagem , Estadiamento de Neoplasias , Interface Usuário-Computador
7.
Comput Biol Med ; 39(3): 266-79, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19217089

RESUMO

The diagnosis and staging of lung cancer often begins with the assessment of a suspect peripheral chest site. Such suspicious peripheral sites may be solitary pulmonary nodules or other abnormally appearing regions of interest (ROIs). The state-of-the-art process for assessing such peripheral ROIs involves off-line procedure planning using a three-dimensional (3D) multidetector computed tomography (MDCT) chest scan followed by bronchoscopy with an ultrathin bronchoscope. We present an integrated computer-based system for planning peripheral bronchoscopic procedures. The system takes a 3D MDCT chest image as input and performs nearly all operations automatically. The only interaction required by the physician is the selection of ROI locations. The system is computationally efficient and fits smoothly within the clinical work flow. Integrated into the system and described in detail in the paper is a new surface-definition method, which is vital for effective analysis and planning to peripheral sites. Results demonstrate the efficacy of the system and its usage for the live guidance of ultrathin bronchoscopy to the periphery.


Assuntos
Broncoscopia/métodos , Diagnóstico por Computador/instrumentação , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X/métodos , Automação , Computadores , Humanos , Modelos Anatômicos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Software , Propriedades de Superfície
8.
Chest ; 134(5): 1017-1026, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18583513

RESUMO

BACKGROUND: Ultrathin bronchoscopy guided by virtual bronchoscopy (VB) techniques show promise for the diagnosis of peripheral lung lesions. In a phantom study, we evaluated a new real-time, VB-based, image-guided system for guiding the bronchoscopic biopsy of peripheral lung lesions and compared its performance to that of standard bronchoscopy practice. METHODS: Twelve bronchoscopists of varying experience levels participated in the study. The task was to use an ultrathin bronchoscope and a biopsy forceps to localize 10 synthetically created lesions situated at varying airway depths. For route planning and guidance, the bronchoscopists employed either standard bronchoscopy practice or the real-time image-guided system. Outcome measures were biopsy site position error, which was defined as the distance from the forceps contact point to the ground-truth lesion boundary, and localization success, which was defined as a site identification having a biopsy site position error of < or = 5 mm. RESULTS: Mean (+/- SD) localization success more than doubled from 43 +/- 16% using standard practice to 94 +/- 7.9% using image guidance (p < 10(-15) [McNemar paired test]). The mean biopsy site position error dropped from 9.7 +/- 9.1 mm for standard practice to 2.2 +/- 2.3 mm for image guidance. For standard practice, localization success decreased from 56% for generation 3 to 4 lesions to 31% for generation 6 to 8 lesions and also decreased from 51% for lesions on a carina vs 23% for lesions situated away from a carina. These factors were far less pronounced when using image guidance, as follows: success for generation 3 to 4 lesions, 97%; success for generation 6 to 8 lesions, 91%; success for lesions on a carina, 98%; success for lesions away from a carina, 86%. Bronchoscopist experience did not significantly affect performance using the image-guided system. CONCLUSIONS: Real-time, VB-based image guidance can potentially far exceed standard bronchoscopy practice for enabling the bronchoscopic biopsy of peripheral lung lesions.


Assuntos
Broncoscopia/métodos , Pneumopatias/diagnóstico , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Biópsia/métodos , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...