Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 15(4): 2110-2113, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633102

RESUMO

A feature issue is being presented by a team of guest editors containing papers based on contributed submissions including studies presented at Optics and the Brain, held April 24-27, 2023 as part of Optica Biophotonics Congress: Optics in the Life Sciences, in Vancouver, Canada.

2.
Nat Neurosci ; 27(5): 846-861, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38539013

RESUMO

The generation of new myelin-forming oligodendrocytes in the adult central nervous system is critical for cognitive function and regeneration following injury. Oligodendrogenesis varies between gray and white matter regions, suggesting that local cues drive regional differences in myelination and the capacity for regeneration. However, the layer- and region-specific regulation of oligodendrocyte populations is unclear due to the inability to monitor deep brain structures in vivo. Here we harnessed the superior imaging depth of three-photon microscopy to permit long-term, longitudinal in vivo three-photon imaging of the entire cortical column and subcortical white matter in adult mice. We find that cortical oligodendrocyte populations expand at a higher rate in the adult brain than those of the white matter. Following demyelination, oligodendrocyte replacement is enhanced in the white matter, while the deep cortical layers show deficits in regenerative oligodendrogenesis and the restoration of transcriptional heterogeneity. Together, our findings demonstrate that regional microenvironments regulate oligodendrocyte population dynamics and heterogeneity in the healthy and diseased brain.


Assuntos
Oligodendroglia , Substância Branca , Animais , Oligodendroglia/fisiologia , Camundongos , Substância Branca/fisiologia , Doenças Desmielinizantes/patologia , Bainha de Mielina/fisiologia , Camundongos Endogâmicos C57BL , Masculino , Camundongos Transgênicos , Regeneração Nervosa/fisiologia , Feminino , Encéfalo/fisiologia , Encéfalo/citologia , Neurogênese/fisiologia
3.
Curr Biol ; 34(4): 841-854.e4, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38325376

RESUMO

Sequential neural dynamics encoded by time cells play a crucial role in hippocampal function. However, the role of hippocampal sequential neural dynamics in associative learning is an open question. We used two-photon Ca2+ imaging of dorsal CA1 (dCA1) neurons in the stratum pyramidale (SP) in head-fixed mice performing a go-no go associative learning task to investigate how odor valence is temporally encoded in this area of the brain. We found that SP cells responded differentially to the rewarded or unrewarded odor. The stimuli were decoded accurately from the activity of the neuronal ensemble, and accuracy increased substantially as the animal learned to differentiate the stimuli. Decoding the stimulus from individual SP cells responding differentially revealed that decision-making took place at discrete times after stimulus presentation. Lick prediction decoded from the ensemble activity of cells in dCA1 correlated linearly with lick behavior. Our findings indicate that sequential activity of SP cells in dCA1 constitutes a temporal memory map used for decision-making in associative learning. VIDEO ABSTRACT.


Assuntos
Região CA1 Hipocampal , Hipocampo , Camundongos , Animais , Região CA1 Hipocampal/fisiologia , Neurônios/fisiologia , Aprendizagem , Condicionamento Clássico
4.
bioRxiv ; 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37961298

RESUMO

The generation of new myelin-forming oligodendrocytes in the adult CNS is critical for cognitive function and regeneration following injury. Oligodendrogenesis varies between gray and white matter regions suggesting that local cues drive regional differences in myelination and the capacity for regeneration. Yet, the determination of regional variability in oligodendrocyte cell behavior is limited by the inability to monitor the dynamics of oligodendrocytes and their transcriptional subpopulations in white matter of the living brain. Here, we harnessed the superior imaging depth of three-photon microscopy to permit long-term, longitudinal in vivo three-photon imaging of an entire cortical column and underlying subcortical white matter without cellular damage or reactivity. Using this approach, we found that the white matter generated substantially more new oligodendrocytes per volume compared to the gray matter, yet the rate of population growth was proportionally higher in the gray matter. Following demyelination, the white matter had an enhanced population growth that resulted in higher oligodendrocyte replacement compared to the gray matter. Finally, deep cortical layers had pronounced deficits in regenerative oligodendrogenesis and restoration of the MOL5/6-positive oligodendrocyte subpopulation following demyelinating injury. Together, our findings demonstrate that regional microenvironments regulate oligodendrocyte population dynamics and heterogeneity in the healthy and diseased brain.

5.
Biomed Opt Express ; 14(7): 3705-3725, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37497482

RESUMO

We demonstrate a gradient refractive index (GRIN) microendoscope with an outer diameter of ∼1.2 mm and a length of ∼186 mm that can fit into a stereotactic surgical cannula. Two photon imaging at an excitation wavelength of 900 nm showed a field of view of ∼180 microns and a lateral and axial resolution of 0.86 microns and 9.6 microns respectively. The microendoscope was tested by imaging autofluorescence and second harmonic generation (SHG) in label-free human brain tissue. Furthermore, preliminary image analysis indicates that image classification models can predict if an image is from the subthalamic nucleus or the surrounding tissue using conventional, bench-top two-photon autofluorescence.

6.
Opt Express ; 31(10): 16709-16718, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37157744

RESUMO

Optical sectioning structured illumination microscopy (OS-SIM) provides optical sectioning capability in wide-field microscopy. The required illumination patterns have traditionally been generated using spatial light modulators (SLM), laser interference patterns, or digital micromirror devices (DMDs) which are too complex to implement in miniscope systems. MicroLEDs have emerged as an alternative light source for patterned illumination due to their extreme brightness capability and small emitter sizes. This paper presents a directly addressable striped microLED microdisplay with 100 rows on a flexible cable (70 cm long) for use as an OS-SIM light source in a benchtop setup. The overall design of the microdisplay is described in detail with luminance-current-voltage characterization. OS-SIM implementation with a benchtop setup shows the optical sectioning capability of the system by imaging within a 500 µm thick fixed brain slice from a transgenic mouse where oligodendrocytes are labeled with a green fluorescent protein (GFP). Results show improved contrast in reconstructed optically sectioned images of 86.92% (OS-SIM) compared with 44.31% (pseudo-widefield). MicroLED based OS-SIM therefore offers a new capability for deep tissue widefield imaging.

7.
Neurophotonics ; 9(4): 045009, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36466189

RESUMO

Significance: In vivo imaging and electrophysiology are powerful tools to explore neuronal function that each offer unique complementary information with advantages and limitations. Capturing both data types from the same neural population in the freely moving animal would allow researchers to take advantage of the capabilities of both modalities and further understand how they relate to each other. Aim: Here, we present a head-mounted neural implant suitable for in vivo two-photon imaging of neuronal activity with simultaneous extracellular electrical recording in head-fixed or fiber-coupled freely moving animals. Approach: A gradient refractive index (GRIN) lens-based head-mounted neural implant with extracellular electrical recording provided by tetrodes on the periphery of the GRIN lens was chronically implanted. The design of the neural implant allows for recording from head-fixed animals, as well as freely moving animals by coupling the imaging system to a coherent imaging fiber bundle. Results: We demonstrate simultaneous two-photon imaging of GCaMP and extracellular electrophysiology of neural activity in awake head-fixed and freely moving mice. Using the collected information, we perform correlation analysis to reveal positive correlation between optical and local field potential recordings. Conclusion: Simultaneously recording neural activity using both optical and electrical methods provides complementary information from each modality. Designs that can provide such bi-modal recording in freely moving animals allow for the investigation of neural activity underlying a broader range of behavioral paradigms.

8.
Neurophotonics ; 9(3): 031912, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35496497

RESUMO

Significance: Three-photon (3P) microscopy significantly increases the depth and resolution of in vivo imaging due to decreased scattering and nonlinear optical sectioning. Simultaneous excitation of multiple fluorescent proteins is essential to studying multicellular interactions and dynamics in the intact brain. Aim: We characterized the excitation laser pulses at a range of wavelengths for 3P microscopy, and then explored the application of tdTomato or mScarlet and EGFP for dual-color single-excitation structural 3P imaging deep in the living mouse brain. Approach: We used frequency-resolved optical gating to measure the spectral intensity, phase, and retrieved pulse widths at a range of wavelengths. Then, we performed in vivo single wavelength-excitation 3P imaging in the 1225- to 1360-nm range deep in the mouse cerebral cortex to evaluate the performance of tdTomato or mScarlet in combination with EGFP. Results: We find that tdTomato and mScarlet, expressed in oligodendrocytes and neurons respectively, have a high signal-to-background ratio in the 1300- to 1360-nm range, consistent with enhanced 3P cross-sections. Conclusions: These results suggest that a single excitation wavelength source is advantageous for multiple applications of dual-color brain imaging and highlight the importance of empirical characterization of individual fluorophores for 3P microscopy.

9.
Biomed Opt Express ; 13(4): 2530-2541, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519247

RESUMO

We present a high-resolution miniature, light-weight fluorescence microscope with electrowetting lens and onboard CMOS for high resolution volumetric imaging and structured illumination for rejection of out-of-focus and scattered light. The miniature microscope (SIMscope3D) delivers structured light using a coherent fiber bundle to obtain optical sectioning with an axial resolution of 18 µm. Volumetric imaging of eGFP labeled cells in fixed mouse brain tissue at depths up to 260 µm is demonstrated. The functionality of SIMscope3D to provide background free 3D imaging is shown by recording time series of microglia dynamics in awake mice at depths up to 120 µm in the brain.

10.
Methods Mol Biol ; 2413: 193-209, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35044667

RESUMO

Raman spectroscopy using feature selection schemes has considerable advantages over gas chromatography for the analysis of fatty acids' composition changes. Here, we introduce an educational methodology to demonstrate the potential of micro-Raman spectroscopy to determine with high accuracy the unsaturation or saturation degrees and composition changes of the fatty acids found in the lipid droplets of the LNCaP prostate cancer cells that were treated with various fatty acids. The methodology uses highly discriminatory wavenumbers among fatty acids present in the sample selected by using the Support Vector Machine algorithm.


Assuntos
Gotículas Lipídicas , Neoplasias , Ácidos Graxos/química , Humanos , Gotículas Lipídicas/química , Masculino , Microscopia/métodos , Análise Espectral Raman/métodos , Máquina de Vetores de Suporte
11.
Biomed Opt Express ; 12(10): 6269-6276, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745735

RESUMO

We demonstrate a near-infrared, femtosecond, diode laser-based source with kW peak power for two-photon microscopy. At a wavelength of 976 nm, the system produces sub-ps pulses operating at a repetition rate of 10 MHz with kilowatt class peak powers suitable for deep tissue two-photon microscopy. The system, integrated with a laser-scanning microscope, images to a depth of 900 µm in a fixed sample of PLP-eGFP labeled mouse brain tissue. This represents a significant development that will lead to more efficient, compact, and accessible laser sources for biomedical imaging.

12.
Sci Rep ; 11(1): 3664, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33574459

RESUMO

Vagus nerve stimulation has shown many benefits for disease therapies but current approaches involve imprecise electrical stimulation that gives rise to off-target effects, while the functionally relevant pathways remain poorly understood. One method to overcome these limitations is the use of optogenetic techniques, which facilitate targeted neural communication with light-sensitive actuators (opsins) and can be targeted to organs of interest based on the location of viral delivery. Here, we tested whether retrograde adeno-associated virus (rAAV2-retro) injected in the heart can be used to selectively express opsins in vagus nerve fibers controlling cardiac function. Furthermore, we investigated whether perturbations in cardiac function could be achieved with photostimulation at the cervical vagus nerve. Viral injection in the heart resulted in robust, primarily afferent, opsin reporter expression in the vagus nerve, nodose ganglion, and brainstem. Photostimulation using both one-photon stimulation and two-photon holography with a GRIN-lens incorporated nerve cuff, was tested on the pilot-cohort of injected mice. Changes in heart rate, surface electrocardiogram, and respiratory responses were observed in response to both one- and two-photon photostimulation. The results demonstrate feasibility of retrograde labeling for organ targeted optical neuromodulation.


Assuntos
Dependovirus/genética , Coração/virologia , Opsinas/genética , Nervo Vago/metabolismo , Animais , Estimulação Elétrica , Coração/fisiopatologia , Frequência Cardíaca/genética , Frequência Cardíaca/fisiologia , Humanos , Camundongos , Neurônios/metabolismo , Neurônios/virologia , Optogenética/métodos , Respiração/genética , Nervo Vago/fisiologia , Nervo Vago/virologia , Estimulação do Nervo Vago/métodos
13.
J Raman Spectrosc ; 52(11): 1910-1922, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35814195

RESUMO

Lipid droplets are dynamic organelles that play important cellular roles. They are composed of a phospholipid membrane and a core of triglycerides and sterol esters. Fatty acids have important roles in phospholipid membrane formation, signaling, and synthesis of triglycerides as energy storage. Better non-invasive tools for profiling and measuring cellular lipids are needed. Here we demonstrate the potential of Raman spectroscopy to determine with high accuracy the composition changes of the fatty acids and cholesterol found in the lipid droplets of prostate cancer cells treated with various fatty acids. The methodology uses a modified least squares fitting (LSF) routine that uses highly discriminatory wavenumbers between the fatty acids present in the sample using a support vector machine algorithm. Using this new LSF routine, Raman micro-spectroscopy can become a better non-invasive tool for profiling and measuring fatty acids and cholesterol for cancer biology.

14.
Nat Commun ; 11(1): 4217, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32868778

RESUMO

The cerebellum plays a crucial role in sensorimotor and associative learning. However, the contribution of molecular layer interneurons (MLIs) to these processes is not well understood. We used two-photon microscopy to study the role of ensembles of cerebellar MLIs in a go-no go task where mice obtain a sugar water reward if they lick a spout in the presence of the rewarded odorant and avoid a timeout when they refrain from licking for the unrewarded odorant. In naive animals the MLI responses did not differ between the odorants. With learning, the rewarded odorant elicited a large increase in MLI calcium responses, and the identity of the odorant could be decoded from the differential response. Importantly, MLIs switched odorant responses when the valence of the stimuli was reversed. Finally, mice took a longer time to refrain from licking in the presence of the unrewarded odorant and had difficulty becoming proficient when MLIs were inhibited by chemogenetic intervention. Our findings support a role for MLIs in learning valence in the cerebellum.


Assuntos
Cerebelo/fisiologia , Condicionamento Operante/fisiologia , Interneurônios/fisiologia , Aprendizagem/fisiologia , Células de Purkinje/fisiologia , Algoritmos , Animais , Cerebelo/citologia , Feminino , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Microscopia de Fluorescência por Excitação Multifotônica , Modelos Neurológicos , Odorantes , Recompensa , Fatores de Tempo
15.
Sci Rep ; 9(1): 11137, 2019 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-31366899

RESUMO

We present results for a new type of fiber-coupled stimulated emission depletion (STED) microscope which uses a single fiber to transport STED and excitation light, as well as collect the fluorescence signal. Our method utilizes two higher-order eigenmodes of polarization maintaining (PM) fiber to generate the doughnut-shaped STED beam. The modes are excited with separate beams that share no temporal coherence, yielding output that is independent of fiber bending. We measured the resolution using 45 nm fluorescent beads and found a median bead image size of 116 nm. This resolution does not change as function of fiber bending radius, demonstrating robust operation. We report, for the first time, STED images of fixed biological samples collected in the epi-direction through fiber. Our microscope design shows promise for future use in super-resolution micro-endoscopes and in vivo neural imaging in awake and freely-behaving animals.

16.
Sci Rep ; 8(1): 8108, 2018 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-29802371

RESUMO

We present a miniature head mounted two-photon fiber-coupled microscope (2P-FCM) for neuronal imaging with active axial focusing enabled using a miniature electrowetting lens. We show three-dimensional two-photon imaging of neuronal structure and record neuronal activity from GCaMP6s fluorescence from multiple focal planes in a freely-moving mouse. Two-color simultaneous imaging of GFP and tdTomato fluorescence is also demonstrated. Additionally, dynamic control of the axial scanning of the electrowetting lens allows tilting of the focal plane enabling neurons in multiple depths to be imaged in a single plane. Two-photon imaging allows increased penetration depth in tissue yielding a working distance of 450 µm with an additional 180 µm of active axial focusing. The objective NA is 0.45 with a lateral resolution of 1.8 µm, an axial resolution of 10 µm, and a field-of-view of 240 µm diameter. The 2P-FCM has a weight of only ~2.5 g and is capable of repeatable and stable head-attachment. The 2P-FCM with dynamic axial scanning provides a new capability to record from functionally distinct neuronal layers, opening new opportunities in neuroscience research.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/instrumentação , Microscopia de Fluorescência por Excitação Multifotônica/instrumentação , Movimento , Animais , Cor , Camundongos
17.
Opt Express ; 25(25): 31451-31461, 2017 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-29245820

RESUMO

We present numerical simulations of multielectrode electrowetting devices used in a novel optical design to correct wavefront aberration. Our optical system consists of two multielectrode devices, preceded by a single fixed lens. The multielectrode elements function as adaptive optical devices that can be used to correct aberrations inherent in many imaging setups, biological samples, and the atmosphere. We are able to accurately simulate the liquid-liquid interface shape using computational fluid dynamics. Ray tracing analysis of these surfaces shows clear evidence of aberration correction. To demonstrate the strength of our design, we studied three different input aberrations mixtures that include astigmatism, coma, trefoil, and additional higher order aberration terms, with amplitudes as large as one wave at 633 nm.

18.
Sci Rep ; 7(1): 4744, 2017 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-28720792

RESUMO

Current neural interface technologies have serious limitations for advanced prosthetic and therapeutic applications due primarily to their lack of specificity in neural communication. An optogenetic approach has the potential to provide single cell/axon resolution in a minimally invasive manner by optical interrogation of light-sensitive reporters and actuators. Given the aim of reading neural activity in the peripheral nervous system, this work has investigated an activity-dependent signaling mechanism in the peripheral nerve. We demonstrate action potential evoked calcium signals in mammalian tibial nerve axons using an in vitro mouse model with a dextran-conjugated fluorescent calcium indicator. Spatial and temporal dynamics of the signal are presented, including characterization of frequency-modulated amplitude. Pharmacological experiments implicate T-type CaV channels and sodium-calcium exchanger (NCX) as predominant mechanisms of calcium influx. This work shows the potential of using calcium-associated optical signals for neural activity read-out in peripheral nerve axons.


Assuntos
Axônios/fisiologia , Sinalização do Cálcio , Nervos Periféricos/fisiologia , Nós Neurofibrosos/fisiologia , Tíbia/metabolismo , Potenciais de Ação , Animais , Canais de Cálcio Tipo T/metabolismo , Potenciais Evocados , Camundongos , Optogenética , Trocador de Sódio e Cálcio/metabolismo , Tíbia/inervação
19.
Cytometry A ; 91(7): 662-674, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28608985

RESUMO

Detection of circulating tumor cells (CTCs) in a blood sample is limited by the sensitivity and specificity of the biomarker panel used to identify CTCs over other blood cells. In this work, we present Bayesian theory that shows how test sensitivity and specificity set the rarity of cell that a test can detect. We perform our calculation of sensitivity and specificity on our image cytometry biomarker panel by testing on pure disease positive (D+ ) populations (MCF7 cells) and pure disease negative populations (D- ) (leukocytes). In this system, we performed multi-channel confocal fluorescence microscopy to image biomarkers of DNA, lipids, CD45, and Cytokeratin. Using custom software, we segmented our confocal images into regions of interest consisting of individual cells and computed the image metrics of total signal, second spatial moment, spatial frequency second moment, and the product of the spatial-spatial frequency moments. We present our analysis of these 16 features. The best performing of the 16 features produced an average separation of three standard deviations between D+ and D- and an average detectable rarity of ∼1 in 200. We performed multivariable regression and feature selection to combine multiple features for increased performance and showed an average separation of seven standard deviations between the D+ and D- populations making our average detectable rarity of ∼1 in 480. Histograms and receiver operating characteristics (ROC) curves for these features and regressions are presented. We conclude that simple regression analysis holds promise to further improve the separation of rare cells in cytometry applications. © 2017 International Society for Advancement of Cytometry.


Assuntos
DNA/análise , Queratinas/metabolismo , Antígenos Comuns de Leucócito/metabolismo , Metabolismo dos Lipídeos , Células Neoplásicas Circulantes/patologia , Antígenos de Neoplasias/metabolismo , Biomarcadores Tumorais/análise , Linhagem Celular Tumoral , Separação Celular/métodos , Humanos , Citometria por Imagem/métodos , Lipídeos
20.
Biophys J ; 112(8): 1692-1702, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-28445760

RESUMO

Determining the spatial relationship of individual proteins in dense assemblies remains a challenge for superresolution nanoscopy. The organization of aquaporin-4 (AQP4) into large plasma membrane assemblies provides an opportunity to image membrane-bound AQP4 antibodies (AQP4-IgG) and evaluate changes in their spatial distribution due to alterations in AQP4 isoform expression and AQP4-IgG epitope specificity. Using stimulated emission depletion nanoscopy, we imaged secondary antibody labeling of monoclonal AQP4-IgGs with differing epitope specificity bound to isolated tetramers (M1-AQP4) and large orthogonal arrays of AQP4 (M23-AQP4). Imaging secondary antibodies bound to M1-AQP4 allowed us to infer the size of individual AQP4-IgG binding events. This information was used to model the assembly of larger AQP4-IgG complexes on M23-AQP4 arrays. A scoring algorithm was generated from these models to characterize the spatial arrangement of bound AQP4-IgG antibodies, yielding multiple epitope-specific patterns of bound antibodies on M23-AQP4 arrays. Our results delineate an approach to infer spatial relationships within protein arrays using stimulated emission depletion nanoscopy, offering insight into how information on single antibody fluorescence events can be used to extract information from dense protein assemblies under a biologic context.


Assuntos
Aquaporina 4/imunologia , Autoanticorpos/metabolismo , Membrana Celular/metabolismo , Algoritmos , Animais , Aquaporina 4/química , Aquaporina 4/ultraestrutura , Autoanticorpos/química , Autoanticorpos/ultraestrutura , Células CHO , Simulação por Computador , Cricetulus , Epitopos , Imunoglobulina G/química , Imunoglobulina G/metabolismo , Imunoglobulina G/ultraestrutura , Análise dos Mínimos Quadrados , Microscopia Confocal , Microscopia de Fluorescência/métodos , Modelos Moleculares , Neuromielite Óptica/imunologia , Isoformas de Proteínas , Análise Espacial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...