1.
Invest Ophthalmol Vis Sci ; 40(5): 826-30, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10102278

RESUMO

PURPOSE: To determine the human corneal threshold ablation energy density for the 193-nm ArF excimer laser, approximating clinical conditions. METHODS: The VISX Star (Santa Clara, CA) 193-nm argon fluoride excimer laser was used to ablate the cornea in human eye bank eyes under clinical conditions. Corneas were exposed to energy densities of 10, 20, 30, 35, 40, 45, and 140 to 160 mJ/cm2. Corneas were fixed for light and transmission electron microscopy immediately after laser exposure. RESULTS: Different ablation thresholds for various corneal structural elements were observed. The ablation threshold for the collagen in the corneal stroma was determined to be 30 mJ/cm2. Keratocytes had ablation thresholds of 40 mJ/cm2. These different ablation thresholds accounted for the production of stromal peaks and valleys, with the keratocytes atop the peaks. CONCLUSIONS: Different corneal structural elements have different ablation threshold energy densities.


Assuntos
Córnea/patologia , Córnea/cirurgia , Ceratectomia Fotorrefrativa , Colágeno/metabolismo , Córnea/metabolismo , Substância Própria/metabolismo , Substância Própria/patologia , Fibroblastos/patologia , Humanos , Lasers de Excimer
2.
J Cataract Refract Surg ; 24(6): 765-71, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9642585

RESUMO

PURPOSE: To investigate the astigmatic keratotomy effect of a modified single-hinge cataract incision. SETTING: Department of Ophthalmology, San Juan de Dios Hospital, Tenerife, Spain. METHODS: This prospective study evaluated the astigmatic changes resulting from preincision grooves of less than 40, 45, and 55 degrees in arc length used with a single-hinge, self-sealing cataract incision in 144 eyes that had against-the-rule corneal astigmatism preoperatively. The intended 90% depth preincision was centered on the steep meridian and lengthened according to the amount of preoperative astigmatism. Outcome measurements were obtained by calculating the surgically induced astigmatism vectors and the postoperative keratometry changes 1 day, 1 week, and 1, 3, and 6 months after surgery. RESULTS: Three months postoperatively, astigmatism decreased by 0.03, 0.30, and 0.68 diopter in the less than 40, 45, and 55 degree incision length groups, respectively. The differences between the 45 and 55 degree groups and the less than 40 degree group was statistically significant (P < .05). Similar results were observed 6 months after surgery. CONCLUSION: The astigmatic preincision modification produced statistically significant increasing reductions in preoperative astigmatism according to preincision length.