Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(13): 21107-21117, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37381218

RESUMO

Recently, fluorescence-based optical techniques have emerged as a powerful tool to probe information in the mammalian brain. However, tissue heterogeneities prevent clear imaging of deep neuron bodies due to light scattering. While several up-to-date approaches based on ballistic light allow to retrieve information at shallow depths inside the brain, non-invasive localization and functional imaging at depth still remains a challenge. It was recently shown that functional signals from time-varying fluorescent emitters located behind scattering samples could be retrieved by using a matrix factorization algorithm. Here we show that the seemingly information-less, low-contrast fluorescent speckle patterns recovered by the algorithm can be used to locate each individual emitter, even in the presence of background fluorescence. We test our approach by imaging the temporal activity of large groups of fluorescent sources behind different scattering phantoms mimicking biological tissues, and through a brain slice with a thickness of ∼200 µm.


Assuntos
Algoritmos , Diagnóstico por Imagem , Animais , Fluorescência , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem , Corantes , Mamíferos
2.
ArXiv ; 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36824429

RESUMO

Recently, fluorescence-based optical techniques have emerged as a powerful tool to probe information in the mammalian brain. However, tissue heterogeneities prevent clear imaging of deep neuron bodies due to light scattering. While several up-to-date approaches based on ballistic light allow to retrieve information at shallow depths inside the brain, non-invasive localization and functional imaging at depth still remains a challenge. It was recently shown that functional signals from time-varying fluorescent emitters located behind scattering samples could be retrieved by using a matrix factorization algorithm. Here we show that the seemingly information-less, low-contrast fluorescent speckle patterns recovered by the algorithm can be used to locate each individual emitter, even in the presence of background fluorescence. We test our approach by imaging the temporal activity of large groups of fluorescent sources behind different scattering phantoms mimicking biological tissues, and through a brain slice with a thickness of ~200 micron.

3.
Opt Express ; 30(17): 30058-30065, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-36242117

RESUMO

Reconfigurable linear optical networks are a key component for the development of optical quantum information processing platforms in the NISQ era and beyond. We report the implementation of such a device based on an innovative design that uses the mode mixing of a multimode fiber in combination with the programmable wavefront shaping of a SLM. The capabilities of the platform are explored in the classical regime. For up to 8 inputs and a record number of 38 outputs, we achieve fidelities in excess of 93%, and losses below 6.5dB. The device was built inside a standard server rack to allow for real world use and shows consistent performance for 2x8 circuits over a period of 10 days without re-calibration.

4.
Opt Lett ; 42(23): 4994-4997, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29216164

RESUMO

We describe a fast continuous optimization wavefront shaping system able to focus light through dynamic scattering media. A micro-electro-mechanical system-based spatial light modulator, a fast photodetector, and field programmable gate array electronics are combined to implement a continuous optimization of a wavefront with a single-mode optimization rate of 4.1 kHz. The system performances are demonstrated by focusing light through colloidal solutions of TiO2 particles in glycerol with tunable temporal stability.

5.
Opt Lett ; 39(21): 6090-3, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25361286

RESUMO

We investigate the possibility of using a scattering medium as a highly multimode platform for implementing quantum walks. We demonstrate the manipulation of a single photon propagating through a strongly scattering medium using wavefront-shaping technique. Measurement of the scattering matrix allows the wavefront of the photon to be shaped to compensate the distortions induced by multiple scattering events. The photon can thus be directed coherently to a specific output mode. Using this approach, we show how entanglement of a single photon across different modes can be manipulated despite the enormous wavefront disturbance caused by the scattering medium.

6.
Phys Rev Lett ; 109(3): 033903, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861853

RESUMO

Active control of the spatial pump profile is proposed to exercise control over random laser emission. We demonstrate numerically the selection of any desired lasing mode from the emission spectrum. An iterative optimization method is employed, first in the regime of strong scattering where modes are spatially localized and can be easily selected using local pumping. Remarkably, this method works efficiently even in the weakly scattering regime, where strong spatial overlap of the modes precludes spatial selectivity. A complex optimized pump profile is found, which selects the desired lasing mode at the expense of others, thus demonstrating the potential of pump shaping for robust and controllable single mode operation of a random laser.

7.
Phys Rev Lett ; 107(26): 263901, 2011 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-22243156

RESUMO

We report on the experimental measurement of the backscattering matrix of a weakly scattering medium in optics, composed of a few dispersed gold nanobeads. The decomposition of the time-reversal operator is applied to this matrix and we demonstrate selective and efficient focusing on individual scatterers, even through an aberrating layer. Moreover, we show that this approach provides the decomposition of the scattering pattern of a single nanoparticle. These results open important perspectives for optical imaging, characterization, and selective excitation of nanoparticles.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Fenômenos Ópticos , Lasers , Microesferas , Fatores de Tempo
8.
Phys Rev Lett ; 104(10): 100601, 2010 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-20366410

RESUMO

We introduce a method to experimentally measure the monochromatic transmission matrix of a complex medium in optics. This method is based on a spatial phase modulator together with a full-field interferometric measurement on a camera. We determine the transmission matrix of a thick random scattering sample. We show that this matrix exhibits statistical properties in good agreement with random matrix theory and allows light focusing and imaging through the random medium. This method might give important insight into the mesoscopic properties of a complex medium.

9.
Opt Lett ; 34(10): 1576-8, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19448826

RESUMO

We report experimental evidence and correction of defocus in full-field optical coherence tomography of biological samples owing to mismatch of the refractive index of biological tissues and water. Via a metric based on the image quality, we demonstrate that we are able to compensate this index-induced defocus and to recover a sharp image in depth.


Assuntos
Tomografia de Coerência Óptica/métodos , Análise de Fourier , Aumento da Imagem , Linfonodos , Água
10.
Phys Rev Lett ; 98(3): 030405, 2007 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-17358666

RESUMO

We show how stationary entanglement between an optical cavity field mode and a macroscopic vibrating mirror can be generated by means of radiation pressure. We also show how the generated optomechanical entanglement can be quantified, and we suggest an experimental readout scheme to fully characterize the entangled state. Surprisingly, such optomechanical entanglement is shown to persist for environment temperatures above 20 K using state-of-the-art experimental parameters.

11.
Phys Rev Lett ; 99(25): 250401, 2007 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-18233499

RESUMO

We propose an immediately realizable scheme showing signatures of multipartite entanglement generated by radiation pressure in a cavity system with a movable mirror. We show how the entanglement involving the inaccessible massive object is unraveled by means of field-field quantum correlations and persists within a wide range of working conditions. Our proposal provides an operative way to infer the quantum behavior of a system that is only partially accessible.

12.
Nature ; 444(7115): 67-70, 2006 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-17080084

RESUMO

Cooling of mechanical resonators is currently a popular topic in many fields of physics including ultra-high precision measurements, detection of gravitational waves and the study of the transition between classical and quantum behaviour of a mechanical system. Here we report the observation of self-cooling of a micromirror by radiation pressure inside a high-finesse optical cavity. In essence, changes in intensity in a detuned cavity, as caused by the thermal vibration of the mirror, provide the mechanism for entropy flow from the mirror's oscillatory motion to the low-entropy cavity field. The crucial coupling between radiation and mechanical motion was made possible by producing free-standing micromirrors of low mass (m approximately 400 ng), high reflectance (more than 99.6%) and high mechanical quality (Q approximately 10,000). We observe cooling of the mechanical oscillator by a factor of more than 30; that is, from room temperature to below 10 K. In addition to purely photothermal effects we identify radiation pressure as a relevant mechanism responsible for the cooling. In contrast with earlier experiments, our technique does not need any active feedback. We expect that improvements of our method will permit cooling ratios beyond 1,000 and will thus possibly enable cooling all the way down to the quantum mechanical ground state of the micromirror.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...