Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(7)2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38610901

RESUMO

Background: Numerous studies have aimed to predict prenatal and neonatal outcomes for pregnancies complicated by congenital cytomegalovirus (CMV). Presently, assessing CMV severity prenatally relies largely on fetal imaging. A controversy exists regarding CMV viral load (VL) and its association with fetal and neonatal sequelae. Objective: To perform a systematic review and meta-analysis investigating the association between CMV DNA VL in amniotic fluid and fetal and neonatal outcomes in pregnancies with congenital CMV. Results: All cohort, case-control and observational studies that compared outcomes of fetuses with congenital CMV and provided information on individual patient CMV VL quantified in copies per milliliter (c/mL) from inception to January 2023 were included, with no geographical or language restrictions. A total of 1251 citations were reviewed with eight studies meeting inclusion criteria and included in meta-analysis. Affected pregnancies had a higher VL in the amniotic fluid compared to those unaffected with a mean difference of 2.2e+7 (range 1.5e+7 to 2.8e+7). In subgroup analysis, the VL was significantly higher in the fetuses, with imaging findings related to CMV compared to asymptomatic fetuses with a mean difference of 4.1e+7 (95% CI 2.8e+7-5.4e+7). However, among babies with congenital CMV, the VL was not significantly different between symptomatic and asymptomatic babies. Conclusions: Amniotic fluid CMV VL is associated with fetal sequalae in congenital CMV, with a higher VL conferring a greater risk for prenatal injury.

2.
J Matern Fetal Neonatal Med ; 35(19): 3640-3645, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33108914

RESUMO

BACKGROUND: Congenital-pulmonary-airway-malformation (CPAM) and bronchopulmonary-sequestration (BPS) are rare conditions. The objective of this study was to describe the sonographic characteristics and prenatal course of fetal lung mass. METHODS: A retrospective study on 20 pregnancies with CPAM and BPS diagnosed during 2018-2018 was performed. Data evaluated included gestational age (GA) at diagnosis, size of lesion, CPAM-volume-ratio (CVR), associated sonographic findings and pregnancy outcome. RESULTS: Fourteen cases of CPAM and six cases of BPS were evaluated. The average GA at diagnosis was 22 weeks'-gestation (range 17-26). 66% were macrocystic-multicystic. Five cases of BPS (71.4%) had other structural anomalies. None of the fetuses with CPAM had additional anomalies. Four pregnancies (20%) underwent termination due to severe hydrops fetalis. Two cases of CPAM (15%) had spontaneous resolution by 30 week's-gestation; three cases (20%) continued to grow during pregnancy and all the rest reached their largest size at 25-28 week's-gestation. Most cases delivered at term (average 37.6 range 32.2-41.4). Two children had lobectomy at 11 and 12 months of life. CONCLUSIONS: Careful follow-up during pregnancy may result in term delivery of adequate-for-gestational-age newborns, with no need for admission to the NICU, with only 10% need for lobectomy during the first year of life.


Assuntos
Sequestro Broncopulmonar , Malformação Adenomatoide Cística Congênita do Pulmão , Sequestro Broncopulmonar/diagnóstico por imagem , Sequestro Broncopulmonar/cirurgia , Criança , Malformação Adenomatoide Cística Congênita do Pulmão/diagnóstico por imagem , Malformação Adenomatoide Cística Congênita do Pulmão/cirurgia , Feminino , Humanos , Recém-Nascido , Pulmão/anormalidades , Pulmão/diagnóstico por imagem , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
3.
J Ultrasound Med ; 40(10): 2165-2171, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33351224

RESUMO

OBJECTIVES: To assess the prenatal growth pattern of the normal kidney contralateral to a multicystic dysplastic kidney (MCDK). METHODS: A retrospective study was conducted in a single referral center over 4 years. Cases diagnosed prenatally as MCDK and confirmed postnatally constituted the study group. For creation of nomograms, only isolated cases of MCDK were included. RESULTS: Sixty-one fetuses had a diagnosis of an MCDK during the study period. After exclusion of cases with associated malformations, 47 fetuses remained, providing 94 measurements for creation of nomograms. The growth pattern of the normal kidney contralateral to an MCDK was linear throughout gestation (percentile = 20.01 + 1.5 gestational age; linear R2  = 0.753; r = 0.868) and was significantly higher during the third trimester (29-38 weeks' gestation) compared to the second trimester (22-28 weeks' gestation; P < .001). A comparison of the growth pattern of the normal kidney contralateral to the MCDK to the growth pattern of a solitary kidney revealed a significant higher compensatory trend during the third trimester (P < .0001). The mean kidney lengths at 22 and 38 weeks' gestation correlated with the 52nd and 88th and with the 84th and 90th percentiles for the normal kidney contralateral to the MCDK and a solitary kidney, respectively. CONCLUSIONS: According to our study, the normal kidney contralateral to an MCDK has a unique growth pattern during intrauterine life, with dominant growth during the third trimester. The exact mechanism for this pattern, in comparison to early renal hypertrophy shown in solitary kidneys, is currently not clear. These data provide relevant information for the multidisciplinary prenatal counseling of future parents regarding the future renal outcome.


Assuntos
Rim Displásico Multicístico , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Rim/diagnóstico por imagem , Rim Displásico Multicístico/diagnóstico por imagem , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
4.
J Ultrasound Med ; 30(9): 1205-10, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21876091

RESUMO

OBJECTIVES: The purpose of this study was to determine the accuracy of sonographic diagnosis of ovarian torsion and the predictive value of typical sonographic signs. METHODS: The study included 63 women attending an ultrasound unit of a tertiary obstetrics and gynecology department in 2002 through 2008 who had suspected ovarian torsion on sonography and subsequently underwent laparoscopy. RESULTS: Sonography had diagnostic accuracy of 74.6% for ovarian torsion. Abnormal ovarian blood flow and the presence of free fluid were the most diagnostically accurate isolated sonographic signs (positive predictive values, 80.0% and 89.2%, respectively; negative predictive values, 46.2% and 46.2%). Using combinations of sonographic signs yielded higher specificity and positive predictive values and lower sensitivity and negative predictive values for ovarian torsion. The diagnostic accuracy was largely affected by the ultrasound operator (mean ± SD, 78.8% ± 16.0%; range, 60.0%-100%). CONCLUSIONS: In the setting of a specialized ultrasound unit, sonographic diagnosis of ovarian torsion had high (74.6%) accuracy compared with previous reports. The absence of typical sonographic signs does not rule out ovarian torsion, especially when the clinical presentation is suggestive. Basing assessments on multiple sonographic signs, including Doppler evaluation, increases the diagnostic specificity.


Assuntos
Doenças Ovarianas/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Adulto , Distribuição de Qui-Quadrado , Diagnóstico Diferencial , Feminino , Humanos , Modelos Logísticos , Doenças Ovarianas/cirurgia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Anormalidade Torcional/cirurgia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA