Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 4561, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402310

RESUMO

This paper evaluates the effectiveness and safety of XEN63 stent, either standalone or in combination with phacoemulsification, in patients with primary open-angle glaucoma (POAG). Eighty eyes from 80 patients with medically uncontrolled POAG were assigned to undergo XEN63 implant. The primary outcome was the surgical success, defined as an intraocular pressure (IOP) lowering from preoperative values ≥ 20% and an IOP absolute value between 6 and 18 mmHg, with or without antiglaucoma medications. Forty-three (53.7%) eyes underwent XEN63-standalone and 37(46.2%) eyes a XEN63 + Phacoemulsification procedure. Success rate was 68.8% (55/80) eyes in the overall study sample, 69.8% (30/43) eyes in the XEN63-standalone group; and 67.6% (25/37) eyes in the XEN63 + Phaco group (p = 0.6133). Preoperative IOP was significantly lowered from 22.1 ± 4.9 mmHg and 19.8 ± 3.7 mmHg to 14.7 ± 5.3 mmHg and 13.8 ± 3.4 mmHg in the XEN63-standalone and XEN63 + Phaco groups, respectively (p < 0.0001 each, respectively); without significant differences between them at any of the time-points measured. Preoperative number of ocular-hypotensive drugs was significantly reduced from 2.3 ± 0.8 to 0.3 ± 0.7 drugs, from 2.5 ± 0.7 to 0.3 ± 0.7 drugs; and from 2.0 ± 0.8 to 0.3 ± 0.7 drugs, in the overall, XEN63-standalone, and XEN63 + Phaco groups, respectively. Regarding safety, 3(42.5%) eyes had transient hypotony at some point during the study, although only in one (1.2%) eye was clinically significant. Four (5.0%) eyes underwent a needling, 4 (5.0%) eyes underwent surgical-bleb-revision, 1 (1.2%) eye required a device replacement and 1 (1.2%) eye a device removal due to maculopathy. XEN63, either alone or in combination with phacoemulsification, significantly lowered IOP and reduced the number of ocular hypotensive medications. The rate of ocular hypotony was relatively high, although it was clinically relevant only in one eye.


Assuntos
Extração de Catarata , Glaucoma de Ângulo Aberto , Hipotensão Ocular , Facoemulsificação , Humanos , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Resultado do Tratamento , Pressão Intraocular , Tonometria Ocular , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Anti-Hipertensivos/efeitos adversos
2.
J Clin Med ; 12(17)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37685554

RESUMO

BACKGROUND: Optic nerve head (ONH) interpretation is a glaucoma screening method which may be influenced by criteria variability. Laguna ONhE software is a low-cost and non-invasive method of ONH analysis. METHODS: We analysed the results of the Laguna ONhE application, interpreting 552 ONH images from the ACRIMA database, publicly available on the Internet, and compared them with the opinion of five experts. Diagnostic agreement was investigated using Cohen's kappa (κ) with 95% confidence. RESULTS: The kappa concordance index obtained with Laguna ONhE and the majority of the experts' criterion (0.77) was significantly higher compared to that obtained with ACRIMA and the majority of the experts' criterion (0.61). In 44.7% of the cases there was absolute agreement among the 5 experts and the Laguna ONhE program. Removing borderline cases from the analysis yielded increased diagnostic agreement (0.81). The area under the receiver operating characteristic (AUROC) of the Laguna ONhE program (0.953, p < 0.001) was not significantly different than AUROC of the majority of the experts' criterion (0.925, p < 0.001), p = 0.052. Individually obtained expert's AUROCs were significantly lower (0.636 to 0.913; p < 0.01). CONCLUSIONS: Laguna ONhE's agreement with the experts is high, particularly where the diagnosis may be more obvious by the appearance of the ONH.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36231937

RESUMO

BACKGROUND: To determine the impacts of continuous positive airway pressure (CPAP) treatment on retinal and choroidal thickness measurement in individuals with obstructive sleep apnea (OSA). METHODS: Participants were 28 patients with OSA treated with CPAP who were enrolled immediately after diagnosis and graded according to the apnea hypopnea index (AHI) determined in an overnight polysomnography. Inclusion criteria were a new diagnosis of OSA and an indication for CPAP. Participants underwent a full ophthalmologic examination including standard automated perimetry (SAP) and optical coherence tomography (OCT) at the levels peripapillary, macular, and choroidal before CPAP onset, and after three and twelve months of CPAP. The data compared before and after treatment were intraocular pressure, SAP, and the thicknesses peripapillary retinal nerve fiber layer (pRNFL), total retinal (TR), retinal ganglion cell layer (RGCL), inner plexiform layer (IPL), photoreceptor layer (PL), and choroidal. RESULTS: After 3 months of CPAP, we observed thickening of the pRNFL (in 5/6 subfields) (p < 0.004) and TR (in 5/9 subfields) (p < 0.010). At 12 months, thickening persisted in these layers, this time affecting 2/6 and 2/9 subfields, respectively (p < 0.012 and p < 0.001, respectively). Choroidal thinning was observed at the temporal level at both 3 and 12 months compared to measurements before starting CPAP treatment (p = 0.014 and p = 0.038, respectively). SAP remained unchanged. Intraocular pressure was higher at 12 months than at 3 months (p = 0.001). CONCLUSIONS: 12 months of CPAP avoids retinal thinning and normalizes choroidal thickness in OSA patients.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Estudos Prospectivos , Células Ganglionares da Retina , Apneia Obstrutiva do Sono/diagnóstico
5.
Prog Brain Res ; 256(1): 99-124, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32958217

RESUMO

The chapter is a review enclosed in the volume "Glaucoma: A pancitopatia of the retina and beyond." No cure exists for glaucoma. Knowledge on the molecular and cellular alterations underlying glaucoma neurodegeneration (GL-ND) includes innovative and path-breaking research on neuroinflammation and neuroprotection. A series of events involving immune response (IR), oxidative stress and gene expression are occurring during the glaucoma course. Uveitic glaucoma (UG) is a prevalent acute/chronic complication, in the setting of chronic anterior chamber inflammation. Managing the disease requires a team approach to guarantee better results for eyes and vision. Advances in biomedicine/biotechnology are driving a tremendous revolution in ophthalmology and ophthalmic research. New diagnostic and imaging modalities, constantly refined, enable outstanding criteria for delimiting glaucomatous neurodegeneration. Moreover, biotherapies that may modulate or inhibit the IR must be considered among the first-line for glaucoma neuroprotection. This review offers the readers useful and practical information on the latest updates in this regard.


Assuntos
Inteligência Artificial , Terapia Biológica , Glaucoma , Inflamação , Degeneração Neural , Uveíte , Glaucoma/diagnóstico por imagem , Glaucoma/imunologia , Glaucoma/metabolismo , Glaucoma/terapia , Humanos , Inflamação/diagnóstico por imagem , Inflamação/imunologia , Inflamação/metabolismo , Inflamação/terapia , Degeneração Neural/diagnóstico por imagem , Degeneração Neural/imunologia , Degeneração Neural/metabolismo , Degeneração Neural/terapia , Uveíte/diagnóstico por imagem , Uveíte/imunologia , Uveíte/metabolismo , Uveíte/terapia
6.
Int J Ophthalmol ; 10(2): 306-309, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28251093

RESUMO

The lamina cribrosa thickness (LCT) could be affected by dynamic changes in its structure. Using Spectral-domain-optical coherence tomography (SD-OCT), we have studied the behaviour of the laminar region in 14 young subjects over 24h. Significant changes in LCT were observed, depending on the time at which the measurement was taken, with the maximum thickness being observed at 7.30 p.m., and the minimum at 7.30 a.m. This finding could suggests a circadian pattern in the LCT thickness in healthy subjects, which could have implications for the classification, diagnosis and prognosis of both normal and glaucomatous subjects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...