1.
Comput Biol Med ; 155: 106655, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36812811

RESUMO

BACKGROUND/AIM: In atrial fibrillation (AF) ablation procedures, it is desirable to know whether a proper disconnection of the pulmonary veins (PVs) was achieved. We hypothesize that information about their isolation could be provided by analyzing changes in P-wave after ablation. Thus, we present a method to detect PV disconnection using P-wave signal analysis. METHODS: Conventional P-wave feature extraction was compared to an automatic feature extraction procedure based on creating low-dimensional latent spaces for cardiac signals with the Uniform Manifold Approximation and Projection (UMAP) method. A database of patients (19 controls and 16 AF individuals who underwent a PV ablation procedure) was collected. Standard 12-lead ECG was recorded, and P-waves were segmented and averaged to extract conventional features (duration, amplitude, and area) and their manifold representations provided by UMAP on a 3-dimensional latent space. A virtual patient was used to validate these results further and study the spatial distribution of the extracted characteristics over the whole torso surface. RESULTS: Both methods showed differences between P-wave before and after ablation. Conventional methods were more prone to noise, P-wave delineation errors, and inter-patient variability. P-wave differences were observed in the standard leads recordings. However, higher differences appeared in the torso region over the precordial leads. Recordings near the left scapula also yielded noticeable differences. CONCLUSIONS: P-wave analysis based on UMAP parameters detects PV disconnection after ablation in AF patients and is more robust than heuristic parameterization. Moreover, additional leads different from the standard 12-lead ECG should be used to detect PV isolation and possible future reconnections better.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Sistema de Condução Cardíaco , Eletrocardiografia , Criocirurgia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
2.
IEEE Trans Biomed Eng ; 69(10): 3029-3038, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35294340

RESUMO

Electrocardiographic Imaging (ECGI) aims to estimate the intracardiac potentials noninvasively, hence allowing the clinicians to better visualize and understand many arrhythmia mechanisms. Most of the estimators of epicardial potentials use a signal model based on an estimated spatial transfer matrix together with Tikhonov regularization techniques, which works well specially in simulations, but it can give limited accuracy in some real data. Based on the quasielectrostatic potential superposition principle, we propose a simple signal model that supports the implementation of principled out-of-sample algorithms for several of the most widely used regularization criteria in ECGI problems, hence improving the generalization capabilities of several of the current estimation methods. Experiments on simple cases (cylindrical and Gaussian shapes scrutinizing fast and slow changes, respectively) and on real data (examples of torso tank measurements available from Utah University, and an animal torso and epicardium measurements available from Maastricht University, both in the EDGAR public repository) show that the superposition-based out-of-sample tuning of regularization parameters promotes stabilized estimation errors of the unknown source potentials, while slightly increasing the re-estimation error on the measured data, as natural in non-overfitted solutions. The superposition signal model can be used for designing adequate out-of-sample tuning of Tikhonov regularization techniques, and it can be taken into account when using other regularization techniques in current commercial systems and research toolboxes on ECGI.


Assuntos
Eletrocardiografia , Pericárdio , Algoritmos , Animais , Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Humanos , Distribuição Normal , Pericárdio/diagnóstico por imagem
3.
Sensors (Basel) ; 19(18)2019 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-31540042

RESUMO

During the last decades there has been a rapidly growing elderly population and the number of patients with chronic heart-related diseases has exploded. Many of them (such as those with congestive heart failure or some types of arrhythmias) require close medical supervision, thus imposing a big burden on healthcare costs in most western economies. Specifically, continuous or frequent Arterial Blood Pressure (ABP) and electrocardiogram (ECG) monitoring are important tools in the follow-up of many of these patients. In this work, we present a novel remote non-ambulatory and clinically validated heart self-monitoring system, which allows ABP and ECG monitoring to effectively identify clinically relevant arrhythmias. The system integrates digital transmission of the ECG and tensiometer measurements, within a patient-comfortable support, easy to recharge and with a multi-function software, all of them aiming to adapt for elderly people. The main novelty is that both physiological variables (ABP and ECG) are simultaneously measured in an ambulatory environment, which to our best knowledge is not readily available in the clinical market. Different processing techniques were implemented to analyze the heart rhythm, including pause detection, rhythm alterations and atrial fibrillation, hence allowing early detection of these diseases. Our results achieved clinical quality both for in-lab hardware testing and for ambulatory scenario validations. The proposed active assisted living (AAL) Sensor-based system is an end-to-end multidisciplinary system, fully connected to a platform and tested by the clinical team from beginning to end.


Assuntos
Moradias Assistidas , Coração/fisiologia , Monitorização Fisiológica/instrumentação , Telemedicina/instrumentação , Algoritmos , Eletrocardiografia , Humanos , Aplicativos Móveis , Processamento de Sinais Assistido por Computador , Interface Usuário-Computador
4.
Sensors (Basel) ; 18(5)2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29723990

RESUMO

Despite the wide literature on R-wave detection algorithms for ECG Holter recordings, the long-term monitoring applications are bringing new requirements, and it is not clear that the existing methods can be straightforwardly used in those scenarios. Our aim in this work was twofold: First, we scrutinized the scope and limitations of existing methods for Holter monitoring when moving to long-term monitoring; Second, we proposed and benchmarked a beat detection method with adequate accuracy and usefulness in long-term scenarios. A longitudinal study was made with the most widely used waveform analysis algorithms, which allowed us to tune the free parameters of the required blocks, and a transversal study analyzed how these parameters change when moving to different databases. With all the above, the extension to long-term monitoring in a database of 7-day Holter monitoring was proposed and analyzed, by using an optimized simultaneous-multilead processing. We considered both own and public databases. In this new scenario, the noise-avoid mechanisms are more important due to the amount of noise that exists in these recordings, moreover, the computational efficiency is a key parameter in order to export the algorithm to the clinical practice. The method based on a Polling function outperformed the others in terms of accuracy and computational efficiency, yielding 99.48% sensitivity, 99.54% specificity, 99.69% positive predictive value, 99.46% accuracy, and 0.85% error for MIT-BIH arrhythmia database. We conclude that the method can be used in long-term Holter monitoring systems.

5.
Sensors (Basel) ; 17(11)2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-29068362

RESUMO

Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported, showing the statistical and temporal correspondences and properties with respect to EER signals used to create the gold standard for clinical noise. The proposed noise maps, together with the statistical consistency of the characterization of the noise clinical severity, paves the way towards forthcoming systems providing us with noise maps of the noise clinical severity, allowing the user to process different ECG segments with different techniques and in terms of different measured clinical parameters.


Assuntos
Eletrocardiografia/métodos , Algoritmos , Artefatos , Eletrocardiografia/normas , Eletrocardiografia Ambulatorial , Humanos , Razão Sinal-Ruído
6.
IEEE Trans Biomed Eng ; 64(2): 302-309, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27101595

RESUMO

OBJECTIVE: Heart rate turbulence (HRT) has been successfully explored for cardiac risk stratification. While HRT is known to be influenced by the heart rate (HR) and the coupling interval (CI), nonconcordant results have been reported on how the CI influences HRT. The purpose of this study is to investigate HRT changes in terms of CI and HR by means of an especially designed protocol. METHODS: A dataset was acquired from 11 patients with structurally normal hearts for which CI was altered by different pacing trains and HR by isoproterenol during electrophysiological study (EPS). The protocol was designed so that, first, the effect of HR changes on HRT and, second, the combined effect of HR and CI could be explored. As a complement to the EPS dataset, a database of 24-h Holters from 61 acute myocardial infarction (AMI) patients was studied for the purpose of assessing risk. Data analysis was performed by using different nonlinear ridge regression models, and the relevance of model variables was assessed using resampling methods. The EPS subjects, with and without isoproterenol, were analyzed separately. RESULTS: The proposed nonlinear regression models were found to account for the influence of HR and CI on HRT, both in patients undergoing EPS without isoproterenol and in low-risk AMI patients, whereas this influence was absent in high-risk AMI patients. Moreover, model coefficients related to CI were not statistically significant, p > 0.05, on EPS subjects with isoproterenol. CONCLUSION: The observed relationship between CI and HRT, being in agreement with the baroreflex hypothesis, was statistically significant ( ), when decoupling the effect of HR and normalizing the CI by the HR. SIGNIFICANCE: The results of this study can help to provide new risk indicators that take into account physiological influence on HRT, as well as to model how this influence changes in different cardiac conditions.


Assuntos
Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS