Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiol Med ; 122(2): 81-87, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27744607

RESUMO

PURPOSE: The aim of our study was to evaluate factors influencing effectiveness of percutaneous microwave ablation (MWA) in patients with small hepatocellular carcinoma (HCC) (<3 cm). MATERIALS AND METHODS: Between December 2007 and August 2015, 49 patients with 65 previously histological typed HCC were treated in a total of 61 sessions. Tumours were subdivided into central (>3 cm from the capsule) (n = 22) and peripheral (<3 cm from the capsule) (n = 43). Imaging follow-up was performed at 1, 3, 6, and 12 months after treatment, then annually. Mean follow-up period was 18 months (range 1-55). Location of the lesion, age, sex, and underlying disease of the patients was analyzed and related with efficacy. RESULTS: Technical success was obtained in all cases. Residual disease was registered in 21 lesions (32.3 %): 13 were peripheral and 8 were central. Twelve of them were retreated with percutaneous MWA. Local recurrence was recorded in 8 lesions (12.3 %): 5 were retreated with MWA. No significant difference in terms of effectiveness was observed in lesions located in a central position and those situated in the peripheral position. Age, sex, and underlying disease not influenced results. Only one major complication was observed. The rate of minor complications was 24.5 %. Mortality at 30 days was 0 %. CONCLUSIONS: Our results encourage the role of MWA in the treatment of small HCC. More numerous series and randomized studies are necessary to state the role of MWA and to select cases in which MWA may be more effective and safer than RFA.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/métodos , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Radiol Case Rep ; 11(12): 8-15, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29290905

RESUMO

Pelvic kidney is a relatively common renal malformation as well as duplex kidney; however, the unilateral coexistence of these abnormalities is not frequently found. We present a case of a young woman with a history of hypertension in whom a pelvic and dysmorphic left kidney was discovered during ultrasound examination performed for the study of the renal arteries. Magnetic resonance imaging and computed tomography imaging revealed a duplex pelvic kidney. This combination is very rare; we have not found a similar case reported in the literature.


Assuntos
Hipertensão/etiologia , Nefropatias/diagnóstico por imagem , Rim/anormalidades , Rim/diagnóstico por imagem , Adulto , Feminino , Humanos , Nefropatias/complicações , Nefropatias/congênito
3.
Skeletal Radiol ; 45(12): 1669-1676, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27699478

RESUMO

OBJECTIVE: To demonstrate the feasibility of percutaneous nucleoplasty procedures at L5/S1 level using cone beam CT (CBCT) and its associated image guidance technology for the treatment of lumbar disc herniation (LDH). MATERIALS AND METHODS: We retrospectively reviewed 25 cases (20 men, 5 women) of LDH at L5/S1 levels. CBCT as guidance imaging was chosen after a first unsuccessful fluoroscopy attempt that was related to complex anatomy (n = 15), rapid pathological changes due to degenerative diseases (n = 7) or both (n = 3). Technical success, defined as correct needle positioning in the target LDH, and safety were evaluated; overall procedure time and radiation dose were registered. A visual analog scale (VAS) was used to evaluate pain and discomfort pre-intervention after 1 week and 1, 3, and 6 months after the procedure. RESULTS: Technical success was 100 %; using CBCT as guidance imaging the needle was correctly positioned at the first attempt in 20 out of 25 patients. Neither major nor minor complications were registered during or after the procedure. The average procedure time was 11 min and 56 s (range, 9-15 min), whereas mean procedural radiation dose was 46.25 Gy.cm2 (range 38.10-52.84 Gy.cm2), and mean fluoroscopy time was 5 min 34 s (range 3 min 40 s to 6 min 55 s). The VAS pain score decreased significantly from 7.6 preoperatively to 3.9 at 1 week, 2.8 at 1 month, 2.1 at 3 months, and 1.6 at 6 months postoperatively. CONCLUSIONS: CBCT-guided percutaneous nucleoplasty is a highly effective technique for LDH with acceptable procedure time and radiation dose.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Feminino , Fluoroscopia , Humanos , Vértebras Lombares , Masculino , Agulhas , Procedimentos Ortopédicos , Medição da Dor , Posicionamento do Paciente , Estudos Retrospectivos , Software , Cirurgia Assistida por Computador , Resultado do Tratamento
4.
Ann Gastroenterol ; 29(4): 460-465, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27708511

RESUMO

Percutaneous radiofrequency ablation (RFA) can be as effective as surgical resection in terms of overall survival and recurrence-free survival rates in patients with small hepatocellular carcinoma (HCC). Effectiveness of RFA is adversely influenced by heat-sink effect. Other ablative therapies could be considered for larger tumors or for tumors located near the vessels. In this regard, recent improvements in microwave energy delivery systems seem to open interesting perspectives to percutaneous ablation, which could become the ablation technique of choice in the near future. Microwave ablation (MWA) has the advantages of possessing a higher thermal efficiency. It has high efficacy in coagulating blood vessels and is a relatively fast procedure. The time required for ablation is short and the shape of necrosis is elliptical with the older systems and spherical with the new one. There is no heat-sink effect and it can be used to ablate tumors adjacent to major vessels. These factors yield a large ablation volume, and result in good local control and fewer complications. This review highlights the most relevant updates on MWA in the treatment of small (<3 cm) HCC. Furthermore, we discuss the possibility of MWA as the first ablative choice, at least in selected cases.

5.
Radiol Med ; 121(8): 675-80, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27138011

RESUMO

AIM: The aim of the study was to establish if a novel tablet ultrasound (US) may replace a high-end US machine during routine interventional radiology activities. MATERIALS AND METHODS: Thirty consecutive patients were evaluated by two operators comparing the performance of the new US tablet system (VISIQ, Philips Healthcare) against a high-end US system (iU22, Philips Healthcare) using a curved probe (C5-2). A structured questionnaire was used to rank on a 4-point scale the ability of each system to locate a target as detected by previous examinations and visualize needles and path during an interventional procedure. Necessity for conversion from the tablet US to the high-end US system was registered; body mass index (BMI) was annotated for each patient. RESULTS: Agreement between the operators was found for every patient. Mean patient BMI was 25 (range 17-34). Image quality of the tablet US was considered insufficient in 1 case to visualize the target and in another case to visualize the needle. Mean target image quality was superior with the high-end US system, while needle visibility scored higher with the tablet US. Conversion to the high-end system was registered in 40 % of cases: in most cases (66.6 %) the decision was due to the absence of a dedicated needle guide for the tablet US. CONCLUSIONS: The novel tablet US was found to provide sufficient image quality for the majority of routine interventional procedures. Dedicated accessories and additional experience with this new generation US device may be needed to replace bulky high-end US systems.


Assuntos
Ultrassonografia de Intervenção/instrumentação , Biópsia por Agulha/instrumentação , Índice de Massa Corporal , Ablação por Cateter , Drenagem , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Masculino , Inquéritos e Questionários
6.
Radiol Med ; 118(6): 949-61, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23892957

RESUMO

PURPOSE: The purpose of our study was to evaluate technical success, effectiveness and safety of microwave ablation (MWA) in patients with unresectable liver metastases, where radiofrequency ablation (RFA) presents some limits. MATERIALS AND METHODS: Twenty-five patients (17 men, 8 women) with 31 liver metastases >3 cm or located near vessels (>3 mm) were treated in a total of 29 sessions. Tumours were subdivided as follows: colorectal metastases (n=21) and no colorectal metastases (n=10). All procedures were performed percutaneously under ultrasound (US) guidance. Follow-up was performed with computed tomography (CT) scan at 1, 3, 6 and 12 months after treatment; mean follow-up period was 12.04 (range, 3-36) months. Technical success, mean disease-free survival, effectiveness and safety were evaluated. RESULTS: Technical success was obtained in all cases. Mean disease-free survival was of 20.5 months. Local recurrence was recorded in 12.9% of metastases treated (4/31). No major complications were recorded. The rate of minor complications was 44.8% (13/29 sessions). Mortality at 30 days was 0%. CONCLUSIONS: Percutaneous MWA of liver metastases >3 cm or located near vessels (>3 mm) can be considered a valid and safe option, probably preferable to RFA. Further studies are required to confirm these encouraging initial results.


Assuntos
Ablação por Cateter/métodos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/patologia , Meios de Contraste , Intervalo Livre de Doença , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ácidos Tri-Iodobenzoicos , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...