Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Sci Rep ; 12(1): 9223, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35654982

RESUMO

We report pump-probe transient absorption measurements addressing the photocycle of the Germanium lone pair center (GLPC) point defect with an unprecedented time resolution. The GLPC is a model point defect with a simple and well-understood electronic structure, highly relevant for several applications. Therefore, a full explanation of its photocycle is fundamental to understand the relaxation mechanisms of such molecular-like systems in solid state. The experiment, carried out exciting the sample resonantly with the ultraviolet (UV) GLPC absorption band peaked at 5.1 eV, gave us the possibility to follow the defect excitation-relaxation dynamics from the femto-picosecond to the nanosecond timescale in the UV-visible range. Moreover, the transient absorption signal was studied as a function of the excitation photon energy and comparative experiments were conducted on highly- and weakly-germanium doped silica glasses. The results offer a comprehensive picture of the relaxation dynamics of GLPC and allow observing the interplay between electronic transitions localized on the defect and those related to bandgap transitions, providing a clear evidence that the role of dopant high concentration is not negligible in the earliest dynamics.


Assuntos
Germânio , Fótons , Dióxido de Silício
2.
Opt Lett ; 44(21): 5286-5289, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31674989

RESUMO

For some infrastructures such as oil and gas extraction boreholes or radioactive waste repositories, where distributed optical fiber sensors are employed to grant the safety of the facilities, the presence of gas species such as hydrogen or deuterium is one of the most relevant parameters to monitor. The possibility of employing the same kind of sensors for this purpose is of special interest, reducing the cost by employing a single interrogator, able to measure multiple parameters by simply employing adequate sensing fibers. To meet this goal, we present here a chemical sensor based on chirped-pulse phase-sensitive optical time-domain reflectometry (CP-φOTDR), which is able to detect these species while they diffuse into the silica fiber. The ability of chirped-pulse φOTDR to measure a change in refractive index with sensitivity around 10-8 has allowed determining hydrogen concentration with accuracy on the order of 10-3 mol/m3 and spatial resolution ∼6 m. Another experiment provides an indirect measurement of the solubility of deuterium in a standard telecom-grade optical fiber, which is found to be around 1.47×1024 m3/bar.

3.
Sci Rep ; 9(1): 16376, 2019 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-31704964

RESUMO

Optical fibers hold promise for accurate dosimetry in small field proton therapy due to their superior spatial resolution and the lack of significant Cerenkov contamination in proton beams. One known drawback for most scintillation detectors is signal quenching in areas of high linear energy transfer, as is the case in the Bragg peak region of a proton beam. In this study, we investigated the potential of innovative optical fiber bulk materials using the sol-gel technique for dosimetry in proton therapy. This type of glass is made of amorphous silica (SiO[Formula: see text]) and is doped with Gd[Formula: see text] ions and possesses very interesting light emission properties with a luminescence band around 314 nm when exposed to protons. The fibers were manufactured at the University of Lille and tested at the TRIUMF Proton Therapy facility with 8.2-62.9 MeV protons and 2-6 nA of extracted beam current. Dose-rate dependence and quenching were measured and compared to other silica-based fibers also made by sol-gel techniques and doped with Ce[Formula: see text] and Cu[Formula: see text]. The three fibers present strong luminescence in the UV (Gd) or visible (Cu,Ce) under irradiation, with the emission intensities related directly to the proton flux. In addition, the 0.5 mm diameter Gd[Formula: see text]-doped fiber shows superior resolution of the Bragg peak, indicating significantly reduced quenching in comparison to the Ce[Formula: see text] and Cu[Formula: see text] fibers with a Birks' constant, k[Formula: see text], of (0.0162 [Formula: see text] 0.0003) cm/MeV in comparison to (0.0333 [Formula: see text] 0.0006) cm/MeV and (0.0352 [Formula: see text] 0.0003) cm/MeV, respectively. To our knowledge, this is the first report of such an interesting k[Formula: see text] for a silica-based optical fiber material, showing clearly that this fiber presents lower quenching than common plastic scintillators. This result demonstrates the high potential of this inorganic fiber material for proton therapy dosimetry.


Assuntos
Gadolínio , Fibras Ópticas , Terapia com Prótons , Radiometria/instrumentação , Humanos , Transferência Linear de Energia , Luminescência , Imagens de Fantasmas , Prótons , Radiometria/métodos , Dióxido de Silício
4.
Opt Express ; 27(15): 21608-21621, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510234

RESUMO

Coupled temperature and γ-ray influence on Brillouin (PPP-BOTDA) and Rayleigh (TW-COTDR) scatterings are quantified. Aging tests of these distributed strain measuring systems are performed on-line, up to 1 MGy, at room temperature, 80  ∘C, 100  ∘C and 120  ∘C. Brillouin and Rayleigh frequency shifts remain identical regardless of the temperature: 3 MHz (2 MHz) and 7 GHz (3 GHz) for Ge-doped (respectively F-doped) fiber at 1 MGy. Meanwhile, radiation-induced attenuation is diminished because of the higher temperature; hence, the maximal distance range is less deteriorated. These tests help to explain the origin of the Brillouin frequency shift under γ-rays, with an acoustic velocity variation of about 1 m/s in 1 MGy irradiated samples.

5.
Appl Opt ; 58(22): 6165-6172, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31503942

RESUMO

We studied the impact of ionizing radiation at high dose levels (megagray, MGy) on the photometric budget of a radiation-resistant complementary metal oxide semi-conductor (CMOS)-based camera. This is achieved by measuring the radiation-induced degradation of each subpart, namely its illumination system, its optical system, and its CMOS image sensor. The acquired experimental results allow performing a rather realistic simulation of the radiation effects at the system level. Thanks to appropriate mitigation techniques, limited image darkening and color change are obtained at MGy dose levels. The presented results confirm the feasibility of a CMOS-based camera able to resist to MGy dose level of ionizing radiations with an acceptable degradation of the image quality, opening the way to its implementation in the most challenging harsh environments.

6.
Nat Commun ; 10(1): 3522, 2019 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-31387994

RESUMO

Apart from being key structures of modern microelectronics, metal-insulator-semiconductor (MIS) junctions are highly promising electrodes for artificial leaves, i.e. photoelectrochemical cells that can convert sunlight into energy-rich fuels. Here, we demonstrate that homogeneous Si/SiOx/Ni MIS junctions, employed as photoanodes, can be functionalized with a redox-active species and simultaneously converted into high-photovoltage inhomogeneous MIS junctions by electrochemical dissolution. We also report on the considerable enhancement of performance towards urea oxidation, induced by this process. Finally, we demonstrate that both phenomena can be employed synergistically to design highly-efficient Si-based photoanodes. These findings open doors for the manufacturing of artificial leaves that can generate H2 under solar illumination using contaminated water.

7.
Benef Microbes ; 10(5): 497-509, 2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31090458

RESUMO

Microbial metabolism in the gut may alter human bile acid metabolism in a way that beneficially affects lipid homeostasis and therefore cardiovascular disease risk. Deconjugation of bile acids by microbes is thought to be key to this mechanism but has yet to be characterised in blood and stool while observing lipid markers. The aim of this study was to determine the effect of 3 different probiotic strains on plasma and stool bile acids in the context of lipid and glucose metabolism. In this 18-week, randomised, double-blind crossover study, healthy adults (53±8 years) with a high waist circumference underwent a 1-week pre-baseline period and were then randomised to receive 1 capsule/day of Bacillus subtilis R0179 (2.5×109 cfu/capsule; n=39), Lactobacillus plantarum HA-119 (5×109 cfu/capsule; n=38), Bifidobacterium animalis subsp. lactis B94 (5×109 cfu/capsule; n=37) or placebo for 6 weeks. Following a 3-week washout and second pre-baseline week, participants were crossed to the other intervention for 6 weeks followed by a 1-week post-intervention period. Blood and stool samples were collected at the beginning and end of each intervention to measure bile acids, serum lipid profiles, and glucose and insulin levels. Data from the placebo intervention were combined for all participants for analyses. In obese participants, the difference (final-baseline) in the sum of deconjugated plasma bile acids was greater with consumption of B. subtilis (691±378 nmol/l, P=0.01) and B. lactis (380±165 nmol/l, P=0.04) than with placebo (98±176 nmol/l, n=57). No significant differences were observed for any probiotics for stool bile acids, serum lipids, blood glucose or insulin. These data suggest that B. subtilis and B. lactis had no effect on glucose metabolism or serum cholesterol but increased deconjugated plasma bile acids in obese individuals. Additional studies should be conducted to confirm these findings and explore potential mechanisms. This trial was registered at clinicaltrials.gov as NCT01879098.


Assuntos
Ácidos e Sais Biliares/sangue , Fármacos Gastrointestinais/administração & dosagem , Obesidade/terapia , Plasma/química , Probióticos/administração & dosagem , Adulto , Bacillus subtilis/crescimento & desenvolvimento , Bifidobacterium animalis/crescimento & desenvolvimento , Estudos Cross-Over , Método Duplo-Cego , Fezes/química , Feminino , Humanos , Lactobacillus plantarum/crescimento & desenvolvimento , Masculino , Pessoa de Meia-Idade , Placebos/administração & dosagem , Resultado do Tratamento
8.
Sci Rep ; 9(1): 7126, 2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-31073141

RESUMO

Synthetic vitreous silica is currently the preferred material for the production of optical fibres because of the several excellent properties of this glass, e.g. high transmission in the visible and IR domains, high mechanical strength, chemical durability, and ease of doping with various materials. For instance, fiber lasers and amplifiers exploit the light amplification properties provided by rare-earth ions employed as dopants in the core of silica-based optical fibers. The structure and composition of the nearest neighbor shell surrounding rare-earth ions in silica-based optical fibers and amplifiers have been intensively debated in the last decade. To reduce aggregation effects between rare-earth ions, co-dopants such as phosphorus and aluminium are added as structural modifiers; phosphorus-doping, in particular, has proved to be very efficient in dissolving rare-earth ions. In this work, we provide further insights concerning the embedding of P atoms into the silica network, which may be relevant for explaining the ease of formation of a phosphorus pentoxide nearest-neighbor shell around a rare-earth dopant. In particular, by means of first-principles calculations, we discuss alternative models for an irradiation (UV, x-, γ-rays) induced paramagnetic center, i.e. the so called room-temperature phosphorus-oxygen-hole center, and its precursors. We report that the most likely precursor of a room-temperature phosphorus-oxygen-hole center comprises of a micro-cluster of a few (at least two) neighboring phosphate tetrahedra, and correspondingly that the occurrence of isolated [(O-)2P(=O)2]- units is unlikely even at low P-doping concentrations. In fact, this work predicts that the symmetric stretching of P=O bonds in isolated [(O-)2P(=O)2]- units appears as a Raman band at a frequency of ~1110 cm-1, and only by including at least another corner-sharing phosphate tetrahedron, it is shown to shift to higher frequencies (up to ~40 cm-1) due to the shortening of P=O bonds, thereby leading to an improved agreement with the observed Raman band located at ~1145 cm-1.

9.
Regul Toxicol Pharmacol ; 94: 245-251, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29410076

RESUMO

Salicylic acid (SA) has a long history of safe use as ingredient in topical cosmetic products. In 2016, the Committee for Risk Assessment of the European Chemicals Agency proposed to classify SA as a Category 2 reproductive toxicant based on adverse developmental effects in animal toxicity studies. This hazard-based classification (based on mg/kg doses) requires a reassessment of the safety of the current SA concentrations in cosmetic consumer products. Herein, a safety reassessment was performed in which margins of safety were calculated based on literature data on the NOAEL plasma exposure levels from animal reproductive toxicity studies with ASA (rapidly converts to SA in plasma), human SA plasma levels from oral exposure to ASA and human dermal exposure to SA-containing cosmetic products. In addition, a literature review was performed, which shows that there are no adverse developmental effects despite extensive human clinical oral use of ASA up to the maximum recommended therapeutic doses. The plasma exposure-based safety assessment for SA combined with an absence of any clinical health risk with oral ASA use in the literature supports that there is an acceptable margin of safety for the consumer exposure to SA as authorized in the current EU cosmetic regulation.


Assuntos
Cosméticos/farmacocinética , Cosméticos/toxicidade , Exposição Materna , Ácido Salicílico/farmacocinética , Ácido Salicílico/toxicidade , Administração Oral , Administração Tópica , Animais , Disponibilidade Biológica , Qualidade de Produtos para o Consumidor , Feminino , Humanos , Macaca mulatta , Troca Materno-Fetal , Nível de Efeito Adverso não Observado , Gravidez , Ratos Wistar , Medição de Risco , Ácido Salicílico/sangue
11.
Sci Rep ; 7(1): 8766, 2017 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-28821768

RESUMO

We present an innovative architecture of a Rayleigh-based optical fibre sensor for the monitoring of water level and temperature inside storage nuclear fuel pools. This sensor, able to withstand the harsh constraints encountered under accidental conditions such as those pointed-out during the Fukushima-Daiichi event (temperature up to 100 °C and radiation dose level up to ~20 kGy), exploits the Optical Frequency Domain Reflectometry technique to remotely monitor a radiation resistant silica-based optical fibre i.e. its sensing probe. We validate the efficiency and the robustness of water level measurements, which are extrapolated from the temperature profile along the fibre length, in a dedicated test bench allowing the simulation of the environmental operating and accidental conditions. The conceived prototype ensures an easy, practical and no invasive integration into existing nuclear facilities. The obtained results represent a significant breakthrough and comfort the ability of the developed system to overcome both operating and accidental constraints providing the distributed profiles of the water level (0-to-5 m) and temperature (20-to-100 °C) with a resolution that in accidental condition is better than 3 cm and of ~0.5 °C respectively. These new sensors will be able, as safeguards, to contribute and reinforce the safety in existing and future nuclear power plants.

12.
Nanotechnology ; 28(19): 195202, 2017 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-28345535

RESUMO

In this work we present an extensive investigation of nanoscale physical phenomena related to oxygen-deficient centers (ODCs) in silica and Ge-doped silica by means of first-principles calculations, including nudged-elastic band, electron paramagnetic resonance parameters calculations, and many-body perturbation theory (GW and Bethe-Salpeter equation) techniques. We show that by neutralizing positively charged oxygen monovacancies we can obtain model structures of twofold Si and Ge defects of which the calculated absorption spectra and singlet-to-triplet transitions are in excellent agreement with the experimental optical absorption and photo-luminescence data. In particular we provide an exhaustive analysis of the main exciton peaks related to the presence of twofold defects including long-range correlation effects. By calculating the reaction pathways and energy barriers necessary for the interconversion, we advance a double precursory origin of the [Formula: see text] and Ge(2) centers as due to the ionization of neutral oxygen monovacancies (Si-Si and Ge-Si dimers) and as due to the ionization of twofold Si and Ge defects. Furthermore two distinct structural conversion mechanisms are found to occur between the neutral oxygen monovacancy and the twofold Si (and Ge) atom configurations. Such conversion mechanisms allow to explain the radiation induced generation of the ODC(II) centers, their photobleaching, and also their generation during the drawing of optical fibers.

13.
Arch Pediatr ; 24(3): 254-259, 2017 Mar.
Artigo em Francês | MEDLINE | ID: mdl-28161232

RESUMO

Hemophagocytic lymphohistiocytosis (HLH) is a rare and severe syndrome usually associated with a cytotoxicity deficiency, which leads to an excess of immune response driven by activated macrophages and cytotoxic T cells. In children, HLH can be genetic, as part of a familial lymphohistiocytosis, or secondary: the most frequent causes are systemic-onset juvenile idiopathic arthritis, hematological malignancies, and severe infections, especially with Ebstein-Barr virus or leishmaniosis. We report on the case of a 3-year-old girl with no past medical history, who presented inaugural Pseudomonas aeruginosa maxillary osteitis, with secondary HLH. The rarity of this osteitis, the characteristics of the pathogen, and the onset of HLH oriented the diagnosis toward primary immunodeficiencies, malignancies, or systemic diseases. Steroids were initiated at 2mg/kg/day and were very effective in improving the systemic symptoms. Antibiotic therapy was continued unchanged. A few days after discontinuation of steroids, while the patient was still under antibiotics, she presented with erythroderma. Skin biopsy revealed eosinophil infiltrate in line with the diagnosis of a drug reaction with eosinophilia and systemic symptoms (DRESS), even though we only observed very transient eosinophilia, up to 0.98G/L, during HLH. Stopping antibiotics normalized the symptoms without using systemic corticosteroids. Patch tests confirmed an allergy to piperacillin. These atypical manifestations of DRESS underline that causative diagnosis of HLH is challenging, and DRESS syndrome should be considered.


Assuntos
Síndrome de Hipersensibilidade a Medicamentos/diagnóstico , Linfo-Histiocitose Hemofagocítica/diagnóstico , Doenças Maxilares/diagnóstico , Osteíte/diagnóstico , Piperacilina/efeitos adversos , Piperacilina/uso terapêutico , Infecções por Pseudomonas/diagnóstico , Pseudomonas aeruginosa , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Linfo-Histiocitose Hemofagocítica/tratamento farmacológico , Doenças Maxilares/tratamento farmacológico , Osteíte/tratamento farmacológico , Testes do Emplastro , Infecções por Pseudomonas/tratamento farmacológico
14.
Nanoscale ; 9(5): 1799-1804, 2017 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-28098295

RESUMO

The immersion of oxide-free Si surfaces in MoS42- aqueous solutions induces their spontaneous decoration with isolated MoOx nanoparticles (NPs). The process is versatile and was used on planar Si (100) as well as on antireflective Si (111) micro-pyramid (SimPy) arrays. The NP decoration does not affect the optical properties of the surface in the visible range and improves the performance of the hydrogen evolution reaction (HER) under simulated sunlight. The simplicity and the scalability of the technique make it highly promising for the fabrication of catalytically active photoelectrodes. More specifically, the MoOx-decorated SimPy produced H2 at a rate of 11 µmol cm-2 min-1 with a faradaic efficiency higher than 90% at -0.35 V vs. RHE. Furthermore, this process can be of great interest for other applications in high-performance electronic devices.

15.
Rev Sci Instrum ; 87(11): 113901, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910696

RESUMO

An innovative experimental setup, PELIICAEN, allowing the modification of materials and the study of the effects induced by multiply charged ion beams at the nanoscale is presented. This ultra-high vacuum (below 5 × 10-10 mbar) apparatus is equipped with a focused ion beam column using multiply charged ions and a scanning electron microscope developed by Orsay Physics, as well as a scanning probe microscope. The dual beam approach coupled to the scanning probe microscope achieves nanometer scale in situ topological analysis of the surface modifications induced by the ion beams. Preliminary results using the different on-line characterization techniques to study the formation of nano-hillocks on silicon and mica substrates are presented to illustrate the performances of the setup.

17.
Benef Microbes ; 7(3): 327-36, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26839075

RESUMO

Psychological stress is associated with gastrointestinal (GI) distress. This secondary analysis from a randomised, double-blind, placebo-controlled study examined whether three different probiotics could normalise self-reported stress-associated GI discomfort and reduce overall self-reported stress. Undergraduate students (n=581) received Lactobacillus helveticus R0052, Bifidobacterium longum ssp. infantis R0033, Bifidobacterium bifidum R0071, or placebo. Participants self-reported 2 outcomes for a 6-week period, which included final academic exams: daily level of stress (0=no stress to 10=extremely stressed) and weekly three diarrhoea-related symptoms (DS, 1=no discomfort to 7=severe discomfort) using the GI Symptom Rating Scale. Self-reported stress was positively related to DS (P=0.0068). Mean DS scores were lower with B. bifidum versus placebo at week 2 at the average level of stress and the average body mass index (BMI). DS scores were lower with B. bifidum at week 5 versus week 0 and 1 and with B. infantis R0033 at week 6 versus week 0. DS scores were higher when antibiotics were used in the prior week with placebo (P=0.0092). DS were not different with or without antibiotic use with the probiotics. Only B. bifidum had an effect on self-reported stress scores (P=0.0086). The self-reported stress score was also dependent on hours of sleep per day where it decreased by 0.13 for each additional hour of sleep. During a stressful period, B. bifidum R0071 decreases DS and self-reported stress scores. This trial was registered at clinicaltrials.gov as NCT01709825.


Assuntos
Bifidobacterium bifidum/imunologia , Diarreia/patologia , Diarreia/terapia , Probióticos/administração & dosagem , Estresse Fisiológico , Bifidobacterium longum/imunologia , Método Duplo-Cego , Feminino , Humanos , Lactobacillus helveticus/imunologia , Masculino , Placebos/administração & dosagem , Estudantes , Inquéritos e Questionários , Resultado do Tratamento , Estados Unidos
18.
Curr Oncol ; 23(6): e605-e614, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28050151

RESUMO

The annual Eastern Canadian Gastrointestinal Cancer Consensus Conference 2016 was held in Montreal, Quebec, 5-7 February. Experts in radiation oncology, medical oncology, surgical oncology, and infectious diseases involved in the management of patients with gastrointestinal malignancies participated in presentations and discussion sessions for the purpose of developing the recommendations presented here. This consensus statement addresses multiple topics: ■ Follow-up and survivorship of patients with resected colorectal cancer■ Indications for liver metastasectomy■ Treatment of oligometastases by stereotactic body radiation therapy■ Treatment of borderline resectable and unresectable pancreatic cancer■ Transarterial chemoembolization in hepatocellular carcinoma■ Infectious complications of antineoplastic agents.

19.
Opt Lett ; 40(20): 4571-4, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26469566

RESUMO

We investigate the radiation effects on germanosilicate optical fiber acting as the sensing element of optical frequency domain reflectometry devices. Thanks to a new setup permitting to control temperature during irradiation, we evaluate the changes induced by 10 keV x rays on their Rayleigh response up to 1 MGy in a temperature range from -40°C up to 75°C. Irradiation at fixed temperature points out that its measure is reliable during both irradiation and the recovery process. Mixed temperature and radiation measurements show that changing irradiation temperature leads to an error in distributed measurements that depends on the calibration procedure. These results demonstrate that Rayleigh-based optical fiber sensors are very promising for integration in harsh environments.

20.
Opt Express ; 23(15): 18997-9009, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367563

RESUMO

Vulnerability of Optical Frequency Domain Reflectometry (OFDR) based sensors to high γ-ray doses (up to 10 MGy) is evaluated with a specific issue of a radiation-hardened temperature and strain monitoring system for nuclear industry. For this, we characterize the main radiation effects that are expected to degrade the sensor performances in such applicative domain: the radiation-induced attenuation (RIA), the possible evolution with the dose of the Rayleigh scattering phenomenon as well as its dependence on temperature and strain. This preliminary investigation is done after the irradiation and for five different optical fiber types covering the range from radiation-hardened fibers to highly radiation sensitive ones. Our results show that at these high dose levels the scattering mechanism at the basis of the used technique for the monitoring is unaffected (changes below 5%), authorizing acceptable precision on the temperature or strain measurements. RIA has to be considered as it limits the sensing range. From our vulnerability study, the OFDR sensors appear as promising candidates for nuclear industry even at doses as high as 10 MGy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...