Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30630744

RESUMO

OBJECTIVE: 18F-Fluoro-L-dihydroxyphenylalanine (18F-DOPA) PET offers high sensitivity and specificity in the imaging of non-malignant extra-adrenal paraganglioma (PGL) and pheochromocytoma (PHEO) but lower sensitivity in metastatic disease. These tumours are of neuroendocrine origin and can be detected by 68Ga-DOTA-Tyr3-octreotide (68Ga-DOTA-TOC) PET. Therefore, we compared 68Ga-DOTA-TOC and 18F-DOPA as radiolabels for PET/CT imaging for the diagnosis of metastatic extra-adrenal PGL and PHEO. Combined cross-sectional imaging was the reference standard. METHODS: A total of 6 men and 4 women (age range 22-72 years) with anatomical and/or histologically proven metastatic PGL and PHEO were included in this study. Of these patients, 2 male patients suffered from PHEO, while the remaining 8 patients were diagnosed as metastatic extra-adrenal PGL disease. Comparative evaluation included morphological imaging with CT and functional imaging with 68Ga-DOTA-TOC and 18F-DOPA PET. The imaging results were analyzed on a per-lesion basis. The maximum standardized uptake value (SUVmax) of each functional imaging modality in concordant tumour lesions was measured. RESULTS: Compared with anatomical imaging, the per-lesion detection rate of 68Ga-DOTA-TOC was 100% (McNemar, P<0.01), and that of 18F-DOPA PET was 82.3% (McNemar, P<0.8) in metastatic extra-adrenal PGL and PHEO. Overall, 68Ga-DOTA-TOC PET identified 67 lesions; anatomical imaging identified 62 lesions, and 18F-DOPA PET identified 56 lesions. The SUVmax (mean±SD) of all concordant lesions was 29.3±19.9 for 68Ga-DOTA-TOC PET and 12.3±9.1 for 18F-DOPA PET (Mann-Whitney U test, P<0.0001). CONCLUSION: 68Ga-DOTA-TOC PET offers the highest detection rate in metastatic extra-adrenal PGL and PHEO compared to 18F-DOPA PET and even to diagnostic CT, particularly in bone lesions. Combined functional/anatomical imaging (68Ga-DOTA-TOC PET/CT) enables exact tumour extension to be detected in these rare tumour entities, especially in the case of unclear anatomical correlation.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Di-Hidroxifenilalanina/análogos & derivados , Compostos Organometálicos , Paraganglioma Extrassuprarrenal/diagnóstico por imagem , Feocromocitoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
2.
Neurosurg Rev ; 41(1): 285-290, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28417213

RESUMO

Cervical corpectomies are increasingly used to treat degenerative, metastatic, inflammatory and traumatic multisegmental diseases. The postoperative results are thought to correlate mainly with the number of resected vertebral bodies. Thus, the aim of the study was to analyse complications and early outcome of these procedures to document the implant-related complications in order to set up a prospective clinical trial. Forty-five patients, who were treated in our department from 2011 to 2014 and who were available for a minimum follow-up of 1 year, were consecutively included in this retrospective evaluation. The median age was 61 (±11) years with a female to male sex ratio of 19 to 26, respectively. In these patients, cervical corpectomies (one-, two- and three-level procedures) were performed. The average number of resected levels was 1.2 levels. The intraoperative loss of blood (LOB), the red cell transfusions (rcT), the length of operation (LOO) and the usage of drains were investigated and correlated with intra- and postoperative complications. The mean LOO was 244 min (±68) with a mean LOB of 511 ml (±531). The overall complication rate was 22.9% (10 patients). Six patients (13.3%) had implant-related complications due to loosening and toggling of the screws and/or cage subsidence. Two patients (4.4%) had a postoperative haematoma and another two patients (4.4%) suffered from neurological deterioration due to an ongoing and severe myelopathic syndrome. All these patients received revision surgery. The average time from the first to revision surgery was 90 days. Cervical corpectomies still remain procedures with a high complication rate mainly represented by implant-related failures. These implant-related complications range from screw/plate loosening or toggling to graft dislocation with subsidence and might be associated with constructs extended to the C7 vertebral body. In our study population, the rate of implant failure was comparable to the literature, but not obviously correlated with the number of vertebral bodies resected. This may be attributed to the different disease entities. Thus, our results support the use of circumferential approaches for selected instability scenarios (metastatic or inflammatory diseases, kyphosis, osteoporosis, etc.) of one- and two-level corpectomies.


Assuntos
Vértebras Cervicais/cirurgia , Fixadores Internos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Adulto , Idoso , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Acta Neurochir (Wien) ; 159(6): 1159-1162, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28374147

RESUMO

BACKGROUND: Osteolytic lesions of the anterior aspects of C1 (lateral mass) are difficult to address in a minimally invasive fashion and are often treated by craniocervical instrumentation. METHODS: We report the feasibility and technical method of transoral vertebroplasty of the lateral mass of the atlas using image guidance and describe the workflow of the procedure. To our knowledge, there has not yet been a technical description of a transoral vertebroplasty using image guidance. RESULTS: Adequate positioning of the pedicle access needle using image guidance for addressing the lateral mass of C1 through a transoral, permuceous access can be achieved. CONCLUSIONS: With the assistance of image guidance, it is safe and feasible to access the lateral mass of the atlas. This constitutes a minimally invasive and fast alternative for introducing the bone needle to C1 rather than using a fluoroscopic device alone.


Assuntos
Atlas Cervical/cirurgia , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Assistida por Computador/métodos , Vertebroplastia/métodos , Fluoroscopia/métodos , Humanos , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Cirurgia Assistida por Computador/efeitos adversos , Vertebroplastia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...