Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroradiology ; 64(12): 2363-2371, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35695927

RESUMO

PURPOSE: The natural evolution of unruptured intracranial aneurysms (UIA) is indeed difficult to predict at the individual level. OBJECTIVE: In a large prospective multicentric European cohort, we aimed to evaluate whether the PHASES, UCAS, and ELPASS scores in patients with aneurysmal subarachnoid hemorrhage would have predicted a high risk of aneurysmal rupture or growth. METHODS: Academic centers treating patients with intracranial aneurysms were invited to prospectively collect de-identified data from all patients admitted at their institution for a subarachnoid hemorrhage-related to intracranial aneurysmal rupture between January 1 and March 31, 2021 through a trainee-led research collaborative network. Each responding center was provided with an electronic case record form (CRF) which collected all the elements of the PHASES, ELAPSS, and UCAS scores. RESULTS: A total of 319 patients with aneurysmal subarachnoid hemorrhage were included at 17 centers during a 3-month period. One hundred eighty-three aneurysms (57%) were less than 7 mm. The majority of aneurysms were located on the anterior communicating artery (n = 131, 41%). One hundred eighty-four patients (57%), 103 patients (32%), and 58 (18%) were classified as having a low risk of rupture or growth, according to the PHASES, UCAS, and ELAPSS scores, respectively. CONCLUSION: In a prospective study of European patients with aneurysmal subarachnoid hemorrhage, we showed that 3 common risk-assessment tools designed for patients with unruptured intracranial aneurysms would have not identified most patients to be at high or intermediate risk for rupture, questioning their use for decision-making in the setting of unruptured aneurysms.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Hemorragia Subaracnóidea/diagnóstico por imagem , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Prospectivos , Aneurisma Roto/diagnóstico por imagem , Fatores de Risco
2.
AJNR Am J Neuroradiol ; 42(8): 1479-1485, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34117022

RESUMO

BACKGROUND AND PURPOSE: Woven EndoBridge (WEB) devices are increasingly used to treat intracranial aneurysms. A1 asymmetry contributes to anterior communicating artery aneurysm formation and to treatment instability after coiling. We sought to evaluate whether A1 asymmetry had an impact on angiographic outcome in anterior communicating artery aneurysms treated with the WEB. MATERIALS AND METHODS: Anterior communicating artery aneurysms treated between July 2012 and July 2020 with the WEB from an institutional review board-approved database were reviewed. A1 asymmetry was categorized as the following: absence of the A1 segment on 1 side (unilateral A1) versus bilateral A1. Univariate and multivariable analyses assessed independent predictors of adequate (WEB Occlusion Scale A, B, and C) and complete occlusion (WEB Occlusion Scale A and B). RESULTS: Forty-eight individual aneurysms (47 patients) were included in the final analysis, of which 16 (33%) were acutely ruptured. The mean size was 6.5 (SD, 2.2) mm. Adequate and complete occlusion was achieved in 33 (69%) and 30 (63%) cases, respectively. Unilateral A1 was associated with significantly higher rates of adequate (92% versus 60% for bilateral A1; P = .03) and complete occlusion (92% versus 50% for bilateral A1; P < .01). Multivariable logistic regression confirmed unilateral A1 as an independent predictor of both adequate (OR = 10.6; 95% CI, 1.6-220.7; P = .04) and complete occlusion (OR = 9.5, 95% CI, 1.5-190.2; P = .04. A sensitivity analysis comparing unilateral "functional" A1 with bilateral "functional" A1 showed similar results. WEB shape modification was not influenced by the unilateral A1 configuration (P = .70). CONCLUSIONS: Anterior communicating artery aneurysms with a unilateral A1 configuration treated with WEB devices are associated with better angiographic outcome than those with bilateral A1. This finding supports the hypothesis that WEB devices are resistant to unilateral flow in the aneurysm as opposed to coils.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 42(7): 1276-1281, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33926902

RESUMO

BACKGROUND AND PURPOSE: The Woven EndoBridge has proved to be a safe and effective treatment, especially for wide-neck intracranial aneurysms. The recent fifth-generation Woven EndoBridge came with smaller devices. The purpose of this study was to assess the safety and efficiency of Woven EndoBridge treatment of small and very small aneurysms. MATERIALS AND METHODS: Between September 2017 and March 2020, all consecutive patients treated with a 3- or 3.5 mm-width Woven EndoBridge device were included in this retrospective intention-to-treat study. Clinical and radiologic findings were evaluated at immediate and last-available follow-up. Angiographic outcome was assessed by an external expert reader. RESULTS: One hundred twenty-eight aneurysms were treated with a fifth-generation Woven EndoBridge device including 29 with a width of ≤3.5 mm. Ten aneurysms were ruptured (34%). In 3 cases (10%), Woven EndoBridge treatment could not be performed because the aneurysm was still too small for the smallest available Woven EndoBridge device and another endovascular strategy was chosen. The median follow-up time was 11.2 months. Complete and adequate occlusion was obtained in 71% and 90% of the treated aneurysms, respectively. Retreatment was needed in 2 cases (10%). Symptomatic ischemic complications leading to transient neurologic deficits occurred in 2 cases (7%) (1 procedure-related and 1 device-related) but with full spontaneous recovery at discharge. CONCLUSIONS: The fifth-generation Woven EndoBridge device seems to be a safe and technically feasible treatment for both ruptured and unruptured small and very small intracranial aneurysms, with satisfactory occlusion rates on midterm follow-up. However, further study is needed to evaluate longer-term efficiency.


Assuntos
Aneurisma Intracraniano , Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...